background image

DRFF-530R Screw Feeder

Operation and Setup Manual

www.deltaregis.com

14

12

Infrared Sensor 

Voltage

Enters diagnostic mode and displays the DC 

voltage of the infrared sensors ~0470 when open, 

~5000 when screw present

(Program Value: 00: disable; 01 enable)

13

Screw Specification

Set according to the thickness of the screw head

(Program Value: 00: Large Screw; 01: Small Screw)

14

Brush Motor 

Shutdown Delay

Set the delay time for the brush motor to stop 

when screw present

(Program Value: 01-20 (1 second per unit))

15

Brush Motor Speed

Set the operating speed of the brush motor

(Program Value: 01-10 (01 min, 10 max))

NOTE:

1. Vibration motor shutdown delay value must never exceed brush motor shutdown 

delay value in order to prevent screws from jamming at the screw head guide plate.
2. When Program 12 is enabled, the vibration and drum & brush motors will not run. 

The turntable will rotate at minimum speed for several cycles before stopping. Once 

the turntable has stopped, adjust the infrared sensors to display ~2500 for optimal 

sensing. After the adjustment has been made, turn the machine off then on to 

continue using the machine. Screws with a small headed may require a value greater 

than 2500.
3. Program 13 is set based on the thickness of the screw head. If the screw head is 

0.5mm or less, use 01. If the screw head is greater than 0.5mm, use 00.

Error Codes

Error Code

Description

E-01

Drum/Brush motor seized

E-02

Turntable motor seized

E-03

Drum/Brush motor not detected

E-04

Vibration motor not detected

E-05

Drum/Brush and Vibration motor not communicating

Содержание DRFF-530R

Страница 1: ...n this manual before using a DRFF screw feeder If you have any questions or concerns please contact us at Delta Regis Tools Inc Ph 1 772 465 4302 7370 Commercial Circle Fx 1 772 465 4368 Fort Pierce F...

Страница 2: ...r The screw feeder rail must be kept free from oil grease dust or any other contaminates Do not place you hand or any foreign objects into the screw hopper when the unit is running In the event that t...

Страница 3: ...This machine has been set up according to the sample fasteners and ortechnicaldrawingyouhadprovidedusduringyourpurchase Iffine tuning is required please follow the instructions starting on page 5 2 5...

Страница 4: ...peration and Setup Manual www deltaregis com 4 Product Overview 1 Rail Gates 2 Power Switch 3 Screw Present Error LED 4 Programming Key Pad w LCD 5 DC Receptacle 6 Grounding Lug ESD Applications 7 I O...

Страница 5: ...al www deltaregis com 5 User Adjustments Screw Guide Plate 1 Locate and loosen highlighted screws using a 2mm hex key 2 Using the included shims insert under the screw head guide press down on the pla...

Страница 6: ...everal screws into the rail assembly Tilt the screw feeder forward ensure the screws can smoothly pass under the guide plate NOTE When adjusting the screw guide plate the screws from step 1 must be fu...

Страница 7: ...is com 7 Infrared Sensor Adjustment Continued 2 Adjust the infrared openings so only half of the opening is exposed tighten screws from step 1 NOTE Only half of the infrared opening can be exposed If...

Страница 8: ...DRFF 530R Screw Feeder Operation and Setup Manual www deltaregis com 8 User Adjustments Brush Adjustment 1 Loosen the highlighted screws using a 2 5mm hex key...

Страница 9: ...several screws into the rail under the brush Manually sweep the brush across the screw heads Adjust the brush so slightly touches the screw heads Re tighten the screws from step 1 NOTE The brush hold...

Страница 10: ...e hopper cover Check for debris or foreign objects Fill the hopper with screws leaving a minimum of 2 mm space under the rail for thread lengths up to 5mm 4mm space for thread lengths over 5mm The hop...

Страница 11: ...orientation move the screwdriver s bit to the bit guide slide down the guide to the screw head momentarily start the screwdriver to engage the bit with the screw and pull the screwdriver away from the...

Страница 12: ...s the OK key to enter the value under this program Currently the first two digits of the display are solid and the last two digits are flashing Short press the UP or DN key to set the program value 3...

Страница 13: ...gram Value 01 20 1 second per unit 05 Vibration Motor Speed Set the operating speed of the vibration motor Program Value 01 20 01 min 20 max 06 Drum Motor Shutdown Delay Set the delay time for the dru...

Страница 14: ...r shutdown delay value in order to prevent screws from jamming at the screw head guide plate 2 When Program 12 is enabled the vibration and drum brush motors will not run The turntable will rotate at...

Страница 15: ...perly closed and remove all screws from inside the machine Infrared sensors misaligned Adjust the alignment of the sensors see page 7 14 Infrared sensors blocked Clear obstruction and or clean sensors...

Страница 16: ...y PCB damaged or wire disconnected 1 Use a voltmeter set to ohms Circuit is open when no screw present circuit is closed when screw present 2 Reconnect wire to PLC and or relay PCB Main PCB damaged or...

Страница 17: ...ely Rail cleaning maintenance Using a lint free swab dipped in alcohol clean the inner rail surfaces clean the rail s sliding surface very well as to remove any debris or oil Cleaning and maintaining...

Страница 18: ...l and workmanship This warranty does not cover damage due to transportation abuse misuse modification or improper service Our sole remedy is to repair or replace at our discretion any unit found to be...

Страница 19: ...elta Regis Applicable Models DRFF 530R DRFF 530 DRFF 630C The undersigned hereby declares on behalf of Delta Regis Tools Inc that the product designated in this declara on is in conformity with the pr...

Отзывы: