![Delta Elektronika ES 030-10 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/delta-elektronika/es-030-10/es-030-10_manual_2478108005.webp)
GENERAL
ES300
5 / 13
DELTA ELEKTRONIKA B.V.
rev. Sept. 2019
2.11 MONITORING OUTPUTS
The monitor outputs give a voltage 0 - 5 V proportional to the
output current or voltage. The output current can easily be
measured without an external shunt using the CC monitor
(see fig. 2 - 6).
The monitor outputs are buffered by op-amp’s and protected
by zeners in parallel (see fig. 2 - 7). The table below shows
the impedance of the monitoring outputs. The monitoring and
the reference outputs are stable for capacitive loads up to
2 µF, for larger values a 22 Ohm resistor should be put in
series.
Note: in case of a pulsating load, the I monitor voltage will not
exactly match the output current. This is mainly caused by the
current through the output capacitors. Remote sensing will
worsen this effect.
Output
pin
Ro
Io max
Vref
9
15 Ohm
4 mA
Vmon
10
1 Ohm
4 mA
Imon
2
1 Ohm
4 mA
+12V
7
500 Ohm
25 mA
0
1
1.2 Ohm
2.12 +12V ON PROGRAMMING CONNECTOR
The +12V on the programming connector can be used for
supplying external circuits like the MASTER / SLAVE
ADAPTER. The output is current limited, but should not be
overloaded.
2.13 CC STATUS OUTPUT
The CC status output has an open output voltage of 5 V and a
short circuit current of 10 mA. This makes it possible to drive
directly: an opto-coupler, a TTL gate or a CMOS gate.
2.14 REMOTE SHUTDOWN
A voltage of +5V on the Remote ShutDown input on the
programming connector will switch off the power circuit of the
unit. In standby mode the unit consumes little power.
It is also possible to use a relay contact or a switch to shut
down the unit: connect a switch between Vref and Remote
Shutdown (pin 9 and 5).
2.15 PROGRAMMING RESPONSE TIME
The response time is measured with a step wave form at the
CV prog. input. The load is resistive. Programming from a low
to a high output voltage is nearly load independent, but
programming down to a low voltage takes more time on
lighter loads. This is caused by the output capacitors, which
can only be discharged by the load because the power supply
cannot sink current.
description
pin
description
1
0, return of reference, prog. inputs
and monitor outputs.
9
Reference voltage 5.16V
2
current monitor output (0-5V)
10
Voltage monitor output (0-5V)
3
current programming input (0-5V)
11
Voltage programming input (0-5V)
4
CC status output, logic 1 = CC
mode (5V / 4mA)
12
NC
5
Remote Shuntdown (+5V / 1mA)
13
NC
6
NC
14
NC
7
+12V output (Ri=500 Ohm)
15
NC
8
0, return of status outputs, +12V
and Remote Shuntdown.
fig 2-8 Connections analog programming connector
0Vprog.
– DC power
Warning!
0Vprog. and Minus DC power
are internally connected.