INSTRUMENT STORAGE 

Instrument storage conditions: 

 

Temperature: -25...+55 °C. 

 

Humidity: less than 90 %RH no condensation. 

 

In storage, avoid places where: 

 

humidity is high; 

 

the instrument is exposed to direct sun radiation; 

 

the instrument is exposed to a high temperature source; 

 

high vibration levels are present; 

 

the instrument may be exposed to vapor, salt and/or corrosive gas. 

The housing of the instrument is in ABS plastic material: do not use solvents not com-
patible for cleaning. 

8

 

SAFETY INSTRUCTIONS 

General safety instructions

 

The instrument has been manufactured and tested in accordance with the safety 
standard EN61010-1:2010 “Safety requirements for electrical equipment for mea-

surement, control and laboratory use” and has left the factory in perfect safety tech-
nical conditions. 
The instrument proper operation and operating safety can be ensured only if all stan-

dard safety measures as well as the specific measures described in this manual are 
followed.  
The instrument proper operation and operating safety can be ensured only in the cli-

matic conditions specified in this manual.  
Do not use the instruments in places where there are: 

 

Rapid ambient temperature variations that may cause condensation. 

 

Corrosive or flammable gases. 

 

Direct vibrations or shocks to the instrument. 

 

High-intensity electromagnetic fields, static electricity.  

If the instrument is moved from a cold environment to a hot one or vice versa, the 

formation of condensation might cause problems to its operation. In this case you 
need to wait for the instrument temperature to reach ambient temperature before op-
eration. 

User obligations 

The instrument operator shall follow the directives and regulations below that refer to 
the treatment of dangerous materials:  

 

EEC directives on workplace safety. 

 

National law regulations on workplace safety. 

 

Accident prevention regulations. 

 

Содержание HD2024

Страница 1: ...Operating manual Acoustic calibrator HD2024 www deltaohm com English Keep for future reference Companies Brands of GHM...

Страница 2: ...5 3 1 CORRECTION DEPENDING ON THE TYPE OF MICROPHONE 5 4 BATTERY 6 4 1 LOW BATTERY INDICATION 6 4 2 BATTERY REPLACEMENT 6 4 3 CAUTIONS ON USING THE BATTERY 6 5 CONSTRUCTION AND FUNCTIONING 7 6 TECHNI...

Страница 3: ...94 4 Measurement microphones Part 4 Specifications for working standard microphones The generated sound pressure level is equal to 94 dB at 1000 Hz frequency A LED signals the low battery condition Ad...

Страница 4: ...RIPTION 1 ON OFF key turns on and off the instrument 2 LED indicating the calibrator status 3 Calibrator cavity for 1 2 microphones 4 LOW BATT LED indicates that the battery is low and needs to be rep...

Страница 5: ...with IEC 61094 1 and IEC 61094 4 standards 3 1 CORRECTION DEPENDING ON THE TYPE OF MICROPHONE The calibrator generates a 94 dB sound pressure level referred to 20 Pa Working standard 1 2 microphones...

Страница 6: ...operation of the instrument the LOW BATT LED lights up 4 2 BATTERY REPLACEMENT To replace the 9 V battery Switch off the instrument Open the lid at the bottom of the instrument Replace the battery Cl...

Страница 7: ...overpressure due to their insertion The electronics consist mainly of an oscillator combining high stability and low distor tion as well as an RMS converter the automatic gain control AGC the driver f...

Страница 8: ...e Stabilization time 10 s Total distortion 1 Ambient condition influence Temperature and humidity influence Static pressure influence 0 3 dB in the range 10 50 C and 10 90 RH 0 1 dB in the range 65 10...

Страница 9: ...operating safety can be ensured only if all stan dard safety measures as well as the specific measures described in this manual are followed The instrument proper operation and operating safety can be...

Страница 10: ...struction manual HD2020MA Microphone adapter for 1 4 capsules DELTA OHM metrology laboratories LAT N 124 are ISO IEC 17025 accredited by ACCREDIA for Temperature Humidity Pressure Photometry Radiometr...

Страница 11: ......

Страница 12: ...zed third parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic...

Страница 13: ...e result of the constant development of the product This may produce some differences between the information written in this manual and the instrument you have purchased We cannot completely exclude...

Страница 14: ...GHM GROUP Delta OHM Delta Ohm S r l a socio unico Via Marconi 5 35030 Caselle di Selvazzano Padova ITALY Phone 39 049 8977150 Fax 39 049 635596 www deltaohm com info deltaohm com V1 0 04 06 2018...

Отзывы: