DeLonghi WIR2 Скачать руководство пользователя страница 9

Installation must include equipment shutoff
valve, union, and plugged 1/8” NPT tap.
Locate NPT tap within reach for test gauge
hook up. NTP tap must be upstream from
heater (see fig 7) 
IMPORTANT: install an equipment shutoff
valve in accessible location. The equipment
shutoff valve is for turning on or shutting off
the gas to the appliance.
Apply pipe joint sealant lightly to male NTP
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could
result in clogged heater valves.

Install sediment trap in supply line as shown in
fig. 7. Place sediment trap where it is within
reach for cleaning. Locate sediment trap
where trapped matter is not likely to freeze. A
sediment trap traps moisture and contami-
nants. This keeps them from going into heater
controls. If sediment trap is not installed or is
installed incorrectly, heater may not run prop-
erly.
IMPORTANT: hold the pressure regulator with
wrench when connecting it to gas piping
and/or fittings. Do not over tighten pipe con-
nection to regulator. The regulator body could
be damaged.

CHECKING GAS CONNECTIONS

1. Disconnect appliance with its appliances

main gas valve (control valve) and equip-
ment shutoff valve from gas supply piping
system. Pressures in excess of 1/2 psig will
damage heater regulator.

2. Cap off open end of gas pipe where

equipment shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve for
propane/LP gas or opening main gas
valve located on or near gas meter for nat-
ural gas, or using compressed air.

4. Check all joints of gas supply piping sys-

tem. Apply a non-corrosive leak detection
fluid to all joints. Bubbles forming show a
leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff

valve to gas supply. Check reconnected fit-
tings for leaks.    

9

WARNING: Use pipe joint sealant that is resist-
ant to liquid petroleum (LP) gas.

WARNING: test all gas piping and connections
for leaks after installing or servicing . Correct all
leaks at once.

WARNING: never use an open flame to check
for a leak. Apply a non-corrosive leak detection
fluid to all joints. Bubbles forming show a leak.
Correct all leaks at once. 
CAUTION: For propane/LP gas, make sure
external regulator has been installed between
propane/LP supply and heater. See guidelines
under connecting to Gas Supply, page 8.  

Pressure regulator

Regulator bracket

Heater cabinet

3/8" NPT pipe nipple

 Ground joint 
 union

 Equipment 
 shut off valve*

gas from gas meter 

3" minimum

Cap

Pipe 
nipple

Tee joint

Sediment 
trap

Reducer
bushing to
1/8" NPT 

Tee joint

Test gauge 
connection*

1/8" NPT 
plug tap

* A CSA design-certified equipment shutoff
valve with 1/8” NPT tap is an acceptable
alternative to test gauge connection. Purchase
the optional CSA design certified shutoff valve
from your dealer.

fig. 7

The appliance and its appliance main gas
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system pressures in excess of  
1/2 psi (3.5 Kpa).
The appliance must be isolated from the gas
supply piping system by closing its equip-
ment shut-off valve during any pressure
testing of the gas supply piping system at
test pressure equal to or less than 1/2 psi
(3,5 kpa).

GB  29-01-2004  16:33  Pagina 9

Содержание WIR2

Страница 1: ... suppli er WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxy gen from the room in which it is insta...

Страница 2: ...s heater Improper use of this heater can cause seri ous injury or death from burns fire explo sion electrical shock and carbon monoxide poisoning DANGER Carbon monoxide poisoning may lead to death WARNING Any change to this heater or its control can be dangerous WARNING Do not use any accessory not approved for use with this heater Due to high temperatures the appliance should be located out of tr...

Страница 3: ...sed or stored under dusty conditions 9 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the con trol system and any gas control which has been under water 10 Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater 11 Operating hea...

Страница 4: ...following ventilation classification 1 Unusually Tight Contruction 2 Unconfined Space 3 Confined Space The information on page 4 through 6 will help you classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must...

Страница 5: ...ly the space volume by 20 to deter mine the maximum Btu Hr the space can support ________ volume of space x 20 51 200 maximum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appli ances in the space Vent free heater ____________ Btu Hr Gas water heater ____________ Btu Hr Gas furnace ____________ ...

Страница 6: ...to the outdoors These spaces include attics and crawl spaces Follow the National Fuel gas Code ANSI Z223 1 NFA 54 section air for combustion and ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic has a thermostat con trolled power vent Heated air entering the attic will activate the power vent 6 WARNING if the area in w...

Страница 7: ...eat source If you have a central heating system you may run system s circulating blower while using heater This will help circulate the heat throughout the house In the event of a power outage you can use this heater as you primary heat source WARNING A qualified service person must install heater Follow all local codes WARNING maintain the minimum clearances shown in figure 4 if you can provide g...

Страница 8: ...gas pressure heater regula tor damage could occur Install the external regulator with the vent pointing down as shown in figure 6 Pointing the vent down pro tects it from freezing rain or sleet 8 WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator WARNING A qualified service person must connect heater to gas supply Follow all local codes WARNIN...

Страница 9: ...nat ural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply a non corrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fit tings for leaks 9 WARNING Use pipe joint sealant that is resist ant to liquid petroleum LP gas WARNING test all gas pip...

Страница 10: ...al gas open main gas valve locat ed on or near gas meter For propane LP gas open propane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve thermostat gas valve see figure 8 9 or 10 Apply a non corrosive leak detection fluid to all joints Bubbles form ing show a leak 5 Correct all leaks at once 6 Light heater see operating...

Страница 11: ...ollow the safety information If you don t smell gas go to the next step 5 Turn thermostat control knob counterclock wise to the pilot position Press in thermostat control knob for 5 seconds see fig 11 Note you may be running this heater for the first time after hooking up to gas supply If so you may need to press in control knob for 30 seconds or more This will allow air to bleed from the gas syst...

Страница 12: ...tion Shutting off heater Turn thermostat control knob clockwise to the OFF position INSPECTING HEATER Check pilot flame pattern and burner flame pattern often PILOT FLAME PATTERN Figure 13 shows a correct pilot flame pattern Figure 14 shows an incorrect pilot flame pat tern The incorrect pilot flame is not touching the thermocouple This will cause the thermo couple to cool When the thermocouple co...

Страница 13: ...16 shows a incorrect burner flame pattern If burner flame pattern is incorrect as shown in figure 16 turn heater off see to turn off gas to appli ance page 12 see troubleshooting pages 16 through 18 13 correct burner fig 16 fig 15 incorrect burner GB 29 01 2004 16 33 Pagina 13 ...

Страница 14: ...e the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot for dust and dirt 3 Blow air through the ports slots and holes in the burner 4 Never insert objects into the pilot tube Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly see figure 14 With the unit off light...

Страница 15: ...al numbers of your heater how heater was malfunctioning Type of gas used natural gas purchase date Usually we will ask you to return the defective part to the factory Heater ratings in british thermal units per hour BTUH Model Model Setting Input BTUH Type gas Pressure regulator setting Orifice Drill size n of radiators Inlet gas pressure inches of water LP GAS NAT GAS pilot ON pilot ON 400 13660 ...

Страница 16: ... combustion 1 Burner orifice is clogged or damaged 2 Low line pressure 3 Ods pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local natural gas company 3 Clean ODS pilot see cleaning and maintenace page 14 Gas odor even when con trol knob is in OFF posi tion 1 Gas leak See warning statement at top of page 2 Thermostat control valve defective 1 Locate and correct all l...

Страница 17: ...tion 1 Turn on gas supply or open equipment shutoff valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down control knob Repeat igniting opera tion until air is removed 4 Clean ODS pilot see cleaning and maintenance page 14 or replace ODS pilot assembly 5 Replace gas regulator 6 Turn control knob to pilot position When ignitor button is pressed in there is a spark...

Страница 18: ... odor dur ing initial operation 1 Residues from manufacturing processes 1 Problem will stop after a few hours of operation Heater produces whistling noise when burner is lit 1 turning control knob to HIGH position when burner is cold 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner ori fice 1 Turn control knob to LOW position and let warm up for a minute 2 ...

Страница 19: ...ce or accidents Also con sequential and incidental damages resulting from the use of this product or ari sing out of any breach of contract or breach of this warranty are not recoverable under this warranty Some states do not allow the exclusion or limitation of inci dental or consequential damages so the above limitation may not apply to you How Do You Get Service If repairs become necessary or s...