DèLonghi DEINV27 Скачать руководство пользователя страница 22

Install indoor unit 

PP

6

PP

6

PP

PP

Ø 

65

Install the rear panel 

1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the 

both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is 

taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and 

level should be 0 or more, that is good for condensing water drainage. 

2.Fix the rear panel on the wall with screws.  
(Where is pre-covered with plastic granula) 

3.Be sure that the rear panel has been fixed   
firmly enough to withstand the weight of an 
adult of 60kg, further more, the weight should 
be evenly shared by each screw.

Install the piping hole 

1.Make the piping hole (Ф55) in the wall at a slight downward slant to the  

   outdoor side.  

2.Insert the piping-hole sleeve into the hole to prevent the connection piping  
   and wiring from being damaged when passing through the hole. 

Install the water drainage pipe 

1.For well draining, the drain hose should be placed at a downward slant. 

2.Do not wrench or bend the drain hose or flood its end by water. 

3.When the long drainage hose passing through indoor,  
   should wrap the insulation materials. 

Wrenched

 

Bent

 

Flooded 

Indoor Outdoor 

Wall pipe 

Seal pad 

 

Wall 

Wall 

Mark on the middle of it 

Gradienter 

Left 

Right 

(Rear piping hole) 

(Rear piping hole) 

Space  
to the  
wall 

above 

Space  
to the  
wall 

above 

Connect indoor and outdoor electric wires 

1.Open the surface panel.
2.Remove the wiring cover 

(see figure below)

.

3.Route the power connection cord and signal control wire (for cooling and heating unit only) from the

4.Connect the interconnection cord to the terminal block, and then fix the cord with cord anchorge.

5.Reassemble the clampand wiring cover.

back of the indoor unit and pull it toward the front through the wiring hole for connection.

6.Recover the surface panel.

yellow-

green

brown

violet

yellow-

green

violet

brown

yellow-

green

 

O

N-

O

FF: 

24

K -

2

8K

 INVE

R

TE

R

 9K-

12

K-

1

8K -

22

K-

2

8K

*

 

O

N-

O

FF: 9K -

12

K

 

O

N-

O

FF: 

1

8K 

* Model Inverter 28K is supplied with an additional communication cable

Содержание DEINV27

Страница 1: ...Split Air Conditioner...

Страница 2: ...nstallation and Maintenance of Healthy Filter Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment Thank you for choosing De Longhi air con...

Страница 3: ...e the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the air conditioning capacity or cause a malfunction Keep combustible sp...

Страница 4: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Страница 5: ...ty will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low termperature there will be frost formed on the heat exchanger when indoor heat exchanger temp...

Страница 6: ...Indoor unit Air in Air out Outdoor unit Wireless remote control Remote control Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Cool Dry Fan Heat Set temp Run The pat...

Страница 7: ...tial value is 25 th otherwise is Timer value displayed on the screen that denotes and signal will be displayed If the the current time value is Clock value per 0 5second if you press again when the ti...

Страница 8: ...ff Presetting temperature can be increased Press this button the temperature can be button set up continuously press this button and hold for two seconds the relative contents can quickly change until...

Страница 9: ...ck to the current actual time Press this button to set swing angle which circularly changes as below OFF If guide louver is stopped when it is swinging up and down it will remian its present position...

Страница 10: ...he swing 1 Press to set the sleep mode 2 Press and key to set your expected time for auto start or 3 Press key to turn on or off the air conditioner display 4 Press key At one press of this key the ic...

Страница 11: ...ake them out after 30s later and reinsert if they cannot normally run please change them Sketch map for changing batteries NOTE 1 Press swing button continuously more than 2seconds the main unit will...

Страница 12: ...f If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this signal Di...

Страница 13: ...oom temperature to select the COOL HEAT FAN mode automatically to obtain the comfortable effect At stopping When the unit is running press the ON OFF button of the manual switch the unit will stop wor...

Страница 14: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the figures a and b To clean the dust adhering to the...

Страница 15: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Страница 16: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Страница 17: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Страница 18: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Страница 19: ...n the local area Notices for installation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service...

Страница 20: ...should be connected in fixed wiring It should be reliably earthed and it should be connected to the special earth device the installation work should be operated by the professional The air switch mus...

Страница 21: ...ll Space to the wall Air outlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above e v o b A The dimensions of...

Страница 22: ...gh the hole Install the water drainage pipe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long dra...

Страница 23: ...wiring only Cut off the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through th...

Страница 24: ...on cable and the signal control wire Ensure wire has been fixed well Install the handle 5 1 0 10 pa 76cmHg 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low p...

Страница 25: ...in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely It may...

Страница 26: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Страница 27: ...inch Gas 9 52 3 8 12 1 2 12 1 2 16 5 8 16 5 8 inch Pipe tightening torque Liquid 20 20 20 20 20 m N Gas 35 55 55 65 65 Nm Quantity of refrigerant per metre of pipe over 5 m 20 20 20 50 50 g m A max 10...

Страница 28: ...500 mm D 150 mm E 300 mm 1178 253 L 776 848 mm 955 955 P 320 320 mm 424 424 H 540 540 mm 700 700 C 300 mm D 500 mm F 300 mm E 2000 mm Indoor unit net weight 10 kg 11 13 16 17 5 Outdoor unit net weight...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...5717310161 12 10 04 66129905672...