GAS SUPPLY
■
The connection must be performed by an authorised person according to the relevant
standards.
■
Before connecting the appliance to the gas main, mount the brass conical adaptor
onto the gas inlet pipe, upon which the gasket has been placed (figs. 6a - 6b).
Conical adaptor and gasket are supplied with the appliance (packed with conversion
kit for use with Natural gas or ULPG).
■
This appliance is suitable for use with Natural Gas or ULPG. (Check the “gas type”
sticker attached to the appliance).
■
For Natural Gas models the gas supply is connected to the pressure regulator which is
supplied with the appliance (fig. 6b). Adjust the regulator to obtain a test point pressure
of 1 kPa with the two semi-rapid (SR) burners operating at maximum.
■
For ULPG models the gas supply is connected to the test point adaptor which is sup-
plied with the appliance (fig. 6a) and ensure that the supply pressure is regulated to
2.75 kPa.
■
The connection must be made at the rear of appliance (left or right); the pipe does not
cross the cooker (fig. 7).
■
The inlet not used must be closed off with the cap and sealing gasket supplied.
■
IMPORTANT: Use two spanners to tighten or loosen the connecting pipe (fig. 8).
Gas connection for
ULPG
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Test point adaptor
Test
point
Gas connection for
NATURAL GAS
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Test
point
Figure 6a
Figure 6b
Содержание DEF608GW
Страница 2: ...2...
Страница 35: ...35 S F C T A B T S Figure 26a Figure 26b Figure 26c Figure 25a Figure 25b...