7

2.2 Configuring the IC650 Charger Using a USB Flash Drive

Using the Delta-Q software, USB storage drives can be pre-programmed to certain charger configurations. 

To use the USB port, follow these steps:

1.  Insert the USB flash drive at any time, but preferably not during a charge cycle. Stop the charge cycle by 

removing AC power or the DC connection to the batteries. The charger can power the USB port from the 

AC connection (DC disconnected) or from the DC connection (AC disconnected).

2.  If there is enough disk space (about 2 mb), the charger will write charge tracking data to the drive.  The 

Fault / Error / USB Indicator will flash green during reading and writing.  

3.  If the drive contains compatible configuration files, the charger will load them.

4.  The IC650 Charger will briefly reset.

5.  Remove the drive when the Fault / Error / USB indicator is solid green.

Figure 4.Insert the USB flash drive to begin the reprogramming process. 

When complete, the Fault / Error / USB indicator will be solid green as shown.

Содержание IC650

Страница 1: ...650W Industrial Battery Charger Delta Q Technologies Corp 3755 Willingdon Avenue Burnaby BC V5G 3H3 CANADA Web www delta q com Phone 1 604 337 1110 E mail support delta q com 2015 Delta Q Technologies...

Страница 2: ...Delta Q IC650 Troubleshooting Guide Table of Contents 1 0 Charger Interface 4 2 0 IC650 Configuration 6 3 0 Charger Fault Codes 8 4 0 Charger Error Codes 9...

Страница 3: ...e Charge Profile Error Display shows one of four possible codes to indicate different conditions F codes mean that an internal fault condition has caused charging to stop E codes mean that an external...

Страница 4: ...5 1 1 Normal Operation Bulk charging 80 complete 1 2 Absorption Finish phase 80 complete 1 3 Charging complete...

Страница 5: ...ile is displayed press and hold the Select Charge Profile button for 10 seconds to confirm selection and exit Profile Selection Mode When the charge profile is confirmed the Error Indicator and Batter...

Страница 6: ...port from the AC connection DC disconnected or from the DC connection AC disconnected 2 If there is enough disk space about 2 mb the charger will write charge tracking data to the drive The Fault Erro...

Страница 7: ...analysis F 0 0 1 PFC failure PFC Excessive Leakage Fault Internal charger fault Remove AC and battery for minimum 30 seconds and retry charger If fault persists contact the manufacturer of your vehic...

Страница 8: ...s Replace battery pack Check DC connections Charger output reduced due to high temperatures This error will automatically clear once the charger is reset by cycling DC E 0 0 4 Battery defective Batter...

Страница 9: ...external controller over the CANbus network contact OEM for instruction E 0 1 6 E 0 1 8 E 0 1 9 E 0 2 6 Software error The software update failed Ensure the USB Flash Drive is properly formatted and...