background image

EN

10

11

2/  Connection

3/  Stop settings

3.1  Stop settings

You can use Auto mode if there are both upper and lower physical stops. The motor 
will automatically detect its end of travel distances.
If there are no upper physical stops and/or automatic locks, you must set the end of 
travel manually.  
You can use the step by step mode to stop the shutter in the exact position you 
choose.

There are several ways to configure stops:

 

• 2 automatic stops,

 

• 1 manual stop and 1 automatic stop,

 

• 2 manual stops.

• There is no priority direction for the stop teaching process. 

The recording of the first stop, whether high or low, will be confirmed by a single 

movement of the motor, and the second by 2 movements.
• Match the direction of the inverter with the direction of the shutter by 
changing the inverter wires (reverse the black wire and the brown wire).
• 

IMPORTANT: 

This operation must be done before saving the first stop.

The electrical wiring must comply with EN, IEC and national institute standards for 
installation (e.g.: NF C15-100 for France).  
In all cases, it must still be possible to switch off the power supply by using an 
omnipolar device in accordance with the applicable installation requirement. If 
the motor is delivered with a H05VVF power cable,  this cable cannot be placed 
outdoors, unless it is inside a UV-resistant duct.
For an outdoor use, the motor must be equipped with a RNF or RRF rubber cable 
with at least 2% carbon. Contact the sales department.

Connection a with fixed or temporary  

position reversing mechanism

- A change-over switch prohibiting the buttons  

 

or

 

 from being pressed 

simultaneously must be used.

- In the case where a change-over switch with temporary positions is used, the 
user must press and hold the button throughout the shutter operating time.

-  You can wire up to 3 motors on the same change-over switch for grouped controls, 
but motor stops must be adjusted separately.

3 x 0.75 mm

2

2 x 1.5 mm

2

L

L

N

N

Blue

Common (Neutral)

Brown

Phase for rotation    or  .

Black

Phase for rotation    or  .

L

Phase

N

Neutral

Black

Brown

Brown

Blue

Blue

Note: If the raise and lower 
directions are reversed, swap the 
brown and black wires (

 

and

   

 on 

the change-over switch).

230 V, 50 Hz 
single-phase 
power supply

You can connect Tyxia 5630/5730 nanomodules to Tymoov hard-wired motors 
(Tyxia 5630 recommended).
Make sure they are compatible by checking that the manufacturing date code is 
greater than or equal to the following one:
Tyxia 5630: 19d10
Tyxia 5730: 19h10
the shutter travel time must also be adjusted after setting the motor stops. To do 
this, download the Tyxia 5630/5730 manual and follow the ‘Manual adjustment 
for the shutter travel time’ procedure in the ‘Additional information’ section.

Содержание TYMOOV 10F2

Страница 1: ...EN Tubular Motor range TYMOOV 6F2 10F2 20F2...

Страница 2: ...nd that the risks involved have been understood Children must not play with the device Cleaning and maintenance by the user must not be carried out by unsupervised children The operating device of an...

Страница 3: ...dicates the nominal torque and operating time TYMOOV xF2 tubular motors are designed to operate intermittently 4 minutes of continuous operation They are electronically protected to prevent overheatin...

Страница 4: ...s 12 3 3 Setting 1 manual stop 1 automatic stop 13 3 4 Setting 2 manual stops 14 4 Clearing stops 15 4 1 By wiring 15 4 2 By the inverter 2 options 15 5 Troubleshooting 16 Power supply 230V 50 Hz 10 C...

Страница 5: ...L Total length TYMOOV 6Nm 10 Nm and 20 Nm 395 mm 422 mm Tube L length for drilling wheel attachment by screws or rivet 1 3 Motor head position The motor head must be positioned on the mount such that...

Страница 6: ...s cable cannot be placed outdoors unless it is inside a UV resistant duct For an outdoor use the motor must be equipped with a RNF or RRF rubber cable with at least 2 carbon Contact the sales departme...

Страница 7: ...ade Press and hold the button briefly until the shutter reaches the upper stop The stop position will now be automatically set The motor will be activated once Press and hold the button until the shut...

Страница 8: ...to the system again The stops have now been cleared You can store them over again 4 2 By the inverter 2 options 4 2 1 From the lower position Lower the shutter completely Press O STOP within 5 seconds...

Страница 9: ...nd of travel points are not applied Check the mechanical components of the system stabilisation play distortion etc Check whether there is a fault linked to the end of travel settings and reset them R...

Страница 10: ...www deltadore com 12 20...