I m p o r t a n t   s a f e g u a rd s

Use this appliance only as described in this instruction manual.
As with any electrical appliance, whilst the instructions aim to cover as many eventualities as
possible caution and common sense should be applied when operating and installing this air
conditioner.

This appliance has been manufactured to cool and de-humidify domestic environments and
should not be used for other purposes.

It is dangerous to alter or modify the unit's characteristics in any way.

The appliance must be installed in line with the relevant national legislation.

Should repairs be necessary, contact the nearest authorised Repair Service Centre. Unautho-
rised servicing can be dangerous.

This appliance is to be used by adults only; keep away from children.

In the case that the power cable becomes damaged, this must be substituted only by specialised
personnel authorised by the manufacturer.

Always ensure the appliance is earthed. If you have any doubts check with a qualified elec-
trician.

Avoid using extension leads with the unit.

Before cleaning or maintenance operations, always unplug the unit from the socket.

Do not pull on or place strain on the power cable when moving the appliance.

The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.

If the appliance is utilised in areas where there is no ventilation of air, it is necessary to take pre-
cautions to avoid that the refrigerant gases that may leak from the appliance do not remain
in the room, thereby causing a fire hazard.

This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres
or greater. 

The refrigerant gases R290 conform to EC regulations on the environment. Avoid perforating
the refrigerant circuit of the appliance.

•  Keep the unit at least 50 cm away from inflammable substances (alcohol etc) or pressurised con-

tainers (eg. aerosol cans).

Do not rest hot or heavy objects onto the appliance.

Clean the dust filter at least once a week.

Remember to perform the descaling procedure at the end of each season (see page 37).  In
areas where the water is particularly hard (rich in minerals), the use of a commercial anti-lime
product added to the water is recommended.  This can be requested from De’Longhi LTD.

Avoid using heaters near the unit.

Do not cover this appliance with bags when is not in use

Unventilated area where the appilance using flammable refrigerants is installed shall be  so con-
structed that any leaked refrigerants will not stagnate so as to cause a fire or an explosion hazard
caussed by igniting stagnant refrigerants from other source such as electric heater, stove and simi-
lar home applications.

The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie horizontally.
Before transporting the unit drain the condensation collecting-tray and tank. After transporta-
tion, wait at least 1 hour before switching on the unit.

The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.

Содержание PINGUINO 70ECO

Страница 1: ...rant gases that may leak from the appliance do not remain in the room thereby causing a fire hazard This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres o...

Страница 2: ...ing excess heat and moisture before being discharged again into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas befo re hot and moist air is being...

Страница 3: ...C 18 Fix the window attachment to the end of the hose Place the unit near a window French win dow or door Open the window French window or door slightly and place the window attachment as shown in fi...

Страница 4: ...ough the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with the bung on the flange NOTE When the...

Страница 5: ...e water will also be used more quickly You may also use the airconditioner on air cooling only without filling the water tank If you only requi re the lower cooling power 16 8 A To open the front pane...

Страница 6: ...f the remote control When the remote control is not used it can be stored in the foreseen compartment To open the compartment press push 1 SLEEP TIM ER MODE SW I NG FAN SMART SUPE R Low Low High High...

Страница 7: ...or maximum comfort F SUPER button Starts or stops rapid cooling in the rapid cooling mode the fan operates at high speed with the temperature automatical ly set at 18 C G SLEEP button Sets or cancels...

Страница 8: ...ir conditioning dehumidifier fan or heater TIMER if the TIMER mode is selected the indicator lights remain on even when the appliance is off FORCED OPERATIONS This is a way of operating to be selected...

Страница 9: ...hazard When the remote control unit batteries are replaced the air conditioning indicator and heating indicator will flash alterna tely on the remote control unit liquid crystal display To set the re...

Страница 10: ...on A beep indicates that the air conditioning unit is on and the symbol flashes on the display Press the MODE button a number of times until the dehumidifying symbol appears on the display Use the but...

Страница 11: ...ning dehumidifying fan or SMART to be gradually reduced until it shuts down completely after eight hours To select SLEEP mode proceed as follows Press the button to turn the appliance on A beep indica...

Страница 12: ...l flashes Set the time when you want the appliance to go off using the buttons from 30 minutes to 24 hours Press the TIMER button again to confirm the selection A count down of the time left is displa...

Страница 13: ...ore A If you wish to use the purification filter Remove the purification filter from the filter housing Remove the aspiration grill fig F on page 36 and the dust filter which is atta ched to this Remo...

Страница 14: ...window to guarantee an adequate exchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do...

Страница 15: ...er draining off the water replace the drainage hose plug remove the dirt by scrubbing gently with a cloth where the tank is positioned START OF SEASON CHECKS Check that the power cable and socket are...

Страница 16: ...hour air conditioning function 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open and the a...

Страница 17: ...The unit works but does not cool the room a window is open in the room there is some source of heat lamp burner etc or there are many peo ple in the room the thermostat is set too high the air filter...

Страница 18: ...e fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fuse cover can be obtained from your ne...

Отзывы: