STEP 9.  SETTING THE CONTROLLER

(If adjustments are required.  Note factory defaults for program shown in Quick Reference Chart.)
Press the Enter/Exit button on the controller to turn on the LCD screen.  The first screen you will see is the visual battery

strength indicator (Fig. 11).  After 5 seconds, this will default back to the Main Menu screen, where the following features

can be found.  Starting with the top feature:

RUN-ON TIME 

                       Water flow stops at the selected run-on time after the user removes hands from the sensing zone.  Run-on

                       selection times are 0 to 8 seconds or 1 to 8 minutes for scrub-up applications.  Run time is factory set to 0

                       seconds.  Note: If the user activates the faucet before the run time expires, the faucet will continue to operate

                       and reset when their hands are removed again.

RESPONSE TIME 

                       Response time is the amount of response time it takes for the sensor to react to hands placed in the sensing

                       zone.  The factory default is 4 pulses per second (Standard).  This can be decreased to 2 pulses per second

                       (Slow) to save battery life or increased to 8 pulses per second (Fast) for maximum response.  Note: Using 8

                       pulses per second will significantly reduce battery life.  This feature is most beneficial when the controller is

                       hardwired.

BLOCK TIME (1-8 SECONDS)

                       The blocking time is the amount of time required between uses.  This prevents the faucet from activating again

                       until the blocking time has expired.  The default value is 1 second.  The blocking time moves up in 1-second

                       increments, up to 8 seconds max.

BATTERY STRENGTH INDICATOR

                       Displays the current state of the batteries.  The visual battery icon will appear “full” when batteries are still

                       healthy.  As the batteries drain, the battery icon will appear more and more depleted.  The word next to the

                       battery icon will give a quick synopsis of the battery strength (i.e. Healthy, Average, Poor Health).  When the

                       batteries have depleted to a point where they no longer can operate the solenoid, the battery strength indicator

                        will read “REPLACE!”  At this time, the controller will beep every time an object is sensed, but will not operate

                       the solenoid.  Replace the batteries immediately when this happens. 

SENSE RANGE (3” - 15”)

                       The sensor range is the maximum distance at which the user is detected.  The sensor range includes 3”, 6”,

                       8”, 10”, 12” and 15”.  The gooseneck product default value is 10”.  Note: Sensor 1” subject to environ-

                       mental conditions.

METERING MODE

A                     This allows for a continuous flow for a set amount of time, regardless of how long an object is placed in front of

                        the sensor.  Metered program is selectable from 7 to 240 seconds (when enabled) of continuous operation.  It

                        is factory set to Disabled.

 

  

ADDITIONAL FEATURES

Buzzer

:  Allows the user to turn ON or OFF the audible buzzer.  Factory set to ON.

Language:

  Allows the user to set their desired language of the controller; either English or French.  Factory set to English.

Diagnostics:

  Controller logs and displays Average usage per day, as well as Average Time-On of the faucet and Total

Faucet Activations to Date.

Set Defaults:

 

 This option is found in the Diagnostics Menu.  Selecting this feature resets all previously altered settings (i.e.,

Sense Time, Run-On Time) and sets them back to their initial default value.

Self-Test:

  Used to help troubleshoot the electronics.  It helps test out the features of your electronic faucet - like the

solenoid, sensor, 3-position switch feature and more.

w w w . s p e c s e l e c t . c o m

Содержание 300 T3 A Series

Страница 1: ...60906A Surface Mount Housing 060989A Controller 061256A 36 Cable Extension RP30523 Braided Hose 060683A 24VAC to 6VDC Converter 063127A Solenoid Valve with 3 8 Compression Connectors 060908A Solenoid...

Страница 2: ...older After the batteries are installed make the sensor connection on the controller neatly inside the battery box Connect battery clip to battery pack The blue backlit LCD screen will power up and th...

Страница 3: ...g on installation the cable bushings included may be replaced by installer supplied 1 2 conduit Rough in box as per Figure 8 The transformer is to be installed in an adjacent accessible space Do NOT i...

Страница 4: ...nal on solenoid valve black solenoid cord to other solenoid terminal INSTALLATION AND SET UP INSTRUCTIONS Valve Spacer replace with SOLENOID valve after system is flushed Cover Solenoid Valve INSTALL...

Страница 5: ...r will detect hands in the wash area Sensor Range Not Adjustable 1 minute Run On time The auto timer is the length of time before the faucet stops running in the event that the sensor is obstructed by...

Страница 6: ...l battery icon will appear full when batteries are still healthy As the batteries drain the battery icon will appear more and more depleted The word next to the battery icon will give a quick synopsis...

Страница 7: ...no opening closing click 2C Replace solenoid valve with 063127A or 060671A 2A Ensure that the water lines have been connected to the solenoid valve properly Arrow marking on body indicating water flow...

Страница 8: ...s warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Ca...

Отзывы: