background image

18

W

arnings

-

Use this appliance only as described in this instruction manual. As with any electrical applian-

ce, whilst the instructions aim to cover as many eventualities as possible caution and common
sense should be applied when operating and installing this appliance.

-  The appliance must be installed according to the legislation on electrical systems in force in

each country.

-

If the power cable is damaged, it must only be replaced by specialist personnel.

-  This appliance is designed to dehumidify residential environments and must not be used for

other purposes.

-  It is dangerous to modify or alter the characteristics of the appliance in any way.
-  If the appliance requires repair, always contact a Service Centre authorised by the manufactu-

rer. Always insist on original spare parts. Repairs carried out by unauthorised personnel may be
dangerous and invalidate the guarantee.

-  This appliance must be used exclusively by adults. Do not allow children to play with the applian-

ce.

-  The appliance must be connected to an efficient earth system. Have your electrical circuit

checked by a qualified electrician.

- Do not use extension cords.
-  Before cleaning or maintenance operations, always unplug the appliance from the power

socket.

-  Do not move the appliance by pulling the power cable.
-  Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of

heat.

-  Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressuri-

sed containers (e.g. aerosol cans).

- Do not rest heavy or hot objects on top of the appliance.
-

Clean the air filter regularly.

-  Always transport the appliance upright or resting on one side. Remember to drain the tank befo-

re moving the appliance. 

-  R134a is a refrigerant that complies with the EEC environmental standards; nonetheless, the refri-

gerant circuit in the appliance should not be perforated. At the end of its working life, consign
the appliance to a specialist collection centre. 

-  The materials used for packaging can be recycled. You are therefore recommended to dispo-

se of them in special differentiated waste collection containers.

T

echnical service

Keep the list of Service Centres and identify the Centre nearest you.

E

lectrical connections

After moving the appliance, wait at least an hour before turning it on again.

Before plugging the appliance into the power socket, check that:
-  The mains power supply corresponds to the power supply indicated on the rating plate.
-  The power socket and electrical circuit are adequate for the appliance.
-  The power socket matches the plug. If this is not the case, have the plug replaced by a qualified elec-

trician;

-  The power socket is adequately earthed.

W a r n i n g s

5748011200DE350E/GB  21-01-2004  10:49  Pagina 18

Содержание DE 350E

Страница 1: ...lso another method used to lower relative humidity that is increase the ambient tem perature It is like increasing the capacity of the tank Therefore air at 20 C acts like a 10 litre tank while air at...

Страница 2: ...of excess humidity such as kitchens bathrooms laundries basements etc Combined operation is perfect for drying clothes COMBI function Carefully read this instruction booklet before installing and usin...

Страница 3: ...r bung 1 17 ENGLISH Description Accessories 1 2 Air inlet Air outlet 3 4 5 6 7 1 Control panel cover 2 Control panel 3 Tank door 4 Condensate collection tank 5 Air intake grille 6 Air filter 7 Lifting...

Страница 4: ...g the power cable Do not install the appliance in rooms containing gas oil or sulphur Do not install near sources of heat Keep the appliance at least 50 cm away from flammable substances alcohol etc o...

Страница 5: ...ded to use the continuous drain facility 1 Remove the rubber bung from the spout 2 Drill the inside of the drain spout using a narrow drill bit Fig 2 3 Fasten the rubber hose to the spout To do this o...

Страница 6: ...on Hygrometer thermostat button Humidity percentage indicator light Display Timer ON indicator light ON OFF button Increase humidity temperature hours button MODE button Turbo Power button Timer butto...

Страница 7: ...ay be shown on the display 1 Indicates that the appliance is in Standby mode 2 tP Indicates that the appliance is operating in TURBO POWER mode 3 Ft Indicates that tank is not fitted is full or is pos...

Страница 8: ...at the timer function is active Dehumidifying indicator light Indicates that the appliance is operating in dehumidification mode Heating indicator light Indica che l apparecchio sta funzionando in mod...

Страница 9: ...to indicate that the appliance is in standby and therefore ready for operation If the message FT is displayed empty the tank or position it correctly 3 Press the ON OFF button 4 Press the mode button...

Страница 10: ...of excess temperature while still gua ranteeing the dehumidification function The appliance resumes heating operation as soon as the temperature falls back below the maximum value The display shows t...

Страница 11: ...n the mains lead are coloured in accordance with the fol lowing code Green and yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead may not correspond with the coloured m...

Страница 12: ...humidity set point close the windows to resume operation swit ch the appliance off for a few minutes eliminate the cause of the overheating then switch the appliance back on If the problem persists c...

Страница 13: ...filter yes Dimensions WxHxD 365x610x360 mm Weight net 21 5 kg Tank capacity 5 5 litres Operating limits Heating Dehumidification temperature Max 27 C 5 32 relative humidity Max 90 30 95 Note The quant...

Отзывы: