background image

14

CHECKS AT THE START OF THE SEASON

Ma e sure the power cable and soc et are in perfect condition 
and ma e sure the earthing system is e cient. Comply strictly 
with the installation standards.

END OF SEASON OPERATIONS

To drain all water from the circuit, remove the cap 

A11

 from the 

drainage on the bac  of the appliance and allow the water to 
drain out into a basin (fig. 10). 
To facilitate this operation, at the start of the season,  it’s possible 
to apply the water drain hose with cap  

B6

.

In order to properly storage the appliance at the end of the sea-
son, we suggest you cover it with the supplied end of season 
dust cover 

B8

 and you put the accessories in the relevant

end of season accessories bag

 B9

.

10

When the appliance is empty, replace the cap. 
Clean the filter and dry thoroughly before putting bac .

TECHNICAL SPECIFICATIONS

Power supply voltage                                          see rating label  
Max. absorbed power during air conditioning 

           “

Refrigerant 

                                    “

Cooling capacity 

          “

LIMIT CONDITIONS

Room temperature for 
air conditioning  

64 ÷ 95°F (18° ÷ 35°C)

Room temperature for 
heating 

50 ÷ 77°F  (10 ÷ 25°C)

Transport, filling, cleaning, recovery and disposal of 

refrigerant should be performed by a technical service 

centre appointed by the manufacturer only.

The appliance should be disposed of by a specialist centre 

appointed by the manufacturer only.

TO AVOID DAMAGE TO THE UNIT: 

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR 
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING 
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit 
has been on its side, oil needs to return to the compressor to en-
sure proper function.  Without allowing the unit this time (6-24 
hours) the unit may function for only a short time, and then the 
compressor will brea  down from lac  of oil. 

ELECTRICAL CONNECTION

This appliance is equipped with a 3 prong grounded plug. The 
plug must be connected into an outlet that  is properly installed 
and grounded in the accordance with all local codes and ordi-
nances. Do not modify the plug provided with the appliance. 
If it will not fit the outlet, have a proper outlet installed by a 
qualified electrician or relocate the unit to a proper outlet. If the 
household electrical supply does not meet the above specifica-
tions, or if you are not sure your home has an effective  electrical 
ground, have a qualified electrician or your local electrical utility 
company chec  it and correct any problems.

SAFETY PLUG

The appliance is fitted with a safety plug to protect the power 
cable. If power is cut off, unplug from the outlet and ma e sure 
the power cable is undamaged. If the cable is damaged, call the 
service center immediately. If power cuts off frequently and the 
power cable is undamaged, contact a qualified electrician.

OPERATION OF THE SAFETY PLUG

If the safety device incorporated in the plug trips and cuts off 
the power supply, chec  that the power cable and plug are not 
damaged. If the power cable is undamaged, to restore operation 
press the “RESET” button. To verify correct operation of the plug, 
press the “TEST” button periodically and ma e sure the appliance 
disconnects. If this is not the case, contact the service center. To 
restore operation, press the “RESET” button.

Содержание EL290 Series

Страница 1: ...mploi Conservez cette notice Visitez www delonghi com pour y voir une liste des centres de r paration proches de chez vous CARACT RISTIQUES LECTRIQUES 115V 60 Hz SISTEMA DE AIRE ACONDICIONADO PORT TIL...

Страница 2: ...2 EN FR ES pag 4 page 16 p g 28...

Страница 3: ...3 A B B1 B2 B3 B4 B8 B7 B6 B5 A4 A3 A2 A1 A7 A11 A9 A8 A6 B9 A5 A10 A12...

Страница 4: ...in on the power cord when moving the appliance The appliance should not be installed where the atmosphere may contain combustible gases oil or sulphur or near heat sources Donotresthotorheavyobjectson...

Страница 5: ...he outlet and electrical circuit are adequate for the appliance The outlet is a 3 hole grounded outlet If this is not the case you must choose another outlet Failure to follow these important safety i...

Страница 6: ...he appliance in stalled by specialized personnel AIR CONDITIONING WITHOUT INSTALLATION You can also set up in a double hung window Place the window brac et in the window sill extend the brac et fully...

Страница 7: ...48 US only 1 888 335 6644 Canada only or log onto our website at www delonghi com C5 C7 C8 C9 C6 C3 C4 C2 C1 C10 C11 C12 C13 C14 C15 C17 C16 C DESCRIPTION OF THE CONTROL PANEL C C1 ON STAND BY on off...

Страница 8: ...range from 75 to 81 F However setting the temperature significantly lower than the outdoor temperature is not recommended In conditioning mode the air flow can be selected only from the remote contro...

Страница 9: ...l the Real symbol appears After approx 1minute theREALFEELsymbol C16 changescolor whenapproachingthebestcomfortlevel seefollowingdiagram Perfect Perfect The well being feeling is a subjective conditio...

Страница 10: ...rts operating in the same mode as when it was turned off To switch the appliance off press button D1 Note Never switch the appliance off by removing the plug Alwaysswitchitoffbypushingthe buttonandwai...

Страница 11: ...G button D4 moves the flap evenly distributing the air into the room When the SWING button is pressed the flap will begin to move forwards and bac wards alternatively If pressed again the flap will be...

Страница 12: ...s Error messages are displayed on the appliance display IF IS DISPLAYED LowTemperature frostprevention WHAT SHOULD I DO The appliance is fitted with a frost protec tiondevicetoavoidexcessiveformationo...

Страница 13: ...ditioner with water Precautions Neverusepetrol alcoholorsolventstocleantheappliance Nev er spray insecticide liquids or similar CLEANINGTHE BIO SILVER AIR FILTER If fitted If the filter is dirty air...

Страница 14: ...OMMENDED After the unit has been on its side oil needs to return to the compressor to en sure proper function Without allowing the unit this time 6 24 hours the unit may function for only a short time...

Страница 15: ...ng in mind the recommendations for proper use there is some heat source in the room oven hair dryer etc eliminate the heat source the air exhaust hose is disconnected from the appliance attach the air...

Страница 16: ...le cordon d alimentation ni n appliquezdecontrainteslorsquevousd placez l appareil L appareil ne doit pas tre install l o l atmosph re peut contenir des gaz combustibles de l huile ou du soufre ou pr...

Страница 17: ...l La prise et le r seau lectrique conviennent l appareil La prise est une prise trois fiches reli e la terre Si cen estpaslecas vousdevezchoisiruneautreprise Lenon respect de ces instructions de s cur...

Страница 18: ...rons que vous fassiez installer l appareil par du personnel sp cialis CONDITIONNEUR D AIR SANS INSTALLATION Vous pouvez galement installer l appareil dans une fen tre guillotine Placez le support de f...

Страница 19: ...siteWeb au www delonghi com C5 C7 C8 C9 C6 C3 C4 C2 C1 C10 C11 C12 C13 C14 C15 C17 C16 C DESCRIPTION DU PANNEAU DE COMMANDE C C1 MARCHE VEILLE touche marche arr t C2 Touche de s lection de fonctions...

Страница 20: ...6 C Cependant il n est pas recommand de r gler la temp rature beaucoup plus bas que la temp rature ext rieure Enmodeconditionnement led bitd airnepeut tre s lectionn qu partir de la t l commande MODE...

Страница 21: ...mbole R el apparaisse Apr s env 1 minute le symbole SENSATION R ELLE C16 change de couleur l approche du meil leur niveau de confort voir diagramme suivant Perfect Perfect Lesentimentdebien treestunec...

Страница 22: ...yez sur le bouton D1 puis d branchez la prise Remarque N teignez jamais l appareil en d branchant la prise teignez le toujours en appuyant sur le bouton et en attendantquelquesminutesavantderetirerlap...

Страница 23: ...ppuyantunefois sur la touche de minuterie les heures restantes pour la mise en marche de l appareil s a cheront FONCTION ROTATION Le bouton de rotation D4 d place le volet en r partissant l air de man...

Страница 24: ...s a chent sur l cran de l appareil SI S AFFICHE Basse temp rature pr vention contre le gel QUE DEVRAIS JE FAIRE L appareil est quip d un dispositif de protection antigel afin d viter la for mation ex...

Страница 25: ...air avec de l eau Pr cautions N utilisez jamais de l essence de l alcool ou des solvants pour nettoyer l appareil Ne r pandez jamais de liquides insecticides ou autres NETTOYAGE DU FILTRE AIR BIO SILV...

Страница 26: ...Si l on ne laisse pas reposer l appareil pendant ce laps de temps 6 24 heures l unit peut fonctionner uniquement pendant une p riode courte puis le compresseur va tomber en panne par manque d huile RA...

Страница 27: ...les recommandations pour l utilisation Il y a une source de chaleur dans la pi ce four s che cheveux etc liminez la source de chaleur Leflexibled vacuationd airestd branch de l appareil Fixez le flexi...

Страница 28: ...re o ponga tensi n en el cable de alimentaci n al mover el aparato El aparato no debe ser instalado donde la atm sfera pueda contener gases combustibles aceite o azufre o cerca de fuentes de calor No...

Страница 29: ...te posterior del aparato La salida y circuito el ctrico son adecuados para el aparato La toma es una toma de tierra de 3 orificios Si este no es el caso debe elegir otra salida El incumplimiento de es...

Страница 30: ...sonal especializado AIRE ACONDICIONADO SIN INSTALACI N Tambi n se puede configurar en una ventana doble Coloque el soporte de ventana en el alf izar de la ventana extienda el soporte completamente den...

Страница 31: ...5 6644 Canad solamente O inicie sesi n en nuestro sitio web en www delonghi com C5 C7 C8 C9 C6 C3 C4 C2 C1 C10 C11 C12 C13 C14 C15 C17 C16 C DESCRIPCI N DEL PANEL DE CONTROL C C1 ENCENDIDO ESPERA Tecl...

Страница 32: ...blecer la temperatura significativamente me nor que la temperatura exterior no es recomendable Enmododeacondicionado elflujodeairepuedeserselecciona do solo desde el control remoto MODO DE DESHUMIDIFI...

Страница 33: ...l aparece Despu s de aprox 1 minuto el s mbolo REAL FEEL C16 cambia de color cuando se aproxima al me jor nivel de confort ver el siguiente diagrama Perfect Perfect El sentimiento de bienestar es una...

Страница 34: ...ismo modo que cuando fue desactivado Para apagar el aparato pulse el bot n D1 y a conti nuaci n quitar el enchufe Nota Nunca apague el aparato quitando el enchufe Siempre apagar pulsando sobre el bot...

Страница 35: ...la tecla temporizador solo una vez las horas restantes para encenderse aparecer n FUNCI N DE GIRO El bot n de giro D4 mueve la tapa de rejilla y distribuye de manera uniforme el aire en la habitaci n...

Страница 36: ...ror se muestran en la pantalla del dispositivo SI APARECE BajaTemperatura prevenci n de heladas QU DEBER A HACER El aparato est equipado con un dispo sitivo de protecci n contra congelaci n para evita...

Страница 37: ...e seguridad NUN CA lave el acondicionador de aire con agua Precauciones Nunca use gasolina alcohol o solventes para limpiar el aparato Nunca roc e insecticidas l quidos o similares LIMPIANDO EL FILTRO...

Страница 38: ...esor para asegurar su correcto funcionamiento Sin per mitir a la unidad este tiempo 6 24 horas la unidad puede fun cionars loporuncortoper ododetiempo yluegoelcompresor se descompone por falta de acei...

Страница 39: ...as recomendaciones para el uso correcto Hayalgunafuentedecalorenlahabitaci n microondas secador de pelo etc Eliminar la fuente de calor La manguera de escape de aire est desconectada del aparato Conec...

Страница 40: ...5715112711 11 17 Printed in China www delonghi com...

Отзывы: