209491   Rev. B

FOR RECESS MOUNT HOUSING: CONTROL BOXES #1 & 8

STEP 1. ROUGH IN

STEP 2. FAUCET INSTALLATION

 

   

INSTALLATION AND SET UP INSTRUCTIONS

Installation should be in accordance with local plumbing and electrical codes.

FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 

COVERS

060577A

12” Stainless Steel Cover

060073A

Screws (4/pkg) & driver bit for covers

TMV Repair Kits

061137A

Adjustment Wrench

Clean deck/sink surface where faucet will

be mounted.  Mount faucet to sink using

nut(s) and washer(s) provided.  Installation

of the single hole deck gasket (060564A)

between the turret base and mounting

surface is the recommended assembly

practice.  Ensure that gasket is sitting flat

on the deck and the turret is centered on

the gasket.  Use the same procedure for

installation of optional 4” or 8” deck plate

package (060546A or 060547A).  Mount

the faucet to the sink using nut(s) and

washer(s) provided.  Do not overtighten

the nut (RP6087) or reposition the turret

once installed, otherwise damage to the

gasket may result.  Cutting or trimming of

the gasket is not recommended.

NOTE: If the gasket is trimmed or not

installed, then use clear silicone sealant

between the faucet and lavatory to

prevent water from leaking beneath

lavatory.

w w w . s p e c s e l e c t . c o m

Note:

 Wires connecting between box(es) and from transformer must be protected from abrasion, and being pulled at connections.  They

also may have to be fished through at a later stage of construction.  Depending on installation, the cable bushings included may be

replaced by 

installer supplied

 1/2” conduit.  Rough-in box as per Figure 8.

The transformer is to be installed in an adjacent accessible space.  (

Do NOT install the transformer inside the control box.)

  Cable

from the transformer to the driver board/controller may be roughed in at this time depending on installation.  Use cable which complies to

local electrical codes for a 1 amp load.  No. 18 is usually sufficient.

HARDWIRE OR BATTERY

:

 

 If recessed box is supplied, rough in as per Figure 8.  The most vandal resistant installation is when the

control box is as close to the bottom of the sink as feasible.  For wall hung sink installation, sensor conduit rough in should be directly

under the basin to minimize sensor cord exposure.  Rough in drainage.  Rough in water supply to 10” control box inlets and to spout

connection.  Finish walls.
Valve spacer is for temporary use, only for flushing of system. Must be replaced with solenoid and washers (Fig. 6 & 7).

063164A

Check Valves (2/pkg)

Control Box #1

Fig. 6

Tempered Water

(By Others) 

Inlet: 1/2” Sweat

063135A

Stop Kit 

Battery holder

not required

for hardwire

models

060989A

3000T

Controller

Board to

be located

on bracket

060671A

3/4” NPS

Solenoid

Valve &

Washers

Flexible Sensor

Cord Conduit

(supplied on Recessed

Mount Box)

1/2” Sweat

Outlet

Bracket &

battery holder

not required

for hardwire

models

Control Box #8

Fig. 7

060989A

3000T

Controller

Board

to be

located

on

bracket

Hot Inlet

1/2” Sweat

1/2” Sweat

Outlet

Cold Inlet

1/2” Sweat

063179A

Thermostatic Mixing Valve

with checks & gaskets 

063135A

Stop Kit

063135A

Stop Kit 

Flexible Sensor

Cord Conduit

(supplied on Recessed

Mount Box)

Содержание 300 T3 A Series

Страница 1: ...60906A Surface Mount Housing 060989A Controller 061256A 36 Cable Extension RP30523 Braided Hose 060683A 24VAC to 6VDC Converter 063127A Solenoid Valve with 3 8 Compression Connectors 060908A Solenoid...

Страница 2: ...older After the batteries are installed make the sensor connection on the controller neatly inside the battery box Connect battery clip to battery pack The blue backlit LCD screen will power up and th...

Страница 3: ...g on installation the cable bushings included may be replaced by installer supplied 1 2 conduit Rough in box as per Figure 8 The transformer is to be installed in an adjacent accessible space Do NOT i...

Страница 4: ...nal on solenoid valve black solenoid cord to other solenoid terminal INSTALLATION AND SET UP INSTRUCTIONS Valve Spacer replace with SOLENOID valve after system is flushed Cover Solenoid Valve INSTALL...

Страница 5: ...r will detect hands in the wash area Sensor Range Not Adjustable 1 minute Run On time The auto timer is the length of time before the faucet stops running in the event that the sensor is obstructed by...

Страница 6: ...l battery icon will appear full when batteries are still healthy As the batteries drain the battery icon will appear more and more depleted The word next to the battery icon will give a quick synopsis...

Страница 7: ...no opening closing click 2C Replace solenoid valve with 063127A or 060671A 2A Ensure that the water lines have been connected to the solenoid valve properly Arrow marking on body indicating water flow...

Страница 8: ...s warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Ca...

Отзывы: