background image

Quad Amp Hardware Reference Manual 

Installation  

25 

Grounding 

General 

It is important to follow some precautions to avoid ground loops or unwanted electrical noise disturbances. 

• 

All signal cables must be shielded. 

• 

Two or more power wires in the same sleeve must be twisted and shielded. 

• 

A shield that does not carry current can be connected at both ends 

• 

A cable with low power electrical signals should never run in the same proximity of high power cables. 

Main Power Supply (DC Bus) 

The Quad Amplifier chassis must be connected to earth (ground).  A ground screw, designated E on the 
Quad Amplifier, has been provided for this and is located on the top panel of the amplifier.  

Motor 

Each motor housing must be connected to Chassis Ground.  A Chassis Ground terminal is provided for each 
motor at the motor output terminal block.  Motor leads should be shielded to help avoid stray electrical 
noise and electrical radiation. 

PMAC2 I-Variables Setup 

Reference the PMAC2 Family Addendum to the PMAC User Manual and Software Reference for 
information on how to set up all the I-variables and other necessary parameters.  The preferred method for 
tuning the amplifier is to use the P2 Setup software package available from Delta Tau.  There are several 
PMAC2 I-variables we emphasize for proper operation of the Quad Amplifier. 

Ix00 

This parameter determines whether a motor is active (Ix00=1) or inactive (Ix00=0).  An active motor may 
be enabled (either in open or closed loop) or disabled, depending on commands or events. 

Ix01 

Must be set to 1 to enable commutation for any motor connected to the Quad Amplifier. 

Ix02 

Must contain the address of the A output register for the machine interface channel n used to connect to the 
amplifier.  Usually, channel number n equals motor number x.  The default values of Ix02 are valid when n 
= x. 

Ix25 

Must contain the address of the flag register for the machine interface channel n used to connect to the 
Amplifier.  The same interface channel number must be used for the flags and the command outputs! 
Default values for Ix25 are valid when n = x. 

Ix82 

Must contain the address of the B current feedback register for the machine interface channel n used to 
connect to the amplifier.  Usually, channel number n equals motor number x.  The default values of Ix82 are 
valid when n = x. 

I900 

I900 controls the maximum phase clock frequency for PMAC2 and the PWM frequency for machine 
interface channels 1-4.  Refer to PMAC2 Family Addendum to User Manual and Software Reference for 
further information.  If I900 is accidentally set above approximately 15 kHz, the Quad Amplifier will 
disable all enabled axes and the LED display will show a code 9.  

Содержание 3Ax-602646-xUxx

Страница 1: ...2 Quad Amp 3 4 Axis Digital Amplifier 4 3Ax 602646 xUxx 5 September 24 2003 Single Source Machine Control Power Flexibility Ease of Use 21314 Lassen Street Chatsworth CA 91311 Tel 818 998 2095 Fax 81...

Страница 2: ...ifiers contain static sensitive components that can be damaged by incorrect handling When installing or handling Delta Tau Data Systems Inc products avoid contact with highly insulated materials Only...

Страница 3: ...t Required 9 Installation Considerations and Options 9 Option 3 3A and 3B External Mount 9 Option 4 and 4A Internal Mount 9 THEORY OF OPERATION 11 Operation 11 Configuration 11 Logic Board 11 Current...

Страница 4: ...Ix82 25 I900 25 I9n6 26 Start Up Procedures 26 Power On Sequence 26 P2Setup 26 TROUBLESHOOTING 29 Logic Fault Detection and Fault Codes 29 Axis Specific Faults 29 Global Faults 29 Fault Reporting 29 S...

Страница 5: ...d Amp If any of these manuals are missing contact Delta Tau before attempting installation Manual Number Manual Title 3A0 602204 363 PMAC User Manual and Software Reference with PMAC2 Addendum 3A0 602...

Страница 6: ...ns 3 and 3A Customer supplied external Protection Fuses F201 Shunt Regulator IGBT and Shunt Resistors F202 Logic Power Supply 3 Phase In Line Circuit Breaker Optional Bus Supply Control Supply and Shu...

Страница 7: ...10 A 12 5 HP continuous output 25 A 25 HP continuous output 36 A 33 HP continuous output Frequency 50 60 Hz 2 Control AC Input Voltage Current Connector C3 Dependent on Option Ordered Input voltage Se...

Страница 8: ...AIR FLOW Figure 1 Quad Amp Specifications Output Specifications for 120 208 230 VAC Amplifier Up to four blocks options can be selected in any power combination The total power cannot exceed 33 HP No...

Страница 9: ...HP 67 kW Peak 2 sec current 5 A 12 A 15 A 21 A 36 A 54 A 75 A 100 A 150 A 200 A PWM dead time 2 3 s PMAC2default PMAC2 programmable Output Specifications for 380 460 VAC Amplifier Up to four blocks op...

Страница 10: ...when the shunt IGBT is turned off The diode is connected across the external shunt resistor terminals Fuses The primary hardware protection is fuses which are mounted within the Quad Amplifier chassi...

Страница 11: ...nt 307 QADAMP OPT Power Block Option 7 20 Amp 600V Block 2 HP Cont 308 QADAMP OPT Power Block Option 8 30 Amp 600V Block 3 HP Cont 309 QADAMP OPT Power Block Option 9 50 Amp 600V Block 5 HP Cont 310 Q...

Страница 12: ...sistor 4 25 Ohms 1400 Watts each 25 long 2 diameter Edge Power resistor Open Frame Two required for 208 230 Quad Amplifier Three required for 380 460 Quad Amplifier Connected in series 3AO 602775 10X...

Страница 13: ...e equipment which when installed and connected together constitute a typical Quad Amplifier System Figure 2 shows the interconnection of the Quad Amplifier System components Component Quantity Descrip...

Страница 14: ...built in shunt regulator with internal shunt resistors for small motor loads of under 10 HP To ensure long term reliability the ambient temperature of the cabinet should not exceed 45o C A X IS 1 A X...

Страница 15: ...word that tells the PMAC2 how many bits to expect from the A D converter The clock and the strobe for the digital feedback are programmable at the PMAC2 The position feedback in the form of quadratur...

Страница 16: ...operation of the Quad Amplifier Over voltage is set at 410 820 VDC and can be factory set lower with R2 If there is an absence of logic power 15V the split gate drive power supply will not be able to...

Страница 17: ...nt regulator with dumping resistors These are not sized for a particular load and may not be adequate for any particular application These internal shunt resistors are nominally capable of dumping 25...

Страница 18: ...Quad Amp Hardware Reference Manual Theory of Operation 14...

Страница 19: ...Amplifier channels 1 2 or 3 4 The following chart lists the possible combinations for proper Quad Amplifier operation Two Quad Amplifier Example PMAC Axes Quad AMP 1 Channels 1 2 Quad AMP 1 Channels...

Страница 20: ...ct the Acc 8F to the PMAC2 PC are provided with each Acc 8F Refer to the PMAC2 Acc 8F User Manual PWM Input Cables 36 inch PWM input cables Acc 8F Opt 5 are available from Delta Tau Data Systems Inc O...

Страница 21: ...U U U MOTOR CABLES AXIS 1 AXIS 2 AXIS 3 AXIS 4 MOTOR OVERTEMP CONNECTOR AXIS 1 AXIS 3 AXIS 4 AXIS 2 CONTROL AC VOLTAGE EXTERNAL GROUND FAULT TRIP E STOP READY BUS SHUNT BUS CHASSIS GROUND L3 L2 L1 OP...

Страница 22: ...B Bottom CMD 13 Pwmctop1 Input Phase C Top CMD 14 Pwmcbot1 Input Phase C Bottom CMD 15 Gnd Common Reference Voltage 16 Pmac_ 5 Input 5V Power 17 NC 18 NC 19 Fc_B1 Input 20 Fc_D1 Input 21 Clk0 Input A...

Страница 23: ...C3 is used for ground green wire If the input power requirements have changed since the Quad Amplifier order the Control Power Transformer T201 located under the Quad Amplifier cover must be reconfigu...

Страница 24: ...to pins 1 and 8 via AC input connector C3 For 480 VAC Operation Jump pin 4 to pin 5 and pin 8 to pin 9 Power is applied to pins 1 and 10 via AC input connector C3 Figure 8 120V 208V 230V Quad Amplifie...

Страница 25: ...rvo amplifiers Bus Filter Indicator The bus filter indicator board is mounted to the Bus and Bus power bars which are located between Axis 1 and 3 and Axis 2 and 4 output blocks inside of the Quad Amp...

Страница 26: ...5 15 V On when 15VDC logic power is present D6 5 V On when 5 VDC logic power is present D7 15 V On when 15 VDC logic power is present D14 AXIS 1 FLT On when Axis 1 faulted D15 AXIS 2 FLT On when Axis...

Страница 27: ...E4A IN Enable Serial Fault Data Phase A Open OUT E1B E4B IN Enable Serial Fault Data Phase B Open OUT E5 IN Clock Polarity 2 and 3 Jumpered OUT E6 IN Convert Polarity 2 and 3 Jumpered OUT LED Symbol D...

Страница 28: ...t point 2 75V 230VAC Main IGBT turns on at 80 of the nominal bus voltage Note Main and shunt set points are line sensitive and will vary with line voltage LED Symbol Description D25 L LOW Low Line on...

Страница 29: ...are several PMAC2 I variables we emphasize for proper operation of the Quad Amplifier Ix00 This parameter determines whether a motor is active Ix00 1 or inactive Ix00 0 An active motor may be enabled...

Страница 30: ...properly wired and grounded 3 Ensure the PMAC2 I variables are set as described above Power On Sequence 1 Ensure E Stop Plug C1 is wired to the normally open auxiliary switch of the Main AC Power Cont...

Страница 31: ...25 Enter Max ADC value in P2 Setup step Current Protection Enter Peak Current and Continuous Current values if applicable F A Q 1 PWM Frequency The default value suggested by P2Setup 4 5 kHz works wel...

Страница 32: ...Quad Amp Hardware Reference Manual Installation 28...

Страница 33: ...Fault Reporting Fault conditions are reported in two places First the on board current sense board LED displays the fault code as a hexadecimal digit Second the fault code is attached to the end of th...

Страница 34: ...imal point shall be lit if the internal shunt is active The LED fault indicator will provide a following common fault code for the Quad Amplifier 0 Everything O K 1 General firing module fault 2 Modul...

Страница 35: ...ved Motor does not turn 1 Is the correct main AC power applied to the unit Apply correct AC power 2 Is a motor connected Connect motor 3 Is the power enable E Stop switch closed at C1 Close E Stop swi...

Страница 36: ...IGBT and J4 5 6 Soft Start board is okay Then verify if G1 with respect to E1 switches from approx 10 VDC to 15 VDC after the Main power is turned on If it does the Main IGBT is probably open If it do...

Страница 37: ...n true manufacturer and true manufacturer part number if applicable for each CRU of the Quad Amplifier Replacement parts may be ordered from Delta Tau Data Systems Inc or by contacting the manufacture...

Страница 38: ...Quad Amp Hardware Reference Manual Illustrated Repair Parts List 34 Figure 12 Delta Tau Data Systems 4 Axis Digital Amplifier...

Страница 39: ...00V Used on 380 460 Quad Amplifier 1 Bussman FNQ 4 140 213 602647 100 Control PWR Trans 1 3s Indust 6000 63 1 150 005 580N40 3BR Bridge Rect 40A 800V for standard power supply 1 Powerex RM20TPM H 160...

Страница 40: ...raded power supply 1 Delta Tau 310 300 603000 100 Mov Assy 480VAC for high voltage power supply 1 Delta Tau 320 016 600V04 55A 4 Pos Terminal Blk 1 Marathon 1104S 330 016 MARA07 0TB 7 Pos Terminal Blk...

Отзывы: