For remotely powered units with a maximum supply voltage of 65 VAC:
The unit may only be accessed by
trained and skilled personnel and may only be opened by them in order to switch the supply voltage on or off via
the respective plug-in fuses. The qualified personnel must follow the warnings regarding dangerous voltages.
Mounting and fixing the unit:
When mounting the device, make sure that the mounting location has sufficient
stability with regard to the weight of the device. Screws and dowels required for mounting should be sufficiently
dimensioned to hold twice the weight of the unit. Masonry or concrete is recommended as the mounting surface,
screws should have a diameter of 4-5mm.
Connection of the protective conductor according to EN 60728-11 clause 6:
Protective equipotential bonding
system must be carried out via the earthing connection point on the housing (marked with
). A protective
conductor with a cross-section of min. 2.5mm² copper (mechanically protected) or 4.0mm² copper (mechanically
unprotected) must be used. The cable shield of a subscriber cable must either be connected to the device earth or
galvanically separated. The cable shield of a connected antenna that does not have to be earthed must be
connected to the unit earth. All earth connections must be made in such a way that the connection can only be
disconnected with the aid of tools. The usual connection of a cable shield to the metal body of the socket is
sufficient for this purpose.
Caution, hot surfaces:
The housing surface can become very hot, especially at higher ambient temperatures
(from approx. 45°C), so it should not be touched directly during operation.