DeLonghi DEC12-14 Скачать руководство пользователя страница 3

14

I

mportant

• Use this appliance only as described in this instruction manual.

As with any electrical appliance, whilst the instructions aim to cover as many eventualities as possible cau-
tion and common sense should be applied when operating and installing this air conditioner.

• This appliance is designed to dehumidify domestic rooms and must not be used for other purposes.
• In the case that the power cable becomes damaged, this must be substituted only by specialised person-

nel authorised by the manufacturer.

•  It is dangerous to modify or alter the characteristics of the appliance in any way.
• If the appliance requires repair, always contact a Technical Service Centre authorised by the manufactu-

rer. Always insist on original spare parts. Repairs carried out by unauthorised personnel may be dangerous
and invalidate the guarantee.

• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly

qualified persons  in order to avoid a hazard.

•  This appliance must be used exclusively by adults. Children should not be allowed to play with this appliance.
• Children should not be allowed to play with this appliance.
•  The appliance must be connected to an efficient earth installation. Have your electrical circuit checked by

a qualified electrician.

•  Do not use extension power cables.
•  Before cleaning or maintenance operations, always unplug the appliance from the mains.
•  Do not move the appliance by pulling the power cable.
•  Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.
•  Do not use the appliance on inclined surfaces.
•  Keep the unit at least 50 cm away from inflammable substances (alcohol etc) or pressurised containers

(eg. aerosol cans).

•  Do not rest heavy or hot objects on top of the appliance.
•  Clean the air filter regularly.
•  Always transport the appliance upright or resting on one side. Remember to drain the tank before moving

the appliance. Wait at least 1 hour after transporting the appliance before starting it

•  R134a is a refrigerant that complies with the EEC environmental standards; nonetheless, the refrigerant cir-

cuit on the machine should not be perforated. At the end of its working life, consign the appliance to a spe-
cial collection centre.

•  The materials used for packaging can be recycled. You are therefore recommended to dispose of them in

special differentiated waste collection containers.

• The appliance must be installed in conformity with the relevant national legislation.
• Do  not use the appliance outdoors.
• Do not obstruct the air intake or outlet.

T

echnical assistance

Keep the list of Technical Service Centres and identify the Centre nearest you.

E

lectrical connections

After moving the appliance, wait at least an hour before turning it on again.

Before plugging the appliance into the power socket, check that:
• The mains power supply corresponds to the power supply indicated on the rating plate.
•  The power socket and electrical circuit are adequate for the appliance.
• The power socket matches the plug. If this is not the case, have the plug replaced by a qualified electrician;
•  The power socket must be adequately earthed;

Failure to respect this safety rule absolves the manufacturer from all  liability.
This appliance is manufactured in compliance with EEC standard EN 55014 on the suppression of radio
interference.

• The cable must be replaced by approved service personnel only.

I m p o r t a n t

Содержание DEC12-14

Страница 1: ...than 10 C for prolonged periods low level heating will be necessary to allow the condensate to evaporate into the air before dehumidification can take place The air will however be slightly warmed by...

Страница 2: ...sate drain hose some models only rubber bung DEC12 14 DEC18 2 1 1 Control panel 2 Control panel cover 3 Air outlet grille 4 Condensate collection tank 5 Lifting handle 6 Air intake grille 7 Electrosta...

Страница 3: ...urfaces Keep the unit at least 50 cm away from inflammable substances alcohol etc or pressurised containers eg aerosol cans Do not rest heavy or hot objects on top of the appliance Clean the air filte...

Страница 4: ...The condensate can be drained directly into the tank located inside the appliance fig 2 The tank can be easily removed and has a handle making it simple to carry and empty B Continuous external drain...

Страница 5: ...tion knob 1 Plug the appliance into a mains socket 2 Check that the tank full tank missing light is off 3 Select the or or the dehumidification standby light switches on in the first 3 minutes safety...

Страница 6: ...rifies in all the other dehumidification functions Low consumption dehumidification function When the set humidity level in the room is reached the appliance stops In cases where dehu midifying is req...

Страница 7: ...appliance is effectively dehumidifying if the humidity in the room is already low enough the light will be off Dehumidification standby low temperature operation light The light switches on in the fo...

Страница 8: ...atically you are recommended to clean the filter once a week To remove the air filter extract by pulling it as shown in fig 5 Use a vacuum cleaner to remove dust accumulations from the filter If the f...

Страница 9: ...oo low room too large too many sources of humi dity in room boiling pots etc plug into the mains check the power supply turn the humidistat to the max position empty the tank gently place the tank in...

Страница 10: ...d power Maximum absorbed current Defrosting device yes Humidistat yes Fan speeds 1 2 Air filter yes Purifying filter no yes Dimensions LxHxP 570x360x300mm Tank capacity 4 liters Operating limits Dehum...