Chapter 1 Specifications and Wiring
|
PCI-DMC-A01 / PCI-DMC-B01
1.2 Hardware
Specifications
Motion Control
Supported Module: Delta ASDA -A2-F Drive
Homing mode: 35 types (controlled using DMCNET parameter settings)
Motion Velocity Curve Control: T-curve, S-curve
Interpolation Mode: Linear, Arc, Spiral, and Continuous
DMCNET
Ring Number: 1
Serial Control Interface: half duplex RS-485 with transformer isolation
Cabling Type: CAT-5e STP Ethernet cable (24AWG/4Pairs)
Communications Distance: Up to 30 meters (12 slave modules)
General
Motion Card Dimensions (incl.Bracket): 189mm x 126mm x 20mm (Length x Width x
Height)
PCI Specifications: ver.2.2; Supports 32-bit, 3.3V/5VDC operating mode
Power Consumption: +5V DC at 0.5A typical
Surge Voltage Tolerance: 1500VAC (Primary-secondary) ¡F1500VAC (Primary-PE)
ESD: 8KV Air Discharge
EFT: Power Line-2KV
RS: 80MHz ~ 1GHz, 10V/m
Operating Temperature: 0
o
C ~ 50
o
C
1.3 Electrical Safety Precautions
To prevent electrocution, please disconnect the system from the power supply before
moving the system.
Make sure that all power supply cables have been disconnected before connecting or
disconnecting any signal wires from main card.
Please make sure that the voltage of the power supply has been set to the standard
voltage used in your current country/region. If you are unsure what the voltage of your
local power supply is, please contact your local electrical company.
If the power supply is damaged, do not attempt to repair it yourself. Please contact a
professional technician or your distributor for assistance.
1-2
Revised May, 2012