Digital Diagnostic Monitoring Interface
Alarm and Warning Thresholds (2-Wire Address A2h)
Address
#
Bytes
Name
Value (Dec.)
Unit
Note
00-01 2
Temp
High
Alarm
85 degree Celsius
02-03 2
Temp
Low
Alarm
-10 degree Celsius
04-05
2
Temp High Warning
80 degree Celsius
06-07
2
Temp Low Warning
-5 degree Celsius
℃
1
08-09
2
Voltage High Alarm
3.6V
10-11
2
Voltage Low Alarm
3.0V
12-13
2
Voltage High Warning
3.5V
14-15
2
Voltage Low Warning
3.1V
Volt
16-17 2
Bias
High
Alarm
Iop+10 mA
18-19 2
Bias
Low
Alarm
Iop-5 mA
20-21
2
Bias High Warning
Iop+7 mA
22-23
2
Bias Low Warning
Iop-3 mA
mA 2
24-25
2
TX Power High Alarm
P +3dB
26-27
2
TX Power Low Alarm
P-3dB
28-29
2
TX Power High Warning
P +2dB
30-31
2
TX Power Low Warning
P-2dB
dBm
3
32-33
2
RX Power High Alarm
0dBm
34-35
2
RX Power Low Alarm
-13.1dBm
36-37
2
RX Power High Warning
-1dBm
38-39
2
RX Power Low Warning
-11.1dBm
dBm 4
40-45
16
Reversed
56-91
36
External Calibration Constants
92-94
3
Reversed
95
1
Checksum
5
96-97
2
Real Time Temperature
98-99
2
Real Time Supply Voltage
100-101
2
Real Time Tx Bias Current
102-103
2
Real Time Tx Optical Power
104-105
2
Real Time Rx Received Power
106-109
4
Reserved
110
1
Optional Status/ Control Bits
111
1
Reserved
112-119
8
Optional Set of Alarm and Warning
Notes:
1) T
C
: Case Operating temperature
2) I
OP
: Operating current at room temperature. The min. setting current is 0 mA.
3) P: Operating optical power of transmitter at room temperature.
4) P
0
: Overload optical power of receiver
P
S
: Sensitivity optical power of receiver
5) Byte 95 contains the low order 8bits of sum of bytes 0-94