![DèLonghi GSI501A Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/delonghi/gsi501a/gsi501a_user-operating-instructions-manual_2469051021.webp)
21
Table for the choice of the injectors
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION
(2 m
3
/h kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,80
Rapid burner (R)
5,90
Thermostat oven
6,50
Grill
4,70
G 30
- 28 mbar
G 20
BURNERS
G 31
- 37 mbar
20 mbar
Auxiliary (A)
1,00
0,30
27
50
3
72
1
Semi-rapid (SR)
1,90
0,38
29
67
5,7
100
2
Rapid (R)
2,95
0,60
39
83
fully open
125
3
Oven
3,25
0,65
41
86
fully open
130
5
Grill
2,35
–
–
78
fully open
–
115
5
Nominal
Power
[kW]
Reduced
Power
[kW]
Ring opening
[mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ring opening
[mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
GB
Cat:
II
2H3+
adjustable
Содержание GSI501A