background image

12

Using the remote control unit

DESCRIPTION OF THE REMOTE CONTROL

22) "ON/OFF"

button

23)

Temperature decrease/increase and

programme mode button

24) "MODE"

button

25) "TIMER"

button

26)

°F/°C switching button

27)

Fan speed button (MAX/MED/MIN)

Replacing the batteries

Remove the cover on the back of the

remote control;

Insert two new LR03 “AAA” 1.5V batteries,

making sure they are in the correct posi-

tion (see the instructions inside the battery

compartment);

Replace the cover.

TURNING THE APPLIANCE ON

Plug the appliance into the electrical receptacle.

Press the

ON/OFF

button of the remote control (

22

) (when turned on, the air conditioner starts

operating in the same mode as when last turned off).

Press the

MODE

button (

24

) button to select the required mode:

AIR CONDITIONING (COOLING)

DEHUMIDIFYING

HEATING

FAN ONLY

The light corresponding to the selected mode lights up on the control panel.

For air conditioning/dehumidifying/heating/fan only settings and programming the timer, see the

paragraphs on page 9 - 11.

If the remote control unit is replaced or discarded, the batteries must be removed and

disposed of in accordance with current legislation as they are harmful to the environment.

Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or recharge-

able (nickel-cadmium) batteries. Do not dispose of batteries in fire. Batteries may explode or

leak. If the remote control will not be used for a certain length of time, remove the batteries.

22
23

25

26

27

24

Note:

This equipment has been tested and found to comply with the limits for a Class B digital

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable

protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed

and used in accordance with the instructions, may cause harmful interference to radio

communications. However, there is no guarantee that interference will not occur in a partic-

ular installation. If this equipment does cause harmful interference to radio or television

reception, which can be determined by turning the equipment off and on, the user is

encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different from that to which the

receiver is connected.

- Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance

could void the user's authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two con-

ditions: (1) this device may not cause harmful interference, and (2) this device must accept any

interference received, including interference that may cause undesired operation.

This Class B digital apparatus complies with Canadian CAN ICES-3 (B) / NMB-3 (B).

Содержание PAC AN130HPE

Страница 1: ...5715111841_00 11 14 made in China www delonghi com...

Страница 2: ...CONDITIONNEUR D AIR PORTATIF PAC AN130HPE Instructions for use Keep these instructions Mode d emploi Conservez cette notice Enregistrez ce produit en ligne Visit www delonghiregistration com Visitez...

Страница 3: ...Description 1 5 8 4 7 3 9 2 6 10 12 19 13 14 15 16 17 18 20 21 ACCESSORIES ACCESSOIRES 11 19...

Страница 4: ...against fire Always ensure the appliance is plugged into a grounded 3 prong outlet If you have any doubts check with a qualified electrician We strongly discourage the use of an extension cord due to...

Страница 5: ...safety instructions absolves the manufacturer of all liability The power cable must be replaced by a qualified professional only DESCRIPTION 1 air outlet grille 2 control panel 3 handles 4 castors 5...

Страница 6: ...D Keep the air hoses as short and free of curves as possible to avoid constrictions French window After having screwed the window outlet into the air exhaust hose open the French window slightly and...

Страница 7: ...ose adaptor to the hose s end Fit the air exhaust hose in the housing at the back of the appliance as shown in figure A Screw the wall mount ing accessory into the hose fig H and fit it into the wall...

Страница 8: ...l H Dehumidifying symbol I Heating symbol L Fan symbol M Alarm symbol N Fan speed indicator O Temperature scale indicator P Time indicator Q Set temperatures room temperature and programmed on off tim...

Страница 9: ...on C until the required value is displayed During selection the temperature flashes After 10 seconds room temperature is displayed again Select the required fan speed by pressing the button There are...

Страница 10: ...ort Low speed for silent operation NOTE With particular room conditions e g low temperature or high temperature the appliance will automatically select the ope rating fan speed however If the unit is...

Страница 11: ...conditioning fan dehumidifying Press the timer button D The timer on symbol R comes on Use the F or C buttons to set the number of hours delay before the appliance goes off They increase or decrease t...

Страница 12: ...n length of time remove the batteries 22 23 25 26 27 24 Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These...

Страница 13: ...tilation Protect the room from direct exposure to the sun by partially closing curtains and or blinds to make the appliance much more economical to run Never rest objects of any kind on the air condit...

Страница 14: ...o remove the dust collected on the filter If it is very dirty immer se in warm water and rinse a number of times The water should never be hotter than 104 F 22 After washing the filter allow it to dry...

Страница 15: ...exhaust hose has a constriction the air exhaust hose is blocked there are bends in the air exhaust hose position the air exhaust hose correctly check there are no obstacles obstructing air discharge e...

Страница 16: ...uipped with a 3 prong grounded plug The plug must be connected into an outlet that is properly installed and grounded in the accordance with all local codes and ordinances Do not modify the plug provi...

Страница 17: ...abilities on our part We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR CONDITIO NER This warranty shall not apply to any AIR...

Отзывы: