DèLonghi PAC T10HP Скачать руководство пользователя страница 1

19

IMPORTANT SAFEGUARDS

•  Use this appliance only as described in this instruction manual. As with all electrical equip-

ment, whilst the instructions aim to cover as many eventualities as possible, caution and
common sense should be applied when operating and installing this appliance.

•  This appliance is designed for home air conditioning and must not be used for other pur-

poses 

•  It is dangerous to modify or alter the characteristics of the appliance in any way.
•  The appliance must be installed in conformity with national legislation regulating electrical

equipment and installations.

•  If the appliance requires repair, contact a Service Centre authorised by the manufacturer

only. Repairs carried out by unauthorised personnel may be dangerous.

•  This appliance must be used exclusively by adults. 
•  Never allow the appliance to be used by people (including children) with psychological,

physical or sensory impairments or with insufficient experience and knowledge, unless clo-
sely supervised and instructed by someone responsible for their safety. Young children
should be supervised to ensure that they do not play with the appliance.

•  The appliance must be connected to an efficient earth system. Have your electrical circuit

checked by a qualified electrician.

•  Do not use extension cables. 
•  Before cleaning or maintenance, always unplug the appliance from the mains socket. 
•  Never unplug the appliance by pulling on the power cable. 
•  Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sour-

ces of heat 

•  Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pres-

surised containers (eg aerosol cans). 

•  Do not rest heavy or hot objects on top of the appliance. 
•  Clean the air filter at least once a week. 
•  Avoid using heating appliances near the air conditioner.
•  Always transport the appliance upright or resting on one side. Before moving the applian-

ce, empty the internal circuit completely of water. After moving the appliance, wait at least
1 hour before starting it.

•  When putting the appliance away, do not cover with plastic bags. 
•  The materials used for packaging can be recycled. You are therefore recommended to dis-

pose of them in special differentiated waste collection containers.

•  At the end of its working life, consign the appliance to a specialist collection centre.
•  If the power cable is damaged, it must be replaced by the manufacturer or an authorised

technical service centre in order to avoid all risk.

•  R410A refrigerant gas conforms to EC regulations on the environment. Avoid perforating the

refrigerant circuit of the appliance.

• 

ENVIRONMENTAL INFORMATION:  

This unit contains fluorinated greenhouse gases covered

by the Kyoto Protocol.  Maintenance and disposal must be carried out by qualified per-
sonnel only (R410A, GWP=1975).

GB

Downloaded from AC-Manual.com Manuals

Содержание PAC T10HP

Страница 1: ...nce always unplug the appliance from the mains socket Never unplug the appliance by pulling on the power cable Do not install the appliance in rooms containing gas oil or sulphur Do not install near s...

Страница 2: ...overed to obtain significant savings in energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled dustbin ELECTRICAL...

Страница 3: ...ted from one building to another Hot air from the room is passed through a heat exchanger cooled by refrigerant gas Excess heat and moisture are removed before the air is re emitted into the room In s...

Страница 4: ...nnection I condensate tank J power cable K flange cap L air exhaust hose M window outlet N suckers O castor locks P continuous drain hose with coupling Q remote control R 3M air purifying filter S sil...

Страница 5: ...hose is unobstructed Open the window or French window slightly and position the outlet fig 2 If you have a double window use the sucker provided to hold the two parts of the window together fig 3 You...

Страница 6: ...sing at the back of the appliance fig 1 Fit the end of the hose to the flange as shown in fig 8 When the hose is not fitted the hole can be closed with the flange cap Keep the air hose as short and fr...

Страница 7: ...in the same mode as when turned off Never turn the air conditioner off by unplugging from the mains Always press the button then wait for a few minutes before unplugging This allows the appliance to p...

Страница 8: ...e room humidity spring and autumn damp rooms rainy periods etc Place the appliance in the room without fitting the air exhaust hose L To set this mode correctly Press the MODE button a number of times...

Страница 9: ...cessory enables the condensate produced to be eliminated without requiring the tank to be emp tied periodically To use the continuous drain function fit the hose with the rapid coupling as shown in fi...

Страница 10: ...the factory default settings 20 Timer ON button 21 SET button 22 Timer OFF button 23 SWING button 24 SLEEP button 25 C or F selection button USING THE REMOTE CONTROL Point the remote control at the re...

Страница 11: ...display flas hes until the time is set Proceed as follows Press the or button until the correct time is reached Hold the button down to run rapidly through first the minutes then the tens of minutes a...

Страница 12: ...tions During air conditioning the temperature increases by 1 C every 60 minutes and a further degree after 2 hours In dehumidifying mode the dehumidifying power of the applian ce is partially reduced...

Страница 13: ...ontrol display and the symbol is displayed on the appliance to indicate that the timer is active SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error mes...

Страница 14: ...liance AIR PURIFYING FILTERS he appliance is fitted with a silver ion dust filter which retains the impurities in the air drawn in from the room and a 3M electro static filter which retains the finest...

Страница 15: ...g it from the grille Use a vacuum cleaner to remove dust accumulations from the sil ver ion filter If it is very dirty immerse in warm water and rinse a number of times The water should never be hotte...

Страница 16: ...ter clog ged the technical specification of the appliance is not adequa te for the room in which it is located close doors windows and curtains bearing in mind the tips for correct use given above eli...

Страница 17: ...ing power LIMIT CONDITIONS Temperature of room in air conditioning 21 35 C Temperature of room in heating 10 27 C SIZE OF APPLIANCE width 495 mm height 950 mm depth 430 mm width 34 kg GUARANTEE The te...

Отзывы: