Accessory
24E2A
Acc-24E2 Limit and Flag Wiring
The Acc-24E2 allows the use of sinking or sourcing position limits and flags to the controller. The opto-
isolator IC used is a PS2705-4NEC-ND quad photo-transistor output type. This IC allows the current to
flow from return to flag (sinking) or from flag to return (sourcing).
A sample of the positive limit circuit is shown below. The 4.7K resistor packs used will allow 12-24V
flag inputs. If 0-5V flags are used, then a 1K
Ω
resistor pack (RP) can be placed in either RP45 or RP46
(refer to the Resistor Pack Configuration section of this manual). If these resistor packs are not added, all
flags (
±
Limits, Home, User, and amplifier fault) will be referenced from 0-5V.
Connecting Limits/Flags to the Acc-24E2
The following diagram illustrates the sinking and sourcing connections to an Acc-24E2. This example
uses 12-24V flags.
10
Hardware Setup
Содержание 24E2A
Страница 3: ...REVISION HISTORY REV DESCRIPTION DATE CHG APPVD 1 ADDED CE DECLARATION 06 07 06 CP S FIERO...
Страница 4: ......
Страница 7: ...Accessory 24E2A DECLARATION OF CONFORMITY 52 SCHEMATICS 54 Table of Contents iii...
Страница 8: ......
Страница 28: ...Accessory 24E2A 20 Connections...
Страница 50: ...Accessory 24E2A 42 Acc 24E2 Terminal Block Description...
Страница 54: ...Accessory 24E2A 46 Acc 24E2 Option 1A Terminal Block Description...
Страница 58: ...Accessory 24E2A 50 Acc 24E2A DB15 Connector Option...
Страница 61: ...Accessory 24E2A Declaration of Conformity 53...
Страница 62: ...Accessory 24E2A SCHEMATICS 54 Schematics...
Страница 63: ...Accessory 24E2A Schematics 55 55...