IR CONDITIONING MODE (FIG. 13)

Ideal for hot muggy weather when you need to cool and dehu-
midify the room. 
To set this mode correctly: 

Press the 

MODE

button a number of times until the air-condi-

tioning symbol (3) appears.

Select the target temperature by pressing the 

+

or 

-

button

until the corresponding value is displayed.

Select the required fan speed by pressing the 

FAN

button.

Four speeds are available:

High speed: 

to achieve the target temperature

as rapidly as possible

Medium speed: 

reduces noise levels but still

maintains a good level of comfort

Low speed:

for silent operation

Auto speed:

the appliance automatically selects

the most suitable fan speed in relation to the tem-
perature set on the digital display.

The most suitable temperature for the room during the summer
varies from 24 to 27°C. You are recommended, however, not to
set a temperature much below the outdoor temperature.

D

EHUMIDIFYING MODE (FIG. 14)

Ideal to reduce room humidity (spring and autumn, damp rooms,
rainy periods, etc).  
Place the appliance in the room without fitting the air exhaust
hose (L).
To set this mode correctly: 

Press the 

MODE

button a number of times until the dehumidif-

ying symbol (4) appears, then press the 

+

or 

-

button until the

required humidity level is displayed. At the same time, the
Auto fan light comes on as the appliance automatically
selects the most appropriate speed. Water is removed from
the air and collected in the tank at the back of the air condi-
tioner. When the tank is full, the appliance shuts down and
(full tank) appears on the display. The tank must be extracted
and emptied (fig. 

15

). When the tank has been emptied, the

appliance starts up again. 

The accessory continuous drain hose enables the condensa-
te produced to be eliminated without requiring the tank to be
emptied periodically. Fit the hose with the rapid coupling as
shown in fig. 

16

.

NB

: In order for the continuous drain function to operate cor-

rectly, make sure the accessory is fully connected to the
coupling. To release, press the coupling flange.

26

13

14

15

16

Downloaded from AC-Manual.com Manuals

Содержание PAC T10HP

Страница 1: ...nce always unplug the appliance from the mains socket Never unplug the appliance by pulling on the power cable Do not install the appliance in rooms containing gas oil or sulphur Do not install near s...

Страница 2: ...overed to obtain significant savings in energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled dustbin ELECTRICAL...

Страница 3: ...ted from one building to another Hot air from the room is passed through a heat exchanger cooled by refrigerant gas Excess heat and moisture are removed before the air is re emitted into the room In s...

Страница 4: ...nnection I condensate tank J power cable K flange cap L air exhaust hose M window outlet N suckers O castor locks P continuous drain hose with coupling Q remote control R 3M air purifying filter S sil...

Страница 5: ...hose is unobstructed Open the window or French window slightly and position the outlet fig 2 If you have a double window use the sucker provided to hold the two parts of the window together fig 3 You...

Страница 6: ...sing at the back of the appliance fig 1 Fit the end of the hose to the flange as shown in fig 8 When the hose is not fitted the hole can be closed with the flange cap Keep the air hose as short and fr...

Страница 7: ...in the same mode as when turned off Never turn the air conditioner off by unplugging from the mains Always press the button then wait for a few minutes before unplugging This allows the appliance to p...

Страница 8: ...e room humidity spring and autumn damp rooms rainy periods etc Place the appliance in the room without fitting the air exhaust hose L To set this mode correctly Press the MODE button a number of times...

Страница 9: ...cessory enables the condensate produced to be eliminated without requiring the tank to be emp tied periodically To use the continuous drain function fit the hose with the rapid coupling as shown in fi...

Страница 10: ...the factory default settings 20 Timer ON button 21 SET button 22 Timer OFF button 23 SWING button 24 SLEEP button 25 C or F selection button USING THE REMOTE CONTROL Point the remote control at the re...

Страница 11: ...display flas hes until the time is set Proceed as follows Press the or button until the correct time is reached Hold the button down to run rapidly through first the minutes then the tens of minutes a...

Страница 12: ...tions During air conditioning the temperature increases by 1 C every 60 minutes and a further degree after 2 hours In dehumidifying mode the dehumidifying power of the applian ce is partially reduced...

Страница 13: ...ontrol display and the symbol is displayed on the appliance to indicate that the timer is active SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error mes...

Страница 14: ...liance AIR PURIFYING FILTERS he appliance is fitted with a silver ion dust filter which retains the impurities in the air drawn in from the room and a 3M electro static filter which retains the finest...

Страница 15: ...g it from the grille Use a vacuum cleaner to remove dust accumulations from the sil ver ion filter If it is very dirty immerse in warm water and rinse a number of times The water should never be hotte...

Страница 16: ...ter clog ged the technical specification of the appliance is not adequa te for the room in which it is located close doors windows and curtains bearing in mind the tips for correct use given above eli...

Страница 17: ...ing power LIMIT CONDITIONS Temperature of room in air conditioning 21 35 C Temperature of room in heating 10 27 C SIZE OF APPLIANCE width 495 mm height 950 mm depth 430 mm width 34 kg GUARANTEE The te...

Отзывы: