![Delphi DEA601 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/delphi/dea601/dea601_owners-manual_2471013039.webp)
Owner´s Manual DEA601 Radio
39 |
P a g e
Figure 77 Warning KW Oil Temp Gauge state Art Work
3.
Error States (Needle Deflection)
o
If Data is not available, the gauge pointer shall
automatically be positioned in - 15° from the Null position
and stay in that position until data is available.
o
If the gauge is under scaled, the gauge pointer
automatically be positioned in - 5° from the Null position
and stay in that position until data is rescaled.
o
If the gauge is over scaled, the gauge pointer
automatically be positioned in + 5° from the Null position
and stay in that position until data is rescaled.
Virtual Gauges Pop-Up
All the Virtual Gauges function as softkeys, each Virtual Gauge softkey
toggle to a full screen zoom of the gauge when the user presses the Virtual
Gauge softkey.
While the Virtual Gauge is toggled to full screen zoom, a press of the screen
returns the gauge to its original size.
If the user presses the screen while the Virtual gauge is in process to toggle
in a full screen zoom, Virtual Gauges app cancel the full screen zoom toggle.
Gauges are automatically toggled to full screen zoom when a Warning State
is present.
If a Virtual Gauge has been toggled to full screen due to a warning condition
and another Virtual Gauge presents a warning condition, the first Virtual
Gauge in a warning state will be displayed for at least 3 seconds. After 3
seconds, the Virtual Gauge in a full screen state due to a warning state
return to a normal state allowing the second Virtual Gauge in a warning to
state to toggle to full screen.
All the Virtual Gauges minimized after being in full screen due to a warning
state remain in the warning state in their original size while the warning
condition of the gauge persists.
Gauges Settings
Pressing the soft key or hard key the Virtual Gauges app presents a pop-
up menu with the following elements.
Figure 78
as reference.
Preset 1 - Soft key
Preset 2 - Soft key
Edit Presets
Load Updates
Factory Reset
Presets
Presets are used to define personalized views of the gauges. Two presets
are available to save different combinations of the available gauges.