INSTALLATION
The sheathing that connects the external to the
internal unit may pass:
a) through a slightly-open window or door;
b) through a small hole (5.5 cm x 2.5 cm) drilled
in the lower part of a door or in a window
frame by using the frame provided.
USE OF RAPID COUPLINGS
In addition to the methods described above, the
sheathing that joins the external to the internal unit
may also be drawn through a hole (about 6 cm. in
diameter) drilled in a wall linked to the outside.
In this case, the hook-ups with the external unit
must be disconnected as follows:
1) Remove the plug from the electric outlet;
2) Remove the handle by loosening the two
screws and then slipping off the facing.
3) Remove the U bolt by loosening the two
screws.
4) Remove the sheath stop by loosening the two
screws.
5) Using a 24-version wrench, unscrew the union
on the coupling. At the same time, hold the end
of the flexible tube tight by using a 21-version
wrench. Repeat this operation for the second
union using a 24- and a 19-version wrench.
6) Disconnect the condensation tube from the
rubber holder.
7) Loosen the shield’s two self-threading screws
and disconnect the electric hook-up unit.
The path of the connecting sheath should
be as straight as possible, without sharp
curves or kinks.
21
ø6
cm 30
SHEATH STOP
ELECTRIC
HOOK-UP
SHIELD
U BOLT