Product Description 

The DFM-1616 Field Module provides additional I/O (16 
universal inputs and 16 universal outputs) to Delta’s DSC-
1616E or ASM-24E BACnet Controllers.  It communicates on 
Delta’s LINKnet network. 

The DSC-1616E when combined with two DFM-1616 Field 
Modules forms a high-density I/O Controller intended to fit a 
range of Central Plant-type applications requiring up to 48 
Inputs and 48 Outputs.  When the DFM-1616 is combined with 
the ASM-24E it forms a controller suited for Elevator Control 
applications. 

 

Important Information  

 

 

The DFM-1616 works only with the DSC-1616E and ASM-24E (firmware V3.33 R1 or later). 

Package Contents 

 

Product: DFM-1616 (Rev. 2.0a) 

 

DFM-1616 (Rev.2.0a) Installation Guide 

Related Documents 

 

Delta Controls Wiring Guidelines 

 

ORCAview Operator Guide 

 

ORCAview Technical Reference Manual  

 

Release Notes for related Firmware 

 

 

Document Edition 2.4 

Содержание DFM-1616

Страница 1: ...intended to fit a range of Central Plant type applications requiring up to 48 Inputs and 48 Outputs When the DFM 1616 is combined with the ASM 24E it forms a controller suited for Elevator Control ap...

Страница 2: ...ry with type CR2032 Equipment damage or loss of data may occur if these procedures are not followed as specified Installations requiring CE conformance All wiring for CE rated products must use an ext...

Страница 3: ...Document Edition 2 4 Board Layout Page 3 of 10...

Страница 4: ...set the address simply move the switches that add up to the controllers desired address to the ON position Example If the controller is to be address 5 on the network set the switch numbered 4 and th...

Страница 5: ...sformer may be used to power multiple controllers and or auxiliary field devices actuators etc provided the following conditions are met All devices MUST be wave rectified Mixing power between wave an...

Страница 6: ...hen 100 ft of cable length do not require network terminators LINKnet Controller Outputs with Communication Failure When using this controller special consideration must be given to the fail value of...

Страница 7: ...turns on to indicate that the controller has power applied Scan CPU Scan Indicator This red LED flashes at a rate relative to the CPU scan rate Network NET1 LINKnet RS485 Communication Status Indicato...

Страница 8: ...puts 16 Universal Inputs 10 bit jumper configurable for the following input types 0 5 VDC 0 10 VDC 10 K Thermistor Dry Contact using 10 K Thermistor jumper setting 4 20 mA Outputs 16 Universal Outputs...

Страница 9: ...999 Power Line Harmonics Class A EN 61000 3 3 1998 Power Line Fluctuations Pst 1 Plt 0 65 EN 50082 1 1997 Generic Immunity Standard Part 1 Residential EN 61000 4 2 1995 ESD Immunity Level B EN 61000 4...

Страница 10: ...accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case t...

Отзывы: