Chapter 4 Parameter Settings
|
DD Series
4-65
08 Multi-step Speed Parameter
This parameter can be set during operation.
Zero Step Speed Frequency
1
st
Step Speed Frequency
2
nd
Step Speed Frequency
3
rd
Step Speed Frequency
4
th
Step Speed Frequency
5
th
Step Speed Frequency
6
th
Step Speed Frequency
7
th
Step Speed Frequency
8
th
Step Speed Frequency
9
th
Step Speed Frequency
10
th
Step Speed Frequency
11
th
Step Speed Frequency
12
th
Step Speed Frequency
13
th
Step Speed Frequency
14
th
Step Speed Frequency
15
th
Step Speed Frequency
Control mode
VF
VFPG
SVC
FOCPG
FOCPM
Factory setting: 0.00
Settings 0.00~120.00Hz
The Multi-Function Input Terminals (refer to Pr.02-01 to 02-05) are used to select one of the AC motor
drive Multi-step speeds. The speeds (frequencies) are determined by Pr.08-00 to 08-15 as shown above.