- 7 -
KAD 340
4.2 p
rogr a mmIng
the
modul ator
module
If a mono audio signal (white Cinch socket) is fed in, you program the cor-
responding channel strip of the connected mono modulator module to “
Mono
L
” (assembly instructions KMM 341 / KMS 342).
Bx 3A
Mono L
AUDIO
M
M
/
Mono L / L + R
5
f
Inal
procedures
After installing the basis unit, upgrading accessories or installing modules it is
necessary to tighten all cable connections, cable terminals and cover screws in
order to maintain compliance with current EMC regulations.
• Securely tighten the cable connections using an appropriate open-ended
spanner.
• Test the output level of the output collector according to the KAB 3000 as-
sembly instructions and set the output level required for the cable system.
• Mount the base plate and the front cover (see KAB 3000 assembly instruc-
tions).