Gas connection
The installation of the cooker to Natural Gas or LP Gas must be carried out by a
qualified gas engineer. Installer shall take due account of the provisions of the relevant
British Standards Code of Practice, the Gas Safety Regulations and the Building Standards
(Scotland) (Consolidation) Regulations issued by the Scottish Development Department.
Installation to LP Gas
This appliance must only be connected to LPG after an LPG conversion kit has been
fitted, (see pages from 19 to 24).
When operating on Butane gas a supply pressure of 28 mbar is required.
When using Propane gas a supply pressure of 37 mbar is required.
The installation must conform to the relevant British Standards.
Installation to Natural Gas
Installation to Natural Gas must conform to the Code of Practice, etc. The supply
pressure for Natural Gas is 20 mbar.
Warning:
Only a qualified gas engineer, also with technical knowledge of electricity
should install gas cookers. They should observe the Regulations and Codes of Practice
governing such installation of gas cookers.
Note:
It is recommended that the gas connection to the cooker is installed with
a flexible connecting tube made to BS 5386.
Plug
Gas connection
The gas supply must be connected
to the gas inlet which is located at
the left or right hand rear of the
appliance (see figure 15)
After connecting to the mains,
check that the coupling are
correctly sealed, using soapy
solution, but never a flame.