FEATURES 

 

RoHS compliant   

 

Compliant to SFP+ Electrical MSA SFF-8431 

 

Compliant with SFF-8472 MSA 

 

Standard LC duplex fiber-optic connector 

 

I

2

C for integrated Digital Optical Monitoring 

 

Power consumption 

1W 

 

Description 

The LCP-10G3A4EDR is a hot pluggable 
10Gbps small form factor plus transceiver 
module integrated with the high performance 
850nm VCSEL transmitter, high sensitivity PIN 
receiver and limiting amplifier for 10Gbps 
applications. It is compliant with the SFF-8431 
SFP+ Electrical Multi-source Agreement (MSA) 
with five digital monitoring functions: 
Temperature, Vcc, Tx optical power, Tx laser 
bias current and Rx received optical power. 
 
 

Applications 

 

10G LAN switch

 

 

10G Ethernet switch/router

 

 

10G Fiber channel

 

 

SAN applications

 

 

 

Содержание 10GBASE-SR SFP+ Optical Transceiver LCP-10G3A4EDR

Страница 1: ...escription The LCP 10G3A4EDR is a hot pluggable 10Gbps small form factor plus transceiver module integrated with the high performance 850nm VCSEL transmitter high sensitivity PIN receiver and limiting...

Страница 2: ...pply Voltage 3 3V VCC3 3 135 3 30 3 465 V DC Common Mode Voltage VCM 0 3 6 V Low Speed Electrical Characteristics VCC 3 135V to 3 465V Parameter Symbol Min Typ Max Unit Note Total Supply Current ICC 3...

Страница 3: ...inal 100 ppm Average Output Power Pavg 5 1 8 dBm Wavelength 840 860 nm Spectral Width RMS 0 45 nm Transmitter OFF Output Power Poff 30 dBm Extinction Ratio ER 3 Optical Modulation Amplitude OMA Compli...

Страница 4: ...al Output Amplitude 150 850 mV Stressed Receive sensitivity OMA 7 5 dBm Notes 1 Measured by reference TX with 4 75dB extinction ratio at 10 12 BER 2 When LOS asserted the data output is Low Level fixe...

Страница 5: ...0B 2008 9 5 www deltaww com Link Length Fiber type Minimum modal bandwidth 850nm MHz km Operating range meters Note 160 2 to 26 4 62 5 um MMF 200 2 to 33 4 400 2 to 66 4 500 2 to 82 4 50 um MMF 2000 2...

Страница 6: ...utput 13 CML O RD Receiver Non Inverter Data Output 14 VeeR Module Receiver Ground 1 15 VccR Module Receiver 3 3V Supply 16 VccT Module Transmitter 3 3V Supply 17 VeeT Module Transmitter Ground 1 18 C...

Страница 7: ...module RS0 is an input hardware pin which optionally selects the optical receive data path rate coverage for an SFP module RS1 is an input hardware pin which optionally selects the optical transmit pa...

Страница 8: ...TRONICS INC 8 Revision 0B 2008 9 5 www deltaww com the host board RX_LOS assert min and de assert max are defined in the relevant standard To avoid spurious transition of RX_LOS a minimum hysteresis o...

Страница 9: ...LCP 10G3A4EDR DELTA ELECTRONICS INC 9 Revision 0B 2008 9 5 www deltaww com Recommend Circuit Schematic...

Страница 10: ...DR DELTA ELECTRONICS INC 10 Revision 0B 2008 9 5 www deltaww com Package Outline Drawing for Metal Housing with Bail de latch Latch Color Identifier Black Complies with 21 CFR 1040 10 and 1040 11 Made...

Страница 11: ...0 sec 10 RX_LOS negate delay t_los_off 100 sec 11 Notes 1 Rising edge of TX_Disable to fall of output signal below 10 of nominal 2 Falling edge of TX_Disable to rise of output signal above 90 of nomin...

Страница 12: ...ormation about the module s present operating conditions 2 wire address 1010000 X A0h 2 wire address 1010001 X A2h 0 0 55 Alarm and Warning Thresholds 56 bytes 95 Serial ID Defined by SFP MSA 96 bytes...

Страница 13: ...102 00 17 03 60 03 103 00 18 00 61 52 104 00 19 1E 62 00 105 00 20 44 D 63 CS1 Note 1 106 00 21 45 E 64 00 107 00 22 4C L 65 1A 108 00 23 54 T 66 00 109 00 24 41 A 67 00 110 00 25 20 68 SN Note 2 111...

Страница 14: ...8 29 2 TX Power High Warning P 2dB 30 31 2 TX Power Low Warning P 2dB dBm 3 32 33 2 RX Power High Alarm 0dBm 34 35 2 RX Power Low Alarm 13 1dBm 36 37 2 RX Power High Warning 1dBm 38 39 2 RX Power Low...

Страница 15: ...when Tx output power is below low alarm level 113 7 Rx Power High Alarm Set when received power exceeds high alarm level 113 6 Rx Power Low Alarm Set when received power is below low alarm level 113...

Страница 16: ...act Discharge IEC EN 61000 4 2 Electrostatic Discharge ESD to the Duplex LC Receptacle Air Discharge IEC EN 61000 4 2 Human Body Model HBM MIL STD 883E Method 3015 7 EIA JESD22 A114 Electrostatic Disc...