FEATURES 
 

 

6% to 40% moisture range for reed 

 

For use on plywood and chipboard  

 

Digital readout 

 

Built-in calibration check  

 

Temperature stable circuit 

 

Averages up to 100 accumulated readings 

 

Displays average and highest of accumulated readings 

 

Ergonomic case design 

 

Includes (1) 9-volt battery 

 

Three year warranty  

 

Over 65 years of proven quality, accuracy and service 

 
 
 
 

BEFORE YOU BEGIN 

 
BUTTON FUNCTIONS 
 

                 Read (#1):     Reads the percent moisture content value %MC. 
 

 

 

 

Calibration  

 

Check (#2) 

Checks the meter calibration. Displays the average of up to 100 
accumulated readings; displays the highest  

                  

 stored reading; erases the readings 

 

 

 

 

Set Point  

 

Decrease (#3): Acts as an arrow button when pressed after the set-point button 

to decrease the set point to a lower value. 

 
 

            Set-Point (#4):  Displays the current set-point.  Also acts as an arrow (scroll) 

button to increase the set-point value in 1% increments. 

 

  

When the battery is replaced, the meter displays its software version for 
one second and then turns itself off.  After replacing the battery, you 
must reset the meter as described below in the “Resetting the Meter” 
section.  
 
NOTE, we recommend NOT to use a rechargeable battery and advise to 
only use ‘ALKALINE’ batteries. 

 

Содержание F-2000R

Страница 1: ...F 2000R REED MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...

Страница 2: ...ng A Reading 6 Testing Reed stems 6 Testing in Roofing sheets 6 Factors Affecting Your Reading 6 Range Of Moisture Content 7 Reed Temperature 7 Curing 7 Density 7 Use Of Preservatives 8 In general 8 C...

Страница 3: ...ibration Displays the average of up to 100 accumulated readings displays the highest stored reading erases the readings Set Point Decrease 3 Acts as an arrow button when pressed after the set point bu...

Страница 4: ...e the button to stop at your desired set point If the meter reads a MC higher than that of the set point a buzzer will sound TO CHECK THE ACCUMULATED READINGS This feature allows you to view the total...

Страница 5: ...1235 to the external connector on the top of the meter Insert the electrode into the reed bundle Press the read button 1 The meter displays the MC for two seconds NOTES The reed electrode is electrica...

Страница 6: ...the electrical meter readings the indicated moisture content should not be used as an absolute quantitative measurement Meter readings are very useful guidelines for safe use of reed Meter readings b...

Страница 7: ...en on different parts of the bundle The higher the moisture range the wider are the variations The more curing has been allowed to take place the greater uniformity in moisture distribution can be exp...

Страница 8: ...ations among readings are greater If there is a possibility of high moisture areas samples from these locations should be taken Areas of high moisture content will spoil resulting in loss It is extrem...

Страница 9: ...prepaid We are not responsible for damage in transit We do not accept COD shipments or cover any incoming freight or duty charges on returned merchandise Turnaround time on repairs is approximately t...

Страница 10: ...MHORST be liable for any incidental indirect special or consequential damages of any type whatsoever including but not limited to lost profits or downtime arising out of or related in any respect to t...

Страница 11: ...Directive Standard s to which Conformity is declared EN 50082 1 1992 EMC Generic immunity standard EN 50081 1 1992 EMC Generic emission standard EN 55011 1991 Limits and methods of measurement of radi...

Страница 12: ...12...

Отзывы: