F-2000R
REED MOISTURE METER
OPERATION MANUAL
DELMHORST EUROPE
TITANIUMLAAN 100
NL 5221 CK ‘s-HERTOGENBOSCH
THE NETHERLANDS
[email protected]
www.MoistureMetersDelmhorst.com
+31 (0)73 6395080
Страница 1: ...F 2000R REED MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...
Страница 2: ...ng A Reading 6 Testing Reed stems 6 Testing in Roofing sheets 6 Factors Affecting Your Reading 6 Range Of Moisture Content 7 Reed Temperature 7 Curing 7 Density 7 Use Of Preservatives 8 In general 8 C...
Страница 3: ...ibration Displays the average of up to 100 accumulated readings displays the highest stored reading erases the readings Set Point Decrease 3 Acts as an arrow button when pressed after the set point bu...
Страница 4: ...e the button to stop at your desired set point If the meter reads a MC higher than that of the set point a buzzer will sound TO CHECK THE ACCUMULATED READINGS This feature allows you to view the total...
Страница 5: ...1235 to the external connector on the top of the meter Insert the electrode into the reed bundle Press the read button 1 The meter displays the MC for two seconds NOTES The reed electrode is electrica...
Страница 6: ...the electrical meter readings the indicated moisture content should not be used as an absolute quantitative measurement Meter readings are very useful guidelines for safe use of reed Meter readings b...
Страница 7: ...en on different parts of the bundle The higher the moisture range the wider are the variations The more curing has been allowed to take place the greater uniformity in moisture distribution can be exp...
Страница 8: ...ations among readings are greater If there is a possibility of high moisture areas samples from these locations should be taken Areas of high moisture content will spoil resulting in loss It is extrem...
Страница 9: ...prepaid We are not responsible for damage in transit We do not accept COD shipments or cover any incoming freight or duty charges on returned merchandise Turnaround time on repairs is approximately t...
Страница 10: ...MHORST be liable for any incidental indirect special or consequential damages of any type whatsoever including but not limited to lost profits or downtime arising out of or related in any respect to t...
Страница 11: ...Directive Standard s to which Conformity is declared EN 50082 1 1992 EMC Generic immunity standard EN 50081 1 1992 EMC Generic emission standard EN 55011 1991 Limits and methods of measurement of radi...
Страница 12: ...12...