O p e r a t i o n

SWITCHING THE APPLIANCE ON

Connect the appliance to the mains supply.
On the display two lines will appear indicating Stand-by mode

Press the ON/OFF button (

A

) and then the MODE button until the

relevant function indicator appears viz.:

Indicator C 

: air-conditioning

Indicator D

: dehumidifying

Indicator E

: purification/ventilation

AIR-CONDITIONING FUNCTION

This function is ideal in hot, humid weather conditions when the
atmosphere requires to be cooled and dehumidified.
To  ensure proper function of the appliance, after selecting the
air-conditioning function, press b (

F

) or – (

G

) until the desi-

red temperature appears on the display.

The temperatures most suited to the atmosphere in summer vary
between 24 and 27°C (75 and 80°F). We do not advise selection
of temperatures much lower than those outside.

Select fan speed by pressing the “FAN” button (

Q

) until the fan

speed indicator appears:
MAX (

P

): if you want the maximum power of the air-conditioner

to reach the desired temperature as quickly as possi-
ble.

MIN (

O

):  if you want to reduce the level of noise and still main-

tain a good level of comfort.

SILENT (

N

): when minimum noise is required,

AUTO (

M

):if you prefer the appliance to select the fan speed for

the temperature selected on the display panel.

DEHUMIDIFYING FUNCTION

This function is ideal for reducing humidity in the atmosphere
while avoiding increases or decreases in temperature (in
between seasons, damp places, wet spells of weather).
When you select the dehumidifying function, the letters “     ” will
appear on the display.

The water is collected in the tank at the rear of the appliance.
When the tank is full, the appliance will stop working and the
display will show the letters “     ” (Full Tank); the tank must then
be emptied. When it is re-inserted, the appliance will re-start
automatically. N.B. remove the air exhaust hose (13).

25

GB  19-06-2003  9:09  Pagina 10

Содержание Pinguino FX160ECO

Страница 1: ...ar the unit The unit should be transported in a vertical position If this is not possible secure the unit at an angle do not lie horizontally Before transporting the unit drain the condensation collec...

Страница 2: ...even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas losing excess heat and moisture before being discharged again into the room In...

Страница 3: ...r intake grill 8 Rating plate 9 Water collection tank 10 Water drain tube 11 Stopper for drain tube 12 Power cord Description of the Accessories 13 Stopper and flange 14 Air exhaust hose 15 Air exhaus...

Страница 4: ...e 14 Place the air conditioning unit at a win dow or French window Open the window a little and position the attachment 15 as shown in fig 2 1 Setting up 2 3 Pinguino is equipped with an adjustable wi...

Страница 5: ...closed off with the flange stop per 12 N B When operating the appliance with semi per manent installation it is advisable to leave a door slightly ajar even only 1cm 0 4 to ensure free circulation of...

Страница 6: ...a ges due to failure in following normal safety procedures Replacement of the power cable must be carried out by qualified personnel THE DISPLAY A ON OFF Button B Function Button Air conditioning dehu...

Страница 7: ...eed by pressing the FAN button Q until the fan speed indicator appears MAX P if you want the maximum power of the air conditioner to reach the desired temperature as quickly as possi ble MIN O if you...

Страница 8: ...t function Connect the appliance to the mains supply and press ON OFF button next select the required operating mode temperature fan speed etc Press the ON OFF button again the appliance will go into...

Страница 9: ...re FULL TANK Empty the tank at the rear of the appliance and reposition correc tly THIS UNIT EMPLOYS AN EXCLUSIVE CON DENSATION RECYCLING SYSTEM TO DISPO SE OF EXCESS MOISTURE IN NORMAL CONDITIONS CON...

Страница 10: ...xchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air cond...

Страница 11: ...8 To remove the dust deposited on the anti bacterial filter use a vacuum cleaner If very dirty immerse in warm water not more than 40 C and rinse thoroughly Allow the filter to dry To replace fit the...

Страница 12: ...is set too high air filters are dirty the capacity of the air conditioner is not adequate for the conditions or the dimen sions of the room close the window eliminate source of heat set the thermostat...

Страница 13: ...p fuse If the plug is a moulded on type the fuse cover must be re fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be...

Страница 14: ...010500 06 03 D e L o n g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 f a x 3 9 0 4 2 2 4 1 3 6 4 7 w w w d e l o n g h i c o m GB 19 06 2003 9 09 Pagin...

Отзывы: