J6: General Purpose I/O
General purpose I/O is available on the Brick Motion Controller. All I/O is electrically isolated from the
drive. Inputs can be configured for sinking or sourcing applications. All Inputs are 12-24VDC. All
Outputs are 24V nominal operation, 0.5A maximum current. Outputs are robust against ESD and
overload.
J6 General Purpose I/O
(Female DB-37 Connector)
36
33
1
20
2
3
4
5
9
10
28
27
26
25
24
21
22
23
11
8
7
6
29
30
32
16
15
14
13
12
17
18
19
31
34
35
37
Pin #
Symbol
Function
Description
1 GPIN01 Input
Input
1
2 GPIN03 Input
Input
3
3 GPIN05 Input
Input
5
4 GPIN07 Input
Input
7
5 GPIN09 Input
Input
9
6 GPIN11 Input
Input
11
7 GPIN13 Input
Input
13
8 GPIN15 Input
Input
15
9
IN_COM 01-08
Input
Input 01 to 08 Common
10 N.C
Not
Connected
11
COM_EMT
Input
Common Emitter *
12
GP01-
Output
Sourcing Output 1 **
13
GP02-
Output
Sourcing Output 2 **
14
GP03-
Output
Sourcing Output 3 **
15
GP04-
Output
Sourcing Output 4 **
16
GP05-
Output
Sourcing Output 5 **
17
GP06-
Output
Sourcing Output 6 **
18
GP07-
Output
Sourcing Output 7 **
19
GP08-
Output
Sourcing Output 8 **
20 GPIN02 Input
Input
2
21 GPIN04 Input
Input
4
22 GPIN06 Input
Input
6
23 GPIN08 Input
Input
8
24 GPIN10 Input
Input
10
25 GPIN12 Input
Input
12
26 GPIN14 Input
Input
14
27 GPIN16 Input
Input
16
28
IN_COM_09-16
Input
Input 09 to 16 Common
29 COM_COL Input
Common Collector **
30
GP01+
Output
Sinking Output 1 *
31
GP02+
Output
Sinking Output 2 *
32 GP03+ Output
Sinking Output 3 *
33
GP04+
Output
Sinking Output 4 *
34
GP05+
Output
Sinking Output 5 *
35
GP06+
Output
Sinking Output 6 *
36
GP07+
Output
Sinking Output 7 *
37
GP08+
Output
Sinking Output 8 *
*For sinking outputs, connect the COM_EMT (pin11) line to the Analog Ground of the Power supply and the outputs to
the individual plus output lines, e.g. GPO1+
**For sourcing outputs, connect the COM_COL (pin29) line to 12-24V and the outputs to the individual minus output
lines, e.g., GPO1-
Do not mix topologies, i.e., all sinking or all sourcing outputs. If the common emitter is used, the common collector
should be unconnected. Conversely, if the common collector is used, the common emitter should be unconnected.
Содержание 5XX-603869-XUXX
Страница 4: ......
Страница 5: ...REVISION HISTORY REV DESCRIPTION DATE CHG APPVD 1 MANUAL CREATION 05 02 07 CP S MILICI ...
Страница 6: ......
Страница 14: ...Brick Motion Controller Hardware Reference Manual 6 Specifications ...
Страница 24: ...Brick Motion Controller Hardware Reference Manual 16 System Wiring Amplifier Fault Amplifier Enable diagrams ...
Страница 50: ...Brick Motion Controller Hardware Reference Manual 42 Appendix C Dimensional Layout and Connector location ...