BECT832-SSO  Screwdriver Controller

Program Options and Editing

DELTA REGIS

Tools Inc.

SEQUENCE NUMBER (SL)

There are 5 programmable screw fastening sequences (SL=’U1’ to ‘U5’) available. In many cases, only the first 

sequence (U1) will be needed. If the screwdriver is used to install a batch of fasteners with varying requirements, 

multiple sequences may be necessary. For example, if an assembly requires the installation of 4 screws, where 

3 screws are short and 1 screw is long, the controller can be programmed with 2 unique sequences - a sequence 

for the short screws and one for the long screws. This would allow different time windows to be set-up for the two 

different screw lengths. Each sequence must be programmed separately, and numbered in the order that the screws 

will be installed (starting with Sequence U1). In this example, if the 3 short screws are to be installed first, enter 

the program for Sequence ‘U1’ with a batch quantity of 3 and time parameters for the short screw. Then repeat the 

program steps for Sequence ‘U2’ with a batch quantity of 1 and the time parameters for the long screw. Finally, 

program Sequence ‘U3’ with a batch quantity of ‘00’ to signify that there are no further fasteners to install. 

(For multiple sequences, refer also to info on setting dip switch #6 on pg. 13).

BATCH COUNT SETTING (SC)

Enter the desired number of fasteners to be installed per batch. Depending on the setting of DIP switch #1, the 

display will either count down from the total batch value entered, or count up to the total batch value. The count will 

only increment (and indicate a ‘GOOD’ rundown) if the rundown cycle falls within the limits set by the min and max 

rundown time settings (see below). When all fasteners in the batch have been installed, the controller will indicate that 

the batch is complete and the count will reset for the next cycle.

If, after a good rundown, the operator runs the screwdriver in reverse, the batch count value will decrement by a 

count of one (based on the assumption that the operator is removing the last installed fastener).

The batch count can be reset to begin a new batch by pressing the ON/CLEAR key.

END OF BATCH RESET TIME (Rt)

When a rundown batch is completed, the controller provides a visual indication (count = ‘00’) and audible indication 

(depending on audible settings) that the batch is complete, followed by a reset of the display count for the beginning 

of the next batch. The END OF BATCH RESET TIME value determines how long these indicators will stay on before 

the batch count resets. Please note that the screwdriver cannot be operated during this reset time period.

SLOW START TIME (RC) and SLOW START SPEED (SP)

Please refer to the section entitled ‘Screwdriver Speed Adjustments’ for further information on the Slow Start function.

MAXIMUM AND MINIMUM RUNDOWN TIME SETTINGS (Ht, Lt)

The controller determines whether a fastener rundown is deemed GOOD (OK) or NO GOOD (NG) by comparing the 

actual time taken for the rundown cycle to a time window programmed by the user. For example, a cross threaded 

screw will cause the screwdriver to shut-off too early (before min time) and a stripped screw will cause the driver to 

run too long (beyond max time). 

Cycle

Start

MIN Time

MAX Time 

NO GOOD (NG)

GOOD (OK)

NO GOOD (NG)

If the fastening cycle completes (clutch trips) within the programmed time window, the 

rundown cycle will be accepted as GOOD (OK) and the batch count will increment.

Time (seconds)

RECONFIRM TIME (LL)

If the assembly process requires that the operator has the ability to ‘double-hit’ the fastener (release and retrigger the 

screwdriver on a fastener that has just been installed), a reconfirm time can be programmed into the control. During 

this time period (which immediately follows the completion of the rundown), the operator is able to re-trigger the tool 

without causing a No Good (NG) error signal to be generated. Slow start time (RC) must be set to a value of ‘0.0’ for 

this function to be available, so that the tool has full power to run the re-hit cycle.

www.deltaregis.com

 

Page 6

Содержание BECT832-SSO

Страница 1: ...ively with the following Delta Regis Brushless Electric Screwdrivers CESL810 812 CESL823 F P PF CESL824 F P PF CESL827 P Do not attempt to use this controller with any other tools If you have any questions or concerns please contact us at Delta Regis Tools Inc 6945 LTC Pkwy Port St Lucie FL 34946 USA Ph 1 772 465 4302 Fx 1 772 465 4368 E mail sales deltaregis com Website www deltaregis com Doc BEC...

Страница 2: ...maximum current rating an internal fuse will disrupt power Should the controller stop functioning or exhibit abnormal or intermittent operation please discontinue use immediately and send the controller to an authorized service centre for troubleshooting and repair 11 Excessive duty cycle will cause the tool and or controller to overheat If this occurs discontinue use until cooled down and reduce ...

Страница 3: ...unt Setting Range rundowns batch 1 99 Time Window Settings Minimum acceptable rundown time 0 00 9 90 seconds 0 01 sec increments Maximum acceptable rundown time 0 0 9 9 seconds 0 1 sec increments Audible Alarm Settings selectable On sounds when Good No Good Batch Complete OF sounds when No Good FF sounds when Batch complete No Good EF sounds when Good Batch Complete Input Connections Remote Start ...

Страница 4: ...E RECEPTACLE AND MAIN POWER ON OFF SWITCH SCREWDRIVER CABLE CONNECTOR SCREWDRIVER HI LO SPEED SELECTOR INPUT OUTPUT CONNECTION TERMINAL BLOCK DIP SWITCH FOR SELECTING OPTIONAL FUNCTIONS Page 4 Front Face of Controller Rear Panel of Controller KEYPAD AND INDICATORS FOR PROGRAMMING AND STATUS MONITORING PROGRAM FUNCTION KEY LOCK ...

Страница 5: ...ctor switch from HI to LO will toggle between the two available speeds voltages Keypad and Programming Basics Page 5 ON CLEAR KEY Pressing and holding the ON button for 5 seconds will cause the display to go blank In this mode the screwdriver will function at HI LO speed but there will be no other functionality counting slow start etc Pressing ON from this mode will restore the display and added f...

Страница 6: ...verse the batch count value will decrement by a count of one based on the assumption that the operator is removing the last installed fastener The batch count can be reset to begin a new batch by pressing the ON CLEAR key END OF BATCH RESET TIME Rt When a rundown batch is completed the controller provides a visual indication count 00 and audible indication depending on audible settings that the ba...

Страница 7: ... a value lower than High Time Ht during programming or an error Er will occur Ht value must be Lt SEQUENCE LIST 5 available sequences PressandholdSELECT forabout5seconds until SL displays Releaseto view programmedvalue SEQUENCE U1 U5 select to edit Adjustvalue UP DOWN Pressuntil SC displays Releaseto viewvalue Adjustvalue UP DOWN SCREW BATCH COUNT of screws per batch MIN 00 screws MAX 99 screws Pr...

Страница 8: ... is only available if Slow Start Time RC is set to 0 0 slow start off The re hit function can t be used in conjunction with slow start nS Disable Screwdriver on NG If nS is set to y yes the screwdriver will be disabled after a no good NG rundown The operator must confirm by pressing the SELECT key or an external confirm signal must be input through the I O applies to forward cw rotation only rt Au...

Страница 9: ...h tt until the operator runs the driver and completes the batch Only one of the two optional alarms can be selected for use Page 9 MAX STANDBYTIME BETWEEN RUNDOWNS Time seconds Range 00 99 Pressuntil dt or tt displays Releaseto viewvalue Adjustvalue UP DOWN MAX TOTAL BATCH TIMEWARNING Time minutes Range 00 99 Adjustvalue UP DOWN n no y yes Togglevalue GATE SWITCH INPUT PREFERRED LOGIC Hi Lo Toggle...

Страница 10: ...further details on entering parameters Audible Alarm Settings OK and NG Lights Along with the two digit count display the controller also provides visual and audible indication of rundown OK rundown NG and batch complete The OK green and NG red lamps indicate whether the rundown was GOOD or NO GOOD If the rundown is within the set parameters the OK lamp will light up at the end of the rundown cycl...

Страница 11: ...external confirmation that the process can continue see DIP SW3 description OFF ON OFF ON OFF ON OFF ON Page 11 Output Terminals OUTPUT TERMINALS 2 thru 7 Connection pairs 2 3 4 5 and 6 7 are dry relay contact outputs AC DC 40V 250mA max INPUT TERMINALS 8 thru 13 COM 14 Connect an external switch between COM terminal 14 and the input terminal 8 13 Use a separate switch contact for each required in...

Страница 12: ... the previous batch Placing SW3 in the ON position will require the operator to press the SELECT button or require an external CONFIRM input at the end of each batch before the controller will reset to run a new batch Upon batch completion the display will flash C3 and the screwdriver will be disabled until the SELECT button is pressed or a CONFIRM signal is input SW 4 Multiple External Switch Inp...

Страница 13: ...urther details on speed settings 7 Press SELECT The display shows 0 0 The tool is now ready to run tests Use the screwdriver to rundown the fastener on the application The display will count up time in 0 1 second increments until the cycle completes Once complete the cycle time will show in the display Repeat the rundown as many times as desired 8 Move SW5 to the OFF position The controller will p...

Страница 14: ...utch E7 FWD REV Switch Error Controller detected a change in the position of the FWD REV switch while the tool was running FWD REV Button was moved by the operator during rundown switch PCB improperly positioned in tool housing or magnetic switching element has failed E8 Brake Error Controller detected an abnormal brake clutch signal before the tool was started clutch is stuck at the top of the cl...

Страница 15: ...t max time value The BECT832 SSO Controller is not user serviceable Any repairs must be performed by a Delta Regis authorized service center Please consult Delta Regis Tools for further information and the location of the nearest authorized service center Repairs to brushless DC screwdrivers must be performed by trained personnel knowledgeable and qualified in the repair of DC electric screwdriver...

Отзывы: