27

A

IR PURIFYING/FAN MODE (FIG. 17)

When using the appliance in this mode, the air exhaust hose
does not need to be attached. 
To set this mode correctly: 

Press the 

MODE

button a number of times until the fan symbol

appears.

Select the required fan speed by pressing the 

FAN

button.

Three speeds are available:

High speed:

for maximum fan power

Medium speed: 

reduces noise levels but still main-

tains a good level of comfort

Low speed:

for silent operation

In this mode, AUTO speed cannot be selected.

H

EATING MODE

(

FIG

. 18)

To set this function correctly: 

Press the MODE button a number of times until the heating
symbol (6) appears.

Select the required temperature by pressing the + or - button
until the corresponding value is displayed. 

In heating mode, the fan speed is selected automatically by
the appliance.

Water is removed from the air and collected in the tank at the
back of the air conditioner.

When the tank is full, the appliance shuts down and "       " (full
tank) appears on the display. The tank must be extracted and
emptied (fig. 15).
When the tank has been emptied, the appliance starts up again.
The continuous drain hose accessory enables the condensate
produced to be eliminated without requiring the tank to be emp-
tied periodically.
To use the continuous drain function, fit the hose with the rapid
coupling as shown in fig. 16.

S

MART

M

ODE

(FIG. 19)

To  select this mode, press the MODE button a number of times
until the SMART symbol (7) appears.
In this mode, the appliance decides automatically whether to
operate in air conditioning, fan or heating mode, the most suita-
ble temperature for optimum well-being and the fan speed.

S

WING

B

UTTON

(15)

Moves the grille flaps to distribute the cool air uniformly in the
room.

When the 

SWING

button is pressed once, the flaps begin

moving alternately forwards and backwards. Press the SWING
button again to stop the flaps in their current position. Pressing
the button again will restart the flaps moving forwards and
backwards.

When the appliance is turned off, the flaps will close irrespec-
tive of their position.

27

17

19

When operating in very

cold rooms, the appliance
defrosts automatically,
momentarily interrupting nor-
mal operation. "

LT" 

appears

on the display. During this
operation, it is normal for the
noise made by the applian-
ce to change. 

In this mode, the fan

may operate for short
periods, even though the
set temperature has
already been reached. 

✔ 

18

Downloaded from AC-Manual.com Manuals

Содержание PAC T10HP

Страница 1: ...nce always unplug the appliance from the mains socket Never unplug the appliance by pulling on the power cable Do not install the appliance in rooms containing gas oil or sulphur Do not install near s...

Страница 2: ...overed to obtain significant savings in energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled dustbin ELECTRICAL...

Страница 3: ...ted from one building to another Hot air from the room is passed through a heat exchanger cooled by refrigerant gas Excess heat and moisture are removed before the air is re emitted into the room In s...

Страница 4: ...nnection I condensate tank J power cable K flange cap L air exhaust hose M window outlet N suckers O castor locks P continuous drain hose with coupling Q remote control R 3M air purifying filter S sil...

Страница 5: ...hose is unobstructed Open the window or French window slightly and position the outlet fig 2 If you have a double window use the sucker provided to hold the two parts of the window together fig 3 You...

Страница 6: ...sing at the back of the appliance fig 1 Fit the end of the hose to the flange as shown in fig 8 When the hose is not fitted the hole can be closed with the flange cap Keep the air hose as short and fr...

Страница 7: ...in the same mode as when turned off Never turn the air conditioner off by unplugging from the mains Always press the button then wait for a few minutes before unplugging This allows the appliance to p...

Страница 8: ...e room humidity spring and autumn damp rooms rainy periods etc Place the appliance in the room without fitting the air exhaust hose L To set this mode correctly Press the MODE button a number of times...

Страница 9: ...cessory enables the condensate produced to be eliminated without requiring the tank to be emp tied periodically To use the continuous drain function fit the hose with the rapid coupling as shown in fi...

Страница 10: ...the factory default settings 20 Timer ON button 21 SET button 22 Timer OFF button 23 SWING button 24 SLEEP button 25 C or F selection button USING THE REMOTE CONTROL Point the remote control at the re...

Страница 11: ...display flas hes until the time is set Proceed as follows Press the or button until the correct time is reached Hold the button down to run rapidly through first the minutes then the tens of minutes a...

Страница 12: ...tions During air conditioning the temperature increases by 1 C every 60 minutes and a further degree after 2 hours In dehumidifying mode the dehumidifying power of the applian ce is partially reduced...

Страница 13: ...ontrol display and the symbol is displayed on the appliance to indicate that the timer is active SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error mes...

Страница 14: ...liance AIR PURIFYING FILTERS he appliance is fitted with a silver ion dust filter which retains the impurities in the air drawn in from the room and a 3M electro static filter which retains the finest...

Страница 15: ...g it from the grille Use a vacuum cleaner to remove dust accumulations from the sil ver ion filter If it is very dirty immerse in warm water and rinse a number of times The water should never be hotte...

Страница 16: ...ter clog ged the technical specification of the appliance is not adequa te for the room in which it is located close doors windows and curtains bearing in mind the tips for correct use given above eli...

Страница 17: ...ing power LIMIT CONDITIONS Temperature of room in air conditioning 21 35 C Temperature of room in heating 10 27 C SIZE OF APPLIANCE width 495 mm height 950 mm depth 430 mm width 34 kg GUARANTEE The te...