Main Circuit Terminal Wiring
¾
Please perform the wiring after the terminal blocks are all removed from the drive.
¾
Insert only one wire into one terminal on the terminal block.
¾
When inserting wires, please ensure that the conductors are not shorted to adjacent terminals or
wires.
¾
Ensure to double check the wiring before applying power to the drive.
¾
If the wiring is in error, perform the wiring again with proper tools. Never use force to remove the
terminals or wires. Otherwise, it may result in malfunction or damage.
Installation and Storage Conditions
The product should be kept in the shipping carton before installation. In order to retain the warranty coverage,
the AC drive should be stored properly when it is not to be used for an extended period of time. Some storage
suggestions are:
Store in a clean and dry location free from direct sunlight.
Store within an ambient temperature range of -20
°
C to +65
°
C (-4
°
F to 149
°
F).
Store within a relative humidity range of 0% to 90% and non-condensing.
Do not store in a place subjected to corrosive gases and liquids.
Correctly packaged and placed on a solid surface.
Do not mount the servo drive or motor adjacent to heat-radiating elements or in direct sunlight.
Do not mount the servo drive or motor in a location subjected to corrosive gases, liquids, or airborne
dust or metallic particles.
Do not mount the servo drive or motor in a location where temperatures and humidity will exceed
specification.
Do not mount the servo drive or motor in a location where vibration and shock will exceed
specification.
Do not mount the servo drive or motor in a location where it will be subjected to high levels of
electromagnetic radiation.
Installation Note and Minimum Clearances
Installation Note:
Incorrect installation may result in a drive
malfunction or premature failure of the drive and or
motor. Please follow the guidelines in this
instruction when installing the servo drive and
motor.
The AC servo drive should be mounted
perpendicular to the wall or in the control panel.
In order to ensure the drive is well ventilated,
ensure that the all ventilation holes are not
obstructed and sufficient free space is given to the
servo drive.
Do not install the drive in a horizontal position or
malfunction and damage will occur.
Minimum Clearances:
Install a fan to increase ventilation to avoid ambient temperatures that exceed the specification. When installing
two or more drive adjacent to each other please follow the clearances as shown in the following diagram.
Содержание ASD-A0121L
Страница 1: ...5011650103 2008 05 15 03AQ...
Страница 8: ...English 7 Single Phase Power Supply Connection For 1 5kW and below models...
Страница 9: ...English 8 Basic Wiring...
Страница 10: ...English 9...
Страница 13: ...2 10 30 11 8 PG 3 9 84 PG 20 65 62 10 CHARGE...
Страница 14: ...3 20 C to 65 C 4 F to 149 F 0 90...
Страница 16: ...5 10 OFF SERVO OFF LED...
Страница 17: ...6 2kW...
Страница 18: ...7 1 5kW...
Страница 19: ...8...
Страница 20: ...9...
Страница 23: ...2 10 30 11 8 PG 3 9 84 PG 20 65 62 10 CHARGE...
Страница 24: ...3 20 C 65 C 4 F 149 F 0 90...
Страница 26: ...5 10 OFF SERVO OFF LED...
Страница 27: ...6 2kW...
Страница 28: ...7 1 5kW...
Страница 29: ...8...
Страница 30: ...9...