DRFF-530 Screw Feeder
Operation and Setup Manual
www.deltaregis.com
12
Programming
LCD Display & Programming Keys
1. In any state, long press the SET button for 3 seconds, the system enters
programing mode, the SET light illuminates, and the program selection is
activated. Currently, the first two digits of the display are flashing, and the last
two digits are steady to display the program value under this program. Short
press the UP or DN key to select the program to be adjusted.
2. After selecting the program to be adjusted, short press the OK key to enter
the value under this program. Currently, the first two digits of the display are
solid, and the last two digits are flashing. Short press the UP or DN key to set
the program value.
3. After the program value has been set, short press the OK key to exit the
setting under this item and return to the program selection.
4. When finishing programming, wait 3 seconds to auto-exit programming
mode.
5. To reset the total screw count: long press the SET key and OK key at the same
time, the total count will be reset to zero.
6. Normal Mode and Counter Mode can be switched by pressing “OK”. Program
01 must have a value of 01 or greater to enable switching between these
modes. A value of 00 will only allow Normal Mode to function.