DL-00035 Rev. 4

iii

The ringer equivalence number (REN) is used to determine the number of devices 

that may be connected to a telephone line. Excessive RENs on a telephone line 

may result in the devices not ringing in response to an incoming call. In most, but 

not all, areas the sum of RENs should not exceed five (5). To be certain of the 

number of devices that may be connected to a line, as determined by the total RENs, 

contact the local telephone company. For products approved after July 23, 2002, 

the REN is part of the product identifier that has the format US:AAAEQ##TXXXX. 

The digits represented by ## are the REN without a decimal point (i.e., 03 is a REN 

of 0.3). For earlier products, the REN is separately shown on the label.

If this VitalPoint Home Monitor causes harm to the telephone network, the  

telephone company will notify you in advance that temporary discontinuance of 

service may be required. But if advance notice isn’t practical, the telephone compa-

ny will notify the customer as soon as possible. Also, you will be advised of your 

right to file a complaint with the FCC if you believe it’s necessary.

The telephone company may make changes in its facilities, equipment, operations, 

or procedures that could affect the operation of the VitalPoint Home Monitor. If this 

happens, the telephone company will provide advance notice in order for you to 

make necessary modifications to maintain uninterrupted service.

Connection to party line service is subject to state tariffs (U.S.). Contact the state  

public utility commission, public service commission, or corporation commission 

for information.

If installed in a home with specially wired alarm equipment connected to the  

telephone line, ensure the installation of the VitalPoint Home Monitor does not  

disable the alarm equipment. If you have questions about what will disable alarm 

equipment, consult the telephone company or qualified installer.

Electrical safety advisory: Parties responsible for equipment requiring AC power 

should consider including an advisory notice in their customer information suggest-

ing the customer use a surge arrestor. Telephone companies report that electrical 

surges, typically lightning transients, are very destructive to customer terminal 

equipment connected to AC power sources. This has been identified as a major 

nationwide problem.

Содержание VitalPoint Home Monitor

Страница 1: ...Delphi Medical Systems VitalPoint Home Monitor Patient Guide...

Страница 2: ...lphi Medical Systems Remote Device Connectivity complies with the U S Health Insurance Portability and Accountability Act HIPAA protecting the security and privacy of health data It is recommended tha...

Страница 3: ...laint with the FCC if you believe it s necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the VitalPoint Home Moni...

Страница 4: ...iv DL 00035 Rev 4 This equipment is ETL listed This equipment is classified as Class II Type CF IPX0 Continuous operation Classification...

Страница 5: ...res Serial number Catalog number U S federal law restricts this device to sale by or on the order of a physician On Off only Class II device This end up Fragile breakable Atmospheric pressure limitati...

Страница 6: ...r a checkup or requiring the clinician to go to the patients It provides periodic remote monitoring of the patients self reported symptoms or vital signs including Non invasive blood pressure Oxygen s...

Страница 7: ...Home Monitor is set up for a specific patient s needs by a clinician While the VitalPoint Home Monitor is intended for use in adult and pediat ric patients the user interface is tailored for an adult...

Страница 8: ...NVENTIONS IN THIS USER MANUAL This guide contains warnings precautions and notes to help call your atten tion to the most important safety and operational aspects of the system To help identify these...

Страница 9: ...H AS SINKS SHOWERS OR BATHTUBS 4 UNPLUG THE MONITOR BEFORE CLEANING DO NOT SPRAY CLEANERS INTO THE RECEPTACLES 5 DO NOT USE A MONITOR OR ANY ACCESSORY THAT SHOWS ANY SIGN OF DAMAGE 6 DO NOT USE THE MO...

Страница 10: ...ATIENTS MOVE THE SENSOR IF YOU SEE ANY SIGNS OF SKIN IRRITATION OR IMPAIRED CIRCULATION ELEVATED LEVELS OF CARBOXYHEMOGLOBIN OR METHEMOGLOBIN IN MONITORED PATIENTS CAN RESULT IN INACCURATE PULSE OXIME...

Страница 11: ...NT HOME MONITOR 7 THE VITALPOINT HOME MONITOR SHOULD NOT BE USED ADJACENT TO OR STACKED WITH OTHER EQUIPMENT AND THAT IF ADJACENT OR STACKED USE IS NECESSARY THE VITALPOINT HOME MONITOR SHOULD BE OBSE...

Страница 12: ...LEMS WITH THE PULSE OXIMETRY MEASUREMENTS RESULTING IN INACCURATE PULSE OXIMETRY READINGS IF THE SENSOR IS IN A PLACE WHERE IT MAY BE EXPOSED TO BRIGHT LIGHT COVER THE SENSOR WITH SOME OPAQUE MATERIAL...

Страница 13: ...IRES AWAY FROM SOURCES OF LINE NOISE TO AVOID LARGE OFFSET POTENTIALS DUE TO POLARIZATION OF ELECTRODES BE SURE TO USE ONLY ELECTRODE TYPES SPECIFIED FOR THIS DEVICE AND BE SURE THAT ALL ELECTRODES US...

Страница 14: ...mming Feature 4 Power Supply 4 Phone Connection 5 Monitor Setup 5 Important Reminders 6 For Help 7 Operating the VitalPoint Home Monitor 8 Selecting Options 8 Main Menu Screen 9 Reporting Symptoms 11...

Страница 15: ...ed to devices such as a digital weight scale prothrombin time meter fluid status monitor and a blood glucose meter Your clinician can also use the monitor to send you messages reminding you to conduct...

Страница 16: ...for qualified ser vice personnel only Battery charging indica tor LED power connected and battery charging when lit Serial number Catalog number Power on indicator LED on when lit Fluid status monito...

Страница 17: ...cle NBP Temperature probe receptacle TEMP Weight scale receptacle 3 Glucose meter receptacle 2 Electrocardiogram receptacle ECG Fluid status monitor receptacle 1 Power receptacle USB port for Delphi a...

Страница 18: ...powered on The monitor should be left on at all times while in your home Dimming Feature The monitor s main screen will automatically dim after 5 minutes so that the brightness will not disturb a pati...

Страница 19: ...The Monitor could not communicate with the Central Server You will be returned to the Main Menu Monitor will keep trying to dial the Central Server every five minutes Data will be stored until succes...

Страница 20: ...your data DO NOT allow anyone else to use the monitor to avoid mistakes in your medical record Discuss all medications with your physician If any of the following occurs contact your clinician immedia...

Страница 21: ...stments such as volume control if necessary If you have questions about this information or about the safe operation of the monitor or do not understand any of the instructions on the screen call your...

Страница 22: ...e button on the screen with your finger Some screens allow for only one response for example yes or no questions As soon as you select your answer the monitor moves on to the next screen IMPORTANT The...

Страница 23: ...s Continue to move on Note At any time you may press Go Back to review the previous menu screen or Main Menu to return to the Main Menu screen MAIN MENU SCREEN The Main Menu displays a personal greeti...

Страница 24: ...Report symptoms Take measurements See nurse s instructions Adjust speaker volume or dial Central Server To report symptoms press Report Symptoms and follow the instructions on the screen To take meas...

Страница 25: ...an emergency response system Press Continue to report symptoms The monitor allows you to report symptoms related to Breathing Swelling Heart Stomach bowel Urine Wound Pain General For each problem yo...

Страница 26: ...rrect press Yes send the problems to my clinician now to send the report to your clinician If the reported problems are correct but you have additional measurements to take press Yes but I would like...

Страница 27: ...o Please remain still measurement may take some time After the measurement is complete the measurement results will be displayed on the screen After each measurement you will be asked if you have more...

Страница 28: ...a table Remain still and do not talk while your blood pressure is being taken When ready press Take Measurement and remain still until the measurement is complete When finished the measurement will b...

Страница 29: ...ollow the instructions on the screen and contact your clinician Measuring Temperature The monitor will display the following instructions to use the temperature probe and take a temperature reading 1...

Страница 30: ...e If you receive any error codes while taking measurements follow the instructions on the screen and contact your clinician Measuring Prothrombin Time 1 Press Take Measurements 2 Press Protime The mon...

Страница 31: ...Place the first electrode just above the top of your breastbone with the arrow pointing down 3 Place the second electrode just below the bottom of your breastbone with the arrow pointing up 4 Press th...

Страница 32: ...rted This allows the scale to re zero itself and become prepared to take your weight Press Continue 4 Step on the platform and remain as still as possible without leaning on anything When ready press...

Страница 33: ...activity if there is one The monitor will return to the Main Menu if no additional activities are scheduled If you answer No the monitor will ask you why you did not take your medication PRECAUTION Y...

Страница 34: ...next activity if one is scheduled The monitor will return to the Main Menu if no additional activities are scheduled VIEWING NURSE S INSTRUCTIONS Nurse s instructions are available through the Main Me...

Страница 35: ...NG SETUP OPTIONS To change the speaker volume or initiate a connection with the Central Server press Setup on the Main Menu To adjust the speaker volume press Setup When the next screen is displayed p...

Страница 36: ...s highlighted in yellow of the voice prompt Press Go Back if you would like to return to the Main Menu Press Continue if you would like to adjust the alarm volume To initiate a connection with the Cen...

Страница 37: ...o not use your phone until the monitor indicates Confirmation Monitor successfully communicated with the Central Server Concluding Activities IMPORTANT If you attempt to use your phone while the monit...

Страница 38: ...The monitor will continue to try to dial the Central Server until communication is successful If communication is not successful you will receive a final message Monitor has not been able to communic...

Страница 39: ...ined and is believed to be reliable Furthermore Delphi Medical Systems reserves the right to make changes to any products herein to improve readability function or design Delphi Medical Systems does n...

Страница 40: ...POINT MONITOR DE SINAIS VITAIS Importado por Delphi Automotive Systems do Brasil Ltda CNPJ 00 857 758 0001 40 Av Goi s 1820 1860 Santa Paula S o Caetano do Sul SP Fone 55 11 4234 9500 e mail delphi de...