Page 1
209491 Rev. B
300__T3__ __ __A
Write purchase model number here for future reference
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
*Package Quantities May Change.
Check the Parts section of the latest Delta Commercial Faucet Price List for current quantities.
OPTION LIST
060637A
1.5 GPM (5.7 L/min)
VR Laminar Outlet with Agion
®
Antimicrobial
060639A
1.5 GPM (5.7 L/min)
VR Flow Control Aerator & Wrench
063191A (R3)
063193A (R5)
063194A (R7)
063195A (R35)
Single-Hole Mount
Assembly including
Sensor and Hold-Down
Package and Spout
with aerator thread
060564A
Single Hole Deck
Gasket (6/pkg)
RP6087
Nut & Washer
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
DECK PLATES
060546A
4” Deck Plate & Hold-Down Pkg
060547A
8” Deck Plate & Hold-Down Pkg
060681A
Battery Holder
Note:
See page 3 for parts breakdown
on recessed & surface mount boxes.
063254A
Deck Plate Nut & Washers
060546A
4” Deck Plate & Hold-Down Package
060547A
8” Deck Plate & Hold-Down Package
060564A
Single Hole Deck Gasket (6/pkg)
209491 209491 209491 209491
209491 209491 209491 209491
OR
060905A
Cover Gasket
060906A
Surface
Mount Housing
060989A
Controller
061256A
36” Cable
Extension
RP30523
Braided Hose
060683A
24VAC to 6VDC
Converter
063127A
Solenoid Valve with 3/8”
Compression Connectors
060908A
Solenoid Holder
060909A
Screen Assembly
063139A
0.5 USGPM
(1.9 L/min)
063140A
1.5 USGPM
(5.7 L/min)
Adapter with Flow
Control for smooth
end spouts
063131A
3/8” Comp Connect Nut
and Ferrile
w w w . s p e c s e l e c t . c o m
063128A
Battery Box Assembly less driver
board and battery holder
Outlet #7
1.5 USGPM (5.7 L/min)
063181A (R3)
063183A (R5)
063184A (R7)
063185A (R35)
Outlet #8
0.5 USGPM (1.9 L/min)
063186A (R3)
063188A (R5)
063189A (R7)
063190A (R35)
Single-Hole Mount
Assembly including
Sensor and Hold-Down
Package and Spout
(with smooth ends)
Fig. 1
NOTE:
Control Box #0 and #1 are designed for routine 171°F (77°C)
disinfection cycles up to 30 minutes.
Control Box #8 is not recommended for high temperature disinfection
cycles as the thermostatic mixing valve limits the higher temperature
flow output.
NOTE:
For optimum performance of this product, we recommend
a system pressure between 20 and 80 PSI static. This product
will operate up to a maximum of 125 PSI static per ANSI and CSA
requirements. However, we do not recommend pressure above
80 PSI. Thermal expansion or leaking pressure reducing valves
may require use of expansion tanks or relief valves to ensure
your system never exceeds its maximum intended pressure
setting.
061292A
3000T adaptor cable
*must order with spout RP