DRFF-530 Screw Feeder
Operation and Setup Manual
www.deltaregis.com
13
NOTE:
Normal Mode = Accumulative Count
Counter Mode = Batch Count
Program
Program Name
Program Description (set by using UP/DN)
01
Fastener Count
Set the target number of fasteners to count
(Program Value: 00-99 (00 disables Counter
Mode))
02
Counting Method
Set the counting method of Program 01 - Must
have a value set for Program 01 & Counter Mode
enabled
(Program Value: 00: increase; 01: decrease)
03
Buzzer
Turn the buzzer on or off
(Program value: 00: OFF; 01 ON)
04
Vibration Motor
Shutdown Delay
Set the delay time for the vibration motor to stop
when screw present
(Program Value: 01-20 (1 second per unit))
05
Vibration Motor
Speed
Set the operating speed of the vibration motor
(Program Value: 01-20 (01 min, 20 max))
06
Drum Motor
Shutdown Delay
Set the delay time for the drum motor to stop
when screw present
(Program Value: 01-20 (1 second per unit))
07
Drum Motor
Speed
Set the operating speed of the drum motor
(Program Value: 01-10 (01 min, 10 max))
08
Turntable Motor
Speed
Set the operating speed of the turntable motor
(Program Value: 01-10 (01 min, 10 max))
09
Vibration Motor
Rotation
Set the direction of the vibration motor
(Program Value: 00: CW Rotation; 01: CCW
Rotation)
10
Drum Motor Pause
Set the number of counted fasteners to start the
drum motor
(Program Value: 00-20 (00 disable))
11
Turntable Motor
Start Delay
Set the delay time for the turntable motor to start
(Program Value: 01-10 (0.5 seconds per unit))