For technical reasons, the temperature is not expressed in degrees but by a line increasing in thickness.
We  therefore recommend that when starting up the appliance, the thermostat be turned to maximum
(Pos.“Coolest”). When the desired temperature has been reached move the thermostat slider slowly
away from the maximum cold position until the appliance is switched off by operation of the thermostat.
In this way the appliance has been programmed with the exact temperature degree required, which is
then maintained automatically by the thermostat

ON/OFF button

ON/OFF pilot light

“Alarm” pilot light

Timer ON/OFF
pilot light

Selecting fan
speed button

Timer ON/OFF

button

Thermostat

SETTING THE TIMER

The programmer/timer, like all clocks, must be set
to the exact time. If for example it is 4.00 p.m.,
turn the dial in a clockwise direction (following the
direction of the arrow) until the number 4 is lined
up with the arrow pointer (the arrows indicates
4:00 p.m. approximately).

Note

:Never turn the dial in an counter-clockwise

direction!

The timer is in effect, an electric clock and works
only if the plug is connected to the power supply.
Whenever the plug is disconnected or there is a
power failure, the programmer stops (the clock is
then “slow”) and must be re-set.

The unit can be used in either

programmed

or

non-programmed

mode.

PROGRAMMED MODE

1) Release B timer button
2) Set the operating times by pushing out the

notches on the dial corresponding to the peri-
od required (each notch represents 15 mins.).

3) Check that the timer indicates the correct time

(see instructions on setting).

4) Select the desired function as shown in the

chart overleaf.
The unit will now switch on and off each day
at the selected times and the Timer ON/OFF
pilot light will be on.

Note: To override the programmed operating
times, simply press the ON/OFF key.

NON-PROGRAMMED MODE

1) B TIMER button must be pressed
2) Select the desired function as shown in the

chart on the following page.

11

9

4

10

arrow pointer

11

10

9

4

Funzionamento

ex. from 9 to 11 a.m.

A

B

C

C o n t r o l   p a n e l

Operating time

PAC400  24-04-2003  16:29  Pagina 10

Содержание Pinguino PAC 400

Страница 1: ...PAC 400 PAC 400 Use and maintenance manual page 2 Mode d emploi et d entretien page 15 Instrucciones de uso p gina 28 Istruzioni per l uso pagina 41 PAC400 24 04 2003 16 29 Pagina 1...

Страница 2: ...onal injury Do not use outdoors This appliance must be connected to an efficient grounding sys tem Have your electrical system checked out by a qualified elec trician Do not use the appliance for othe...

Страница 3: ...mm depth 15 375 mm weight 44 kg Dimensions outdoor unit length 221 2 570 mm height 19 480 mm depth 10 260 mm weight 17 kg OPERATIONALAIR CONDITIONING LIMITS Room temperature 70 90 F 21 32 C Outside t...

Страница 4: ...AL UNIT EXTERNAL UNIT INTERNAL UNIT Carrying handle Removable filter Air intake grille Power cord storage Power cord Condensation drainage tube Castors feet Connection hose Control panel Timer Castor...

Страница 5: ...2 Eye hole screw 2 Sheathing frame 1 Castor stop 2 Drain connection for condensation with seal and two 4 2 penetrating screws 1 Castors for the external unit and washers 4 Support block for external...

Страница 6: ...nd the bracket fully within the window frame fit the bracket by turning the wing nut and lower the window onto the bracket after having passed the sheathing through the slot With the wing nut it s pos...

Страница 7: ...osen the shield s two self threading screws and disconnect the electric hook up unit The path of the connecting sheath should be as straight as possible without sharp curves or kinks To re connect the...

Страница 8: ...de 3 Attach the external unit to the bracket by means of the M6mm screws For temporary installation it is possible to hang the external unit as illustrated in the drawing In this case use the included...

Страница 9: ...w must be left partially open In order to insure low cost operations protect the room from direct sunlight by drawing the curtains and or by partially lowering or closing the shutters or blinds Do not...

Страница 10: ...es 4 00 p m approximately Note Never turn the dial in an counter clockwise direction The timer is in effect an electric clock and works only if the plug is connected to the power supply Whenever the p...

Страница 11: ...ance into the outlet Select the programmed or non pro grammed mode see previous page Select the fan speed required pressing Fan speed key C Turn the thermostat to Max Cold Press key A ON OFF ON OFF si...

Страница 12: ...ut an 8 increase in electrical consumption For this reason it is a good idea to clean the filter Remove the air filter as shown below Use a vacuum cleaner to remove the dust on the filter If the filte...

Страница 13: ...e safety float has switched the appliance off because the condensation tray inside the appli ance is full Remove the plug from the drainage tube and drain the con densation from the tray If this fault...

Страница 14: ...bligations or liabilities on our part We do not authorize any other person or company to assume for us any liability in con nection with the sale or use of our AIR CONDITIONER This warranty shall not...

Отзывы: