DRFF-530R Screw Feeder
Operation and Setup Manual
www.deltaregis.com
14
12
Infrared Sensor
Voltage
Enters diagnostic mode and displays the DC
voltage of the infrared sensors ~0470 when open,
~5000 when screw present
(Program Value: 00: disable; 01 enable)
13
Screw Specification
Set according to the thickness of the screw head
(Program Value: 00: Large Screw; 01: Small Screw)
14
Brush Motor
Shutdown Delay
Set the delay time for the brush motor to stop
when screw present
(Program Value: 01-20 (1 second per unit))
15
Brush Motor Speed
Set the operating speed of the brush motor
(Program Value: 01-10 (01 min, 10 max))
NOTE:
1. Vibration motor shutdown delay value must never exceed brush motor shutdown
delay value in order to prevent screws from jamming at the screw head guide plate.
2. When Program 12 is enabled, the vibration and drum & brush motors will not run.
The turntable will rotate at minimum speed for several cycles before stopping. Once
the turntable has stopped, adjust the infrared sensors to display ~2500 for optimal
sensing. After the adjustment has been made, turn the machine off then on to
continue using the machine. Screws with a small headed may require a value greater
than 2500.
3. Program 13 is set based on the thickness of the screw head. If the screw head is
0.5mm or less, use 01. If the screw head is greater than 0.5mm, use 00.
Error Codes
Error Code
Description
E-01
Drum/Brush motor seized
E-02
Turntable motor seized
E-03
Drum/Brush motor not detected
E-04
Vibration motor not detected
E-05
Drum/Brush and Vibration motor not communicating