Chapter 12 Troubleshooting
11
11.5.5.2
APF_RotaryCut_In
FB/FC
Explanation
Applicable model
FB
APF_RotaryCut_In is used for establishing the rotary-cut relationship
and specifying the axis No. of the rotary-cut axis and feed axis
according to the application requirement.
DVP15MC11T
Input Parameters
Parameter name
Function
Data type
Valid range
(Default)
Validation
timing
Execute
The instruction is
executed when
Execute
changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
(FALSE)
RotaryAxis
The axis No. of the
rotary-cut axis
USINT
1~32
(The variable
value must be set)
When
Execute
changes from
FALSE to TRUE
FeedAxis
The axis No. of the feed
axis. We suggest that the
feed axis number should
be less than the rotary cut
axis number so that the
rotary cut axis could
better follow the feed axis
for motion. The axis
number can be set in
order of 1~32 from small
to large.
USINT
1~32
(The variable
value must be set)
When
Execute
changes from
FALSE to TRUE
RotaryCutID
The number for a group of
rotary cut instructions; a
group of rotary cut
instructions use the same
number. Setting range:
1~8.
USINT
1~8
(The variable
value must be set)
When Execute
changes from
FALSE to TRUE
Output Parameters
Parameter
name
Function
Data type
Valid range
Done
TRUE when the instruction is completed.
BOOL
TRUE / FALSE
Busy
TRUE when the instruction is being executed.
BOOL
TRUE / FALSE
Error
TRUE when there is an error.
BOOL
TRUE / FALSE
ErrorID
Contains error codes when an error occurs. Please refer
to section 12.2 for the corresponding error code.
WORD
E xec ute
Rota ry Ax is
Done
Busy
Error
E rrorID
FeedAx is
Rot ary CutID
APF_RotaryCut _In
APF_Rotary Cut _In_ins tanc e
11-185
Содержание DVP15MC11T
Страница 9: ...Memo viii...
Страница 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Страница 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Страница 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Страница 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Страница 213: ...DVP15MC11T Operation Manual _8 The program 1 LIMIT EN ENO MN Out MX In LIMIT_EN LIMIT_MN LIMIT_MX LIMIT_In Out1 8 142...
Страница 216: ...Chapter 8 Logic Instructions 8_ The program 1 BAND EN ENO MN Out MX In BAND_EN BAND_MN BAND_MX BAND_In Out1 8 145...
Страница 249: ...DVP15MC11T Operation Manual _8 8 178...
Страница 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Страница 286: ...9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2 9 1...
Страница 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Страница 549: ...DVP15MC11T Operation Manual A MEMO A 16...
Страница 571: ...DVP15MC11T Operation Manual C Memo C 10...
Страница 572: ...D Appendix D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2 D 1...