Functions

SUPER MODE

SUPER mode is used to turn rapid cooling on or off. The fan is set to
high speed and the temperature is automatically set to 18°C.
To select SUPER mode, proceed as follows:

Press the        button to turn the appliance on. 

Press the SUPER button to set the mode. The         symbol is
displayed.

To go back to the previous mode, press the SUPER button
again.

PROGRAMMING THE TIMER

The timer can be used to delay appliance start up or shut down. 
This avoids wasting electricity by optimising operating periods.

Programming shut-down

With the air-conditioning unit on, press the TIMER button. The time
is displayed and the “h” symbol flashes. Set the time when you
want the appliance to go off using the          buttons (from 30
minutes to 24 hours).

Press the TIMER button again to confirm the selection. A count-
down of the time left is displayed.

At the end of the set time the appliance switches off automati-
cally. During the first ten hours, you can select half hour intervals.
For times greater than ten hours, one hour intervals can be selec-
ted.

To cancel the set time, press the TIMER button again. You will
hear a beep.

Programming start-up

With the air-conditioning unit off, press the TIMER button. The time
is displayed and the “h” symbol flashes. Set the time when you
want the appliance to come on using the         buttons (from 30
minutes to 24 hours).
During the first ten hours, you can select half hour intervals. For
times greater than ten hours, one hour intervals can be selected.

Press the TIMER button again to confirm the selection. 

At the end of the set time the appliance switches on automati-
cally.

To cancel the set time, press the TIMER button again. You will
hear a beep.

ENGLISH

Содержание PAC N120 HP

Страница 1: ...appliance Clean the dust filter at least once a week Avoid using heating appliances near the air conditioning unit Always transport the appliance upright or resting on one side with short movements o...

Страница 2: ...rant gas and then when hot and damp is discharged outside In split models the circuit is cooled using air from the outside All air conditioners can also be used in fan only mode DESCRIPTION OF THE APP...

Страница 3: ...units can also pass through a hole with a diameter of about 9 cm in an external wall The internal unit can be mounted permanently using the bracket accessory see mounting instructions provided with t...

Страница 4: ...figure 9 24 8 Disconnect the male and female cou plings by pushing the sleeve backwards and pulling Fig 10 To avoid damage to the couplings before passing the sheath through the hole in the wall you...

Страница 5: ...the same level as the indoor unit provided that the difference in level is not greater than 1 5m The air intake and outlet of the outdoor unit must be kept clear of obstacles Leave at least 6cm betwe...

Страница 6: ...operating mode is to be used only when the remote control is inoperative broken lost flat batteries Press the manual operation button until selecting the desired function air conditioning dehumi dify...

Страница 7: ...nvironment Warning Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechar geable nickel cadmium batteries Do not dispose of batteries in fire batteries may explode or leak...

Страница 8: ...B Buttons for SETTING THE ROOM TEMPERATU RE Set room temperature or program the timer C FAN button Sets fan speed to automatic high medium or low in sequence D SWING button not enabled on this model E...

Страница 9: ...EHUMIDIFYING MODE Activate this function when humidity is high Press the button to turn the appliance on Press the MODE button a number of times until the dehumidifying symbol appears on the display P...

Страница 10: ...an speed can not be selected even if they appear on the remote control display AUTOMATIC SLEEP MODE The automatic SLEEP mode is ideal for the night time as it enables operation of the air conditioning...

Страница 11: ...s Press the TIMER button again to confirm the selection A count down of the time left is displayed At the end of the set time the appliance switches off automati cally During the first ten hours you c...

Страница 12: ...of all liability ONE LAST LOOK AT THE ROOM To get the best from your air conditioning unit follow these recommendations close the windows and doors in the room to be air conditioned The only exceptio...

Страница 13: ...filters To clean the filters remove the dust filters from the intake grilles Fig 15 START OF SEASON CHECKS Make sure the power cable and plug are undamaged and the earth system is efficient Follow th...

Страница 14: ...service centre The remote control indicator is weak or inexistent flat batteries batteries inserted the wrong way round change the batteries check the polarity of the bat teries and The air conditioni...

Страница 15: ...rate 250 350 m3 h Dimensions of indoor unit width 450 mm height 475 mm depth 255 mm weight 10 kg Dimensions of outdoor unit width 660 mm height 542 mm depth 290 mm weight 30 kg Standard conditions In...

Отзывы: