background image

23

ENGLISH

D

uring the summer, optimum comfort is achieved with a temperature of between 24 and 27˚C

and about 50% relative humidity.

An air conditioner removes moisture and heat from the room where it is located. One advantage

of portable air conditioning units over fitted models is that they can be moved from one room to

another in the home or even transferred between different buildings.

The hot air in your room is passed through a coil

cooled by refrigerant gas, losing excess

heat and moisture before being

discharged again into the room.

In single unit models (Pinguino), a

small part of this air is used to

cool the refrigerant gas befo-

re, hot and moist air is being

discharged outside.

In suitcase models, the cir-

cuit is cooled using the air

outside.

ECO by Pinguino is the

latest generation of ecolo-

gical air conditioners. Pin-

guino does not contain

gases dangerous to the

earth's ozone layer

(CFC/HCFC).  In addition,

thanks to the extreme effi-

ciency of the appliance, not only

does it save you money on your

electric bills, but it saves the environ-

ment by not negatively contributing to

the greenhouse effect."

How does your Pinguino work

Содержание PINGUINO 70ECO

Страница 1: ...rant gases that may leak from the appliance do not remain in the room thereby causing a fire hazard This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres o...

Страница 2: ...ing excess heat and moisture before being discharged again into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas befo re hot and moist air is being...

Страница 3: ...C 18 Fix the window attachment to the end of the hose Place the unit near a window French win dow or door Open the window French window or door slightly and place the window attachment as shown in fi...

Страница 4: ...ough the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with the bung on the flange NOTE When the...

Страница 5: ...e water will also be used more quickly You may also use the airconditioner on air cooling only without filling the water tank If you only requi re the lower cooling power 16 8 A To open the front pane...

Страница 6: ...f the remote control When the remote control is not used it can be stored in the foreseen compartment To open the compartment press push 1 SLEEP TIM ER MODE SW I NG FAN SMART SUPE R Low Low High High...

Страница 7: ...or maximum comfort F SUPER button Starts or stops rapid cooling in the rapid cooling mode the fan operates at high speed with the temperature automatical ly set at 18 C G SLEEP button Sets or cancels...

Страница 8: ...ir conditioning dehumidifier fan or heater TIMER if the TIMER mode is selected the indicator lights remain on even when the appliance is off FORCED OPERATIONS This is a way of operating to be selected...

Страница 9: ...hazard When the remote control unit batteries are replaced the air conditioning indicator and heating indicator will flash alterna tely on the remote control unit liquid crystal display To set the re...

Страница 10: ...on A beep indicates that the air conditioning unit is on and the symbol flashes on the display Press the MODE button a number of times until the dehumidifying symbol appears on the display Use the but...

Страница 11: ...ning dehumidifying fan or SMART to be gradually reduced until it shuts down completely after eight hours To select SLEEP mode proceed as follows Press the button to turn the appliance on A beep indica...

Страница 12: ...l flashes Set the time when you want the appliance to go off using the buttons from 30 minutes to 24 hours Press the TIMER button again to confirm the selection A count down of the time left is displa...

Страница 13: ...ore A If you wish to use the purification filter Remove the purification filter from the filter housing Remove the aspiration grill fig F on page 36 and the dust filter which is atta ched to this Remo...

Страница 14: ...window to guarantee an adequate exchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do...

Страница 15: ...er draining off the water replace the drainage hose plug remove the dirt by scrubbing gently with a cloth where the tank is positioned START OF SEASON CHECKS Check that the power cable and socket are...

Страница 16: ...hour air conditioning function 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open and the a...

Страница 17: ...The unit works but does not cool the room a window is open in the room there is some source of heat lamp burner etc or there are many peo ple in the room the thermostat is set too high the air filter...

Страница 18: ...e fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fuse cover can be obtained from your ne...