![DeLonghi CLIMAVENETA HED HCAT 0011 SE Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/delonghi-0/climaveneta-hed-hcat-0011-se/climaveneta-hed-hcat-0011-se_installation-and-service-manual_2469227011.webp)
HED-HCAT SE FREE COOLING
ENGLISH
9
GENERAL TECHNICAL DATA
A
I
ELECTRIC HEAT ELEMENT POSITIONING
A
I
0011-002
1-0031
0041-0051-0061
Electric heat element kW 1,5 3
0011-0021 0031 0041-0051 0056-0061
Total Cooling capacity kW 4,7-6,0 7,3 9,0-11 13,8-15,2
Sensible Cooling Capacity kW 4,4-5,5 6,5 8,7-10,6 13,4-14,0
Unit power supply
V-Ph-Hz
230-1-50
*
400-3-50 400-3-50
Compressor absorbed power kW 1,20-1,60 1,7 2,8 3,3-4,4
Evaporator air flow rate l/s 460 500 650 950
Allowed minimum air flow rate in Free-Cooling
l/s
415
450
600
850
Evaporator fan absorbed power kW 0,20 0,20 0,45 0,9-1,0
Condenser air flow rate l/s 700 700 1100 1360-1500
Condenser fan absorbed power kW 0,18 0,18 0,25 0,25-0,70
Heater power
kW
1,50
1,50
3-6
3-6
Max. external operating temperature
°C
48
48
48
48
Min. external operating temperature
°C
-20
-20
-20
-20
External reference temperature
°C
35
35
35
35
Internal reference temperature
50 %UR
+27 °C
+27 °C
+27 °C
+27 °C
Free field external sound pressure at 1 m from the machine dBA
53
56
56
58
Free field external sound pressure at 1 m from the machine silented version dBA - LNV 46 48 51 53
(*)
230-1-50/400-3-50
(1) Data measured under the following conditiong : 27°C, 47% U.R. indoor, 35°C outdoor; nominal power
(2) Measured at outdoor temperature of 35°C, at 1 metre in open field.
(3) Maximum outdoor temperature referred to internal tempearature of 24°C.
Содержание CLIMAVENETA HED HCAT 0011 SE
Страница 2: ...2...
Страница 13: ...11 HED HCAT SE FREE COOLING ENGLISH ELECTRICAL PANEL LAYOUT I A...
Страница 44: ...42 HED HCAT SE FREE COOLING ENGLISH...
Страница 45: ......
Страница 46: ...Via L Seitz 47 310100 Treviso Italia Tel 0422 4131 Telefax 0422 413659 www delonghi com GRUPPO...