12
Figure 4:
Sequential Power up
Figure 5:
Sequential Power down
Ratio-Metric Implementation
Ratio–metric is implemented by the selection of the resistor values of the voltage divider on
the TRACK pin. Resistors R1 and R2, in Figure 6 determine the tracking method that is
implemented.
To simplify the tracking design, set initial value of R2 equal to 20K
Ω
at internal circuit and set
resistor R1 for different tracking method. Figure 6 shows the circuit diagram of Ratio-Metric
start-up when Vo
PS2
tracks the Vo
PS1
.
R1
R2
TRACK
Vo
PS1
PS2
Vo
PS2
PS1
Vin
Vin
ENABLE
ENABLE
To Tracking
circuit
20K
Figure 6. PS1 and PS2 track output voltage Ratio-Metric start-up
PS1
PS2
PS1
PS2