background image

25

ENGLISH

L10/ L15/ L20H operation

FAN MODE 

Adjust fan speed by pressing the 

FAN 

button (

P

) as described for the air-conditioning mode.

Remember that the higher the speed, the more air is filtered.  If you select "

Quiet

" speed, less air is

filtered but the appliance is also less noisy.
In this mode,

AUTO

cannot be selected.

The fan speed selected will be displayed.

HEATING MODE (MODEL L20H ONLY)

To set operation of the appliance correctly, press the “+” (

F

) or “-” (

I

) buttons until the desired tem-

perature is displayed.
In heating mode, the fan speed is selected automatically by the appliance.
The “

AUTO

” light (

O

) on the control panel comes on.

SETTING THE TIMER

The timer can be used to delay appliance start up or shut down.  This avoids wasting electricity by
optimising operating periods

How to programme delayed start up

Plug the appliance into a mains socket and press the

ON/OFF

(

A

) button, then select the requi-

red operating mode and other settings (temperature, fan speed, etc).

Press the ON/OFF (

A

) button again to place the appliance in standby mode.

Press the timer button (

Q

). The two centre segments flash on the display.

Use the “+” (

F

) o “-” (

I

) buttons to set the number of hours delay before the appliance comes

on. The setting is increased or decreased by an hour at a time; however, when the buttons are
held down for more than two seconds, the time runs rapidly up to a maximum of 24 hours. Wait
a few seconds for the data to be acquired.

The indicator light (

G

) flashes until the appliance starts up.

You can set the appliance to come on with a delay of up to 24 hours.
To cancel the timer setting, press the timer button (

Q

), and use the “-” button (

I

) to set the time to

zero. The indicator light (

G

) will stop flashing.

How to programme delayed shut down

Delayed shut down can be programmed in any operating mode (air conditioning / fan / hea-
ting) (model L20H only).

Press the timer button (

Q

). The two centre segments flash on the display.

Use the “+” (

F

) o “-” (

I

) button to set the number of hours delay before the appliance goes off.

The setting is increased or decreased by an hour at a time; however, when the buttons are
held down for more than two seconds, the time runs rapidly up to a maximum of 24 hours. Wait
a few seconds for the data to be acquired.

The indicator light (

G

) flashes until the appliance shuts down. 

To cancel the timer setting, press the timer button (

Q

), and use the “-” button (

I

) to set the time to

zero. The indicator light (

G

) will stop flashing.

Содержание Pinguino PAC L10

Страница 1: ...ources of heat Do not rest heavy or hot objects on top of the appliance Clean the anti microbial filters at least once a week Avoid using heating appliances near the air conditioning unit Always transport the appliance upright or resting on one side Use the appliance as described in this instruction manual only As with any electrical appliance while the instructions aim to cover as many eventualit...

Страница 2: ... in the home or be transported from one building to another Hot air from the room is passed through a coil cooled by refrigerant gas Excess heat and moisture are removed before the air is re emitted into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas and then when hot and damp is discharged outside In models with case Super Pinguino the circuit...

Страница 3: ...or French window Make sure the air exhaust hose is unob structed Open the window or French window sligh tly and position the outlet as shown in figure B 12 12 11 A Preparing for use B C Keep air hoses as short and free of cur ves as possible to avoid constrictions ELECTRICAL CONNECTIONS Before plugging the appliance into the mains socket check that the mains power supply corresponds to the value i...

Страница 4: ...ow pane Respect the height and dimensions of the hole given in figure E 30 cm 30 cm 106 MAX100 cm MIN 35 c When the hose is not fitted the hole can be closed with the flange cap NOTE When installing the air conditioning unit semi permanently you should leave a door slightly open as little as 1 cm to guarantee correct ventilation 10 11 in the window pane in the wall you are recommended to insulate ...

Страница 5: ...ode indicator light L20H only F Increase temperature programmed operating time button G Timer in operation indicator light H Display Displays the temperature values set and the programmed operating time I Reduce temperature humidity programmed operating time button L M N O Fan speed and AUTO mode indicator lights P Fan speed selection button Q Timer button B A C D E G H M I N O F Q P THE CONTROL P...

Страница 6: ... dehu midify the room To set the operation of the appliance correctly press the F or I buttons until the desired temperature is displayed Then select the fan speed by pressing the FAN button P until the indicator light corresponding to the required fan speed lights up MAX the air conditioning unit operates at maximum to reach the required temperature as rapidly as possible MIN reduces noise levels...

Страница 7: ...ay Use the F o I buttons to set the number of hours delay before the appliance comes on The setting is increased or decreased by an hour at a time however when the buttons are held down for more than two seconds the time runs rapidly up to a maximum of 24 hours Wait a few seconds for the data to be acquired The indicator light G flashes until the appliance starts up You can set the appliance to co...

Страница 8: ...obe is damaged FULL TANK The tank is full When the appliance is operating in air conditioning mode this device pre vents the formation of ice The appliance starts up again automatically when the defrosting process is completed If this alarm appears contact the service centre Empty the internal safety tank through the drain hoses see page 31 end of season operations WHAT SHOULD YOU DO ...

Страница 9: ...the receiver The remote control should be handled with extreme care and respect do not drop it expose it to direct sunlight or leave it near sources of heat DESCRIPTION OF THE REMOTE CONTROL 16 FAN button 17 ON OFF button 18 MODE button 19 TIMER button 20 Display THE REMOTE CONTROL Remove the cover on the rear of the remote control Replace the old batteries with two new 1 5V R03 AAA batteries inse...

Страница 10: ...h below the outside temperature FAN MODE ONLY In fan mode the fan speed can be set by pressing the FAN button 16 The fan speed changes between the speeds available LOW MED HIGH An arrow on the display indicates the set speed Remember that the higher the speed the more air is filtered If you select LOW speed less air is filtered but the appliance is also less noisy In this mode AUTO cannot be selec...

Страница 11: ...utton again to confirm the start up time A beep sounds and the timer light S on the control panel comes on to confirm the setting of the timer A countdown of the time left is displayed At the end of the set time the appliance switches on automatically with the settings made previously To cancel the set time press the TIMER button again a beep will sound and the light S on the control panel will go...

Страница 12: ...osure to the sun by partially closing curtains and or blinds to make the appliance much more economical to run Never rest objects of any kind on the air conditioning unit Never obstruct the air intake or outlet grilles Make sure there are no heat sources in the room 1 5 Never use the appliance in very damp rooms laundries for example Never use the appliance outdoors Tips close doors and windows cl...

Страница 13: ...rotating outwards Fig G Use a vacuum cleaner to remove the dust collected on the filter If it is very dirty immerse in warm water and rinse a number of times The water should never be hotter than 40 C After washing leave the filter to dry To replace put the filters back in the intake grille then attach the intake grille to the appliance START OF SEASON CHECKS Make sure the power cable and plug are...

Страница 14: ...nit works but does not cool the room window open there are heat sources in the room burner lamp etc the exhaust hose is detached air filters clogged the air conditioning unit is not powerful enou gh for the conditions or size of the room close the window eliminate the heat source connect the exhaust hose clean or replace the filters clean or replace the filter Particular odour in the room air filt...

Страница 15: ...ge see rating plate Max power input during air conditioning Max power input during heating mod L20H Refrigerant Cooling capacity Appliance dimensions width 505 mm height 825 mm depth 440 mm weight 34 kg Transport filling cleaning recovery and disposal of refrigerant should be performed by a tech nical service centre appointed by the manufacturer only The appliance should be disposed of by a specia...

Отзывы: