background image

11

VENTILATION/PURIFICATION

This is ideal for dusty or polluted areas; in effect, the appliance
recycles and purifies the air using the dust filters and 3M Filtrete™
electrostatic filters fitted. Adjust the fan speed by pressing the
“FAN” (Q) button, as illustrated in the air conditioning function.
Bear in mind that the higher the speed, the greater the volume
of air filtered; by selecting the “Silent” speed, less air is filtered, but
the noise level is low.
“AUTO” function cannot be selected in this mode.
The display will show the fan speed selected.

PROGRAMMING THE TIMER

The timer programs the appliance to switch on and switch off.
This will save electrical energy by optimizing the operating times. 
The timer is set using the b (F) or – (G); these increase and
decrease by one hour at a time, but if pressed for more than 2
seconds will automatically change the time more quickly, up to
a maximum of 24 hours.

How to set the delayed start function 

Connect the appliance to the mains supply and press
ON/OFF button: next, select the required operating mode
(temperature, fan speed etc.) 

Press the ON/OFF button again: the appliance will go into
stand-by mode.

Press the timer button (1): on the display the two central seg-
ments will start to flash.

Set the number of hours after which the appliance should
switch on, by pressing the + or – buttons.

The indicator (L) on the display will continue to flash until the
appliance starts operating.
The appliance can be programmed for up to 24 hours in advan-
ce.

How to set the delayed stop function

The appliance can be programmed for delayed stop from
any of the operating modes (air-conditioning/dehumi-
difying/purification/ventilation.

Press the Programmer button (1): on the display the two cen-
tral segments will start to flash.

Set the number of hours after which the appliance should
switch off by pressing the + or – buttons.

The indicator (L) on the display will continue to flash until the
appliance switches itself off. It will then go into Stand-by mode.

“Silent”

speed

“Min”

speed

“Max”
speed

25

O p e r a t i o n

GB  19-06-2003  9:09  Pagina 11

Содержание Pinguino FX160ECO

Страница 1: ...ar the unit The unit should be transported in a vertical position If this is not possible secure the unit at an angle do not lie horizontally Before transporting the unit drain the condensation collec...

Страница 2: ...even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas losing excess heat and moisture before being discharged again into the room In...

Страница 3: ...r intake grill 8 Rating plate 9 Water collection tank 10 Water drain tube 11 Stopper for drain tube 12 Power cord Description of the Accessories 13 Stopper and flange 14 Air exhaust hose 15 Air exhaus...

Страница 4: ...e 14 Place the air conditioning unit at a win dow or French window Open the window a little and position the attachment 15 as shown in fig 2 1 Setting up 2 3 Pinguino is equipped with an adjustable wi...

Страница 5: ...closed off with the flange stop per 12 N B When operating the appliance with semi per manent installation it is advisable to leave a door slightly ajar even only 1cm 0 4 to ensure free circulation of...

Страница 6: ...a ges due to failure in following normal safety procedures Replacement of the power cable must be carried out by qualified personnel THE DISPLAY A ON OFF Button B Function Button Air conditioning dehu...

Страница 7: ...eed by pressing the FAN button Q until the fan speed indicator appears MAX P if you want the maximum power of the air conditioner to reach the desired temperature as quickly as possi ble MIN O if you...

Страница 8: ...t function Connect the appliance to the mains supply and press ON OFF button next select the required operating mode temperature fan speed etc Press the ON OFF button again the appliance will go into...

Страница 9: ...re FULL TANK Empty the tank at the rear of the appliance and reposition correc tly THIS UNIT EMPLOYS AN EXCLUSIVE CON DENSATION RECYCLING SYSTEM TO DISPO SE OF EXCESS MOISTURE IN NORMAL CONDITIONS CON...

Страница 10: ...xchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air cond...

Страница 11: ...8 To remove the dust deposited on the anti bacterial filter use a vacuum cleaner If very dirty immerse in warm water not more than 40 C and rinse thoroughly Allow the filter to dry To replace fit the...

Страница 12: ...is set too high air filters are dirty the capacity of the air conditioner is not adequate for the conditions or the dimen sions of the room close the window eliminate source of heat set the thermostat...

Страница 13: ...p fuse If the plug is a moulded on type the fuse cover must be re fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be...

Страница 14: ...010500 06 03 D e L o n g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 f a x 3 9 0 4 2 2 4 1 3 6 4 7 w w w d e l o n g h i c o m GB 19 06 2003 9 09 Pagin...