10
11
2/ Connection
3/ Stop settings
3.1 Stop settings
You can use Auto mode if there are both upper and lower physical stops. The motor
will automatically detect its end of travel distances.
If there are no upper physical stops and/or automatic locks, you must set the end of
travel manually.
You can use the step by step mode to stop the shutter in the exact position you
choose.
There are several ways to configure stops:
• 2 automatic stops,
• 1 manual stop and 1 automatic stop,
• 2 manual stops.
• There is no priority direction for the stop teaching process.
The recording of the first stop, whether high or low, will be confirmed by a single
movement of the motor, and the second by 2 movements.
• Match the direction of the inverter with the direction of the shutter by
changing the inverter wires (reverse the black wire and the brown wire).
•
IMPORTANT:
This operation must be done before saving the first stop.
The electrical wiring must comply with EN, IEC and national institute standards for
installation (e.g.: NF C15-100 for France).
In all cases, it must still be possible to switch off the power supply by using an
omnipolar device in accordance with the applicable installation requirement. If
the motor is delivered with a H05VVF power cable, this cable cannot be placed
outdoors, unless it is inside a UV-resistant duct.
For an outdoor use, the motor must be equipped with a RNF or RRF rubber cable
with at least 2% carbon. Contact the sales department.
Connection a with fixed or temporary
position reversing mechanism
- A change-over switch prohibiting the buttons
or
from being pressed
simultaneously must be used.
- In the case where a change-over switch with temporary positions is used, the
user must press and hold the button throughout the shutter operating time.
- You can wire up to 3 motors on the same change-over switch for grouped controls,
but motor stops must be adjusted separately.
3 x 0.75 mm
2
2 x 1.5 mm
2
L
L
N
N
Blue
Common (Neutral)
Brown
Phase for rotation or .
Black
Phase for rotation or .
L
Phase
N
Neutral
Black
Brown
Brown
Blue
Blue
Note: If the raise and lower
directions are reversed, swap the
brown and black wires (
and
on
the change-over switch).
230 V, 50 Hz
single-phase
power supply
You can connect Tyxia 5630/5730 nanomodules to Tymoov hard-wired motors
(Tyxia 5630 recommended).
Make sure they are compatible by checking that the manufacturing date code is
greater than or equal to the following one:
Tyxia 5630: 19d10
Tyxia 5730: 19h10
the shutter travel time must also be adjusted after setting the motor stops. To do
this, download the Tyxia 5630/5730 manual and follow the ‘Manual adjustment
for the shutter travel time’ procedure in the ‘Additional information’ section.