background image

10

DESCRIPTION OF THE REMOTE CONTROL

D1. 

 ON/STAND-BY  button

D2. 

 MODE  button

D3. 

 Fan speed selection button  

D4. 

 Increase  button

D5. 

 Decrease  button

D6. 

 Timer  button

D1

D5

D2

D4

D6

D3

TURNING  THE  APPLIANCE  ON/OFF  USING  THE              

REMOTE CONTROL

•  Plug into the outlet.
•  Press the ON/STAND-BY button 

C1

C2

C4

C13

C12

C9

C7

C5

C6

C3

C14

C10

C15

C11

C8

 (D1). When turned on, 

the air conditioner starts operating in the same mode as 
when it was turned off.

•  Press the ON/STAND-BY button

C1

C2

C4

C13

C12

C9

C7

C5

C6

C3

C14

C10

C15

C11

C8

 (D1) again to switch the 

appliance off.

Please note:  

Never switch the appliance off by removing the plug. 

Always switch it off by pressing the 

C1

C2

C4

C13

C12

C9

C7

C5

C6

C3

C14

C10

C15

C11

C8

 ON/STAND-BY button (D1) 

and waiting few minutes before removing the plug. The appliance 
will only perform the standard checks if the appliance is switched 
off following this process. Pressing any button the remote control 
will automatically sync to the unit itself and whatever appears 
on the remote control display will now also appear on the unit 
display.

SELECTING THE OPERATING MODES

The operating modes available on the remote control through 
the MODE button (D2) correspond to those on the appliance 
control panel (C).

SELECTING THE TEMPERATURES

In air conditioning mode press    (D4) or     (D5) button to select 
the desired temperature.

SELECTING THE AIR FLOW                

button (D3)  

 to select the 

desired air flow.

The air flows available are:

Minimum air flow: 

when maximum quiet operation 

is desired.

Medium air flow

: when the noise level needs to be 

low but with a good comfort level.

Maximum air flow

: for maximum performance.

 

    

Auto  air  flow: 

the appliance automatically chooses 

the air flow based on the temperature selected and the 

environmental conditions. This selection is only avail-

able in air conditioning mode.

SELECTING THE TEMPERATURE SCALE 

 

The temperature can be displayed in °C or °F.  To change the tem-
perature unit of measure select the air conditioning mode then  
press both the decrease 

(D5) and  increase 

(D4)  keys for 

about 3 seconds.

SETTING THE TIMER

The timer allows the delayed start up or shut down of the appli-
ance. This function will prevent wasting electricity by optimizing 
the operating periods.

How to program delayed shut down

•  While the appliance is on in any operating mode, delayed 

shut down can be programmed.

•  Press the timer button 

C1

C2

C4

C13

C12

C9

C7

C5

C6

C3

C14

C10

C15

C11

C8

 (D6), the timer symbol is dis-

played and the hours light up.

•  Press the   (D5) and   (D4)

 

buttons until the desired 

number of hours to shut down appears on the display. 

A few seconds after the timer is set, the setting is acquired, the 

display shows the operating mode and the timer symbol stays lit.

Once the set time is elapsed, the air conditioner goes into standby.

To cancel the timer program, press the

C1

C2

C4

C13

C12

C9

C7

C5

C6

C3

C14

C10

C15

C11

C8

 timer button (D6) 

twice. The timer indicator will go off.

How to program delayed start up

•  Plug in the appliance and set to standby.

Press the timer button

C1

C2

C4

C13

C12

C9

C7

C5

C6

C3

C14

C10

C15

C11

C8

 (D6), the timer symbol is dis-

played and  the hours

 

light up.

Press the   (D5) and  (D4)

 

buttons until the desired 

number of hours to start up appears. Start up can be pro-

grammed at anytime within the next 24 hours.

When the set time is elapsed, the appliance will start to operate 

in the same operating mode that was previously set.

To cancel the timer program, press the 

C1

C2

C4

C13

C12

C9

C7

C5

C6

C3

C14

C10

C15

C11

C8

 timer button (D6) 

twice. The timer indicator will go off.

Note: 

• 

This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide reasonable protec-

D

In 

air conditioning

 and fan

 mode

s

 press 

Содержание PAC EM

Страница 1: ...oi Conservez cette notice Visitez www delonghi com pour y voir une liste des centres de r paration proches de chez vous CARACT RISTIQUES LECTRIQUES 115V 60 Hz SISTEMA DE AIRE ACONDICIONADO PORT TIL Re...

Страница 2: ...2 EN FR ES page 4 page 15 p g 27...

Страница 3: ...3 A1 A2 A7 A8 A10 A11 A9 A12 A3 A4 A13 B1 B3 B5 B4 B6 B6 B7 B2 B8 A5 A6 A B...

Страница 4: ...l on the power cord or appliance to detach the plug from the power outlet Do not move the appliance by pulling the power cable keeptheappliancefarfromthereachofchildren Do not insert foreign bodies in...

Страница 5: ...sed on the recommendations from the manufacturing company Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual spec...

Страница 6: ...otherwise re place the socket the socket is connected to an efficient grounding sys tem The manufacturer is not responsible in the event of non compliance with these injury prevention standards The po...

Страница 7: ...7 C5 C3 C4 C6 C C14 DESCRIPTION OF THE CONTROL PANEL C C1 ON STAND BY on off button C2 Mode selection key air conditioning dehumidifying fan C3 Decrease key C4 Increase key C5 Ventilation speed select...

Страница 8: ...utomatically chooses the best fanspeed based on the temperature selected and the environmental conditions Themostsuitabletemperaturesduringthesummerrangefrom75 to80 F 24to27 C However settingthetemper...

Страница 9: ...eandsettostand by 6 Press the timer button C the timer indicator C8 and hours light up Set with the buttons C3 or C4 the number after which you want the appliance to start to operate The appliance wil...

Страница 10: ...is only avail able in air conditioning mode SELECTING THE TEMPERATURE SCALE Thetemperaturecanbedisplayedin Cor F Tochangethetem perature unit of measure select the air conditioning mode then press bot...

Страница 11: ...Connect the equipment into an outlet on a circuit differ ent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications no...

Страница 12: ...r to remove any dust If it is very dirty sub merge it in warm water and rinse it several times fig 9 9 The water temperature must be kept below 104 F 40 C After washing the filter allow it to dry To r...

Страница 13: ...ring company The appliance must only be disposed by specialized per sonnel authorized by the municipality in which you live Attention TO AVOID DAMAGETOTHE UNIT NEVER TRANSPORT OR TURN THE APPLIANCE UP...

Страница 14: ...back of the appliance fig 1 filter clogged cleanorreplacethefilterasdescribedabove During operation there is an unpleasant smell in the room filter clogged clean the filter as described above The air...

Страница 15: ...N utilisez pas l appareil l ext rieur N obstruez pas les entr es et sorties d air Lorsquel appareilestbranch ausecteur gardez l esprit les r gles de s curit suivantes Ne touchez pas l appareil avec de...

Страница 16: ...l appareil Les gaz r frig rants peuvent tre inodores Cet appareil contient du gaz r frig rant R32 Pour plus de d tails sur le r frig rant voir la couverture arri re Nepercezaucunepartieducircuitder fr...

Страница 17: ...d air A9 C ble d alimentation lectrique A10 Tuyau d vacuation sup rieur avec bouchon A11 Tuyau d vacuation sup rieur avec bouchon A12 R cepteur du signal de la t l commande A13 Compartiment pour la t...

Страница 18: ...de l appareil fig 1 Selon les besoins placez les bandes de mousse autocollantes ou les bandes de mousse non autocollantes sur la fen tre comme indiqu dans la figure 2 Coupez les bandes de mousse auto...

Страница 19: ...minutes la luminosit de l cran diminue afin de r duire la consommation d nergie Remarque N teignez jamais le conditionneur d air en d branchant simplement la fiche de la prise Appuyez sur la touche a...

Страница 20: ...fourni B5 au tuyau d vacuation sup rieur A10 afin de per mettre l coulement de l eau dans un r cipient Retirer les bou chons ext rieurs ET int rieurs avant de raccorder le tuyau Voir Fig 6B Faites att...

Страница 21: ...oit d fini le r glage est enregistr L indicateur de minuterie reste allum et l cran revient en veille Pour effacer le programme de laminuterie appuyezdeuxfoissurlatoucheMinuterie C6 L in dicateur de m...

Страница 22: ...a tisation S LECTIONNER L UNIT DE MESURE DE TEMP RA TURE La temp rature peut tre affich e en C ou en F Pour modifier l unit de mesure de la temp rature s lectionnez le mode de climatisation puis appuy...

Страница 23: ...B NMB 3 B AUTO DIAGNOSTIC L appareil poss de un syst me d auto diagnostic permettant d identifier un certain nombre d avertissements dysfonctionnements Les messages d erreur s affichent sur l cran de...

Страница 24: ...ltre de la grille d admission d air A6 comme montr dans la figure 10 8 Utilisez un aspirateur pour enlever la poussi re S il est tr s sale plongez le dans de l eau chaude et rincez le plusieurs fois f...

Страница 25: ...tion L appareil ne doit tre limin que par du personnel sp cialis autoris par la municipalit o vous vivez Attention POUR VITERTOUT DOMMAGE L APPAREIL NE TRANSPORTEZ NI NE RENVERSEZ L APPAREIL L ENVERS...

Страница 26: ...ccorder le flexible d vacuation d air dans le logement l arri re de l appareil fig 1 filtre obstru nettoyer ou remplacer le filtre comme d crit ci dessus Pendant le fonctionnement l appareil mane une...

Страница 27: ...est conectado a la red el ctrica tenga en cuenta las siguientes normas de seguridad No toque el aparato con las manos mojadas o h medas No use el aparato descalzo o con los pies mojados No hale el cab...

Страница 28: ...ervicio ser realizado solo seg n las recomendaciones del fabricante El aparato debe almacenarse en un lugar seguro para prevenir el da o de la unidad Las personas que operen o trabajen en el circuito...

Страница 29: ...Salida de drenaje superior con tap n A11 Salida de drenaje inferior con tap n A12 Receptor de se al de control remoto A13 Compartimiento de control remoto Descripci n de los accesorios Consulte la p g...

Страница 30: ...ana de doble bisagra proceda de la siguiente manera Colocar la manguera de escape B1 en el recept culo co rrespondiente en la parte posterior del aparato fig 1 Dependiendodelanecesidad coloquelastiras...

Страница 31: ...ncendido apagado programado C13 Indicador velocidad auto ventilaci n C14 Indicador velocidad ventilaci n m n med m x APAGAR Y ENCENDER APARATO Antes de conectar el enchufe a la toma de corriente aseg...

Страница 32: ...x terna MODO DE DESHUMIDIFICACI N Estoesidealparareducirlahumedadenlahabitaci n primavera y oto o habitaciones muy h medas poca de lluvias etc Para este tipo de uso el aparato debe estar configurado d...

Страница 33: ...espera Pulse el bot n Temporizador C6 el s mbolo del tempori zador C8 y las horas se iluminan Ajuste con los botones C3 o C4 el n mero des pu s del cual quiere que el aparato empiece a funcionar El a...

Страница 34: ...de aire autom tico el aparato selecciona au tom ticamente el flujo de aire en funci n de la tem peratura seleccionada y las condiciones ambientales Esta selecci n est disponible solo en modo de aire a...

Страница 35: ...ferenciaenunainstalaci nenparticu lar Si este equipo causa interferencias perjudiciales para la recepci n de radio o televisi n lo cual puede determinarse apagandoyencendiendoelequipo serecomiendaalus...

Страница 36: ...illa de entrada y la rejilla se encuentra en la carcasa del filtro Para limpiar el filtro debe quitarse como se muestra en la figura 8 Luego remueva el filtro de la rejilla de entrada de aire A6 como...

Страница 37: ...a la limpieza la recuperaci n y la eliminaci n del refrigerante solo deben ser realizados por centros de servicio t cnico autorizados por la empre sa fabricante El aparato solo debe ser eliminado por...

Страница 38: ...la parte posterior del aparato fig 1 Filtro obstruido Limpie o reemplace el filtro como se ha descritoanteriormente Durante la operaci n hay un desagradable olor en la habitaci n Filtro obstruido Lim...

Страница 39: ...5715114361_00 _1120 Printed in China www delonghi com Gas charge Charge de gaz Carga de gas...

Отзывы: